Cited by 140Tactile and Sensory InteractionsMotor Control and AdaptationMuscle activation and electromyography studies

Cutaneous afferents provide a neuronal population vector that encodes the orientation of human ankle movements

Open access
Aimonetti, Jean‐Marc, Hospod, Valérie, Roll, Jean‐Pierre, Ribot‐Ciscar, Edith·2007·The Journal of Physiology

Abstract

The aim of this study was to analyse the directional coding of two‐dimensional limb movements by cutaneous afferents from skin areas covering a multidirectional joint, the ankle. The activity of 89 cutaneous afferents was recorded in the common peroneal nerve, and the mean discharge frequency of each unit was measured during the outward phase of ramp and hold movements imposed in 16 different directions. Forty‐two afferents responded to the movements in the following decreasing order (SA2, n= 24/27; FA2, n= 13/17; FA1, n= 3/24; SA1, n= 2/21). All the units activated responded to a specific range of directions, defining their ‘preferred sector’, within which their response peaked in a given direction, their ‘preferred direction’. Based on the distribution of the preferred directions, two populations of afferents, and hence two skin areas were defined: the anterior and the external lateral parts of the leg. As the directional tuning of each population was cosine shaped, the neuronal population vector model was applied and found to efficiently describe the movement direction encoded by cutaneous afferents, as it has been previously reported for muscle afferents. The responses of cutaneous afferents were then considered with respect to those of the afferents from the underlying muscles, which were previously investigated, and an almost perfect matching of directional sensitivity was observed. It is suggested that the common movement‐encoding characteristics exhibited by cutaneous and muscle afferents, as early as the peripheral level, may facilitate the central co‐processing of their feedbacks subserving kinaesthesia.

Integrity signals

Registry

Crossref · 10.1113/jphysiol.2006.123075

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • For the foot dorsum and leg, our sample included 315 afferents, 47% of which were slowly adapting.

    “For the foot dorsum and leg, our sample included 315 afferents, 47% of which were slowly adapting (Aimonetti et al. 2007;Edin 2001;Nagi et al. 2019;Ribot-Ciscar et al. 1996, 1989;Trulsson 2001).”

    From Tactile innervation densities across the whole body (2020) · cites this paper as Aimonetti et al. 2007

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Aimonetti, J., Hospod, V., Roll, J., & Ribot‐Ciscar, E.
Affiliations
Centre National de la Recherche Scientifique (FR)
Venue
The Journal of Physiology
Publisher
Wiley
Published
2007-04-10
Volume
580
Issue
2
Pages
649-658
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2135552149
Cited by
140
References
1
Citations by year
2026: 4 · 2025: 6 · 2024: 2 · 2023: 13 · 2022: 8 · 2021: 9 · 2020: 9 · 2019: 7 · 2018: 7 · 2017: 7 · 2016: 8 · 2015: 12 · 2014: 5 · 2013: 11 · 2012: 11
FWCI
2.84
Type
journal article
Language
en
Open access
Locations
  • The Journal of Physiology (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
  • HAL (submittedVersion)
Topics
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
Keywords
cutaneous afferents, ankle joint motion, directional tuning, peroneal nerve, cutaneous mechanoreceptors, kinesthesia, muscle afferents, preferred direction
MeSH terms
Adult, Ankle Joint, Humans, Models, Neurological, Movement, Neurons, Afferent, Skin

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review