The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Fluctuations in isometric muscle force can be described by one linear projection of low‐frequency components of motor unit discharge rates
Open accessAbstract
The aim of the study was to investigate the relation between linear transformations of motor unit discharge rates and muscle force. Intramuscular (wire electrodes) and high‐density surface EMG (13 × 5 electrode grid) were recorded from the abductor digiti minimi muscle of eight healthy men during 60 s contractions at 5%, 7.5% and 10% of the maximal force. Spike trains of a total of 222 motor units were identified from the EMG recordings with decomposition algorithms. Principal component analysis of the smoothed motor unit discharge rates indicated that one component (first common component, FCC) described 44.2 ± 7.5% of the total variability of the smoothed discharge rates when computed over the entire contraction interval and 64.3 ± 10.2% of the variability when computed over 5 s intervals. When the FCC was computed from four or more motor units per contraction, it correlated with the force produced by the muscle (62.7 ± 10.1%) by a greater degree (P < 0.001) than the smoothed discharge rates of individual motor units (41.4 ± 7.8%). The correlation between FCC and the force signal increased up to 71.8 ± 13.1% when the duration and the shape of the smoothing window for discharge rates were similar to the average motor unit twitch force. Moreover, the coefficients of variation (CoV) for the force and for the FCC signal were correlated in all subjects (R2 range = 0.14–0.56; P < 0.05) whereas the CoV for force was correlated to the interspike interval variability in only one subject (R2= 0.12; P < 0.05). Similar results were further obtained from measures on the tibialis anterior muscle of an additional eight subjects during contractions at forces up to 20% of the maximal force (e.g. FCC explained 59.8 ± 11.0% of variability of the smoothed discharge rates). In conclusion, one signal captures most of the underlying variability of the low‐frequency components of motor unit discharge rates and explains large part of the fluctuations in the motor output during isometric contractions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
EXCITABILITY AND INHIBITIBILITY OF MOTONEURONS OF DIFFERENT SIZES
Henneman, E., Somjen, G., & Carpenter, D. O. (1965) · Journal of Neurophysiology · doi:10.1152/jn.1965.28.3.599 · Cited by 1,123
Models of recruitment and rate coding organization in motor-unit pools.
Fuglevand, A. J., Winter, D. A., & Patla, A. E. (1993) · Journal of Neurophysiology · doi:10.1152/jn.1993.70.6.2470 · Cited by 988 · cited 4×
“For example, when using as a window the function proposed by Fuglevand et al. (1993) for describing the motor unit twitch force (with contraction time = 90 ms) instead of the Hann window, the association between the FCC and force signal increased to 71.8 ± 13.1% (average over all contraction…”
BackgroundMethodInfluentialPrincipal component analysis and exploratory factor analysis
Joliffe, I., & Morgan, B. (1992) · Statistical Methods in Medical Research · doi:10.1177/096228029200100105 · Cited by 570
Mechanisms that contribute to differences in motor performance between young and old adults
Enoka, R. M., Christou, E. A., Hunter, S. K., Kornatz, K. W., Semmler, J. G., Taylor, A. M., & Tracy, B. L. (2003) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(02)00084-6 · Cited by 562
Changes in firing rate of human motor units during linearly changing voluntary contractions
Milner‐Brown, H. S., Stein, R. B., & Yemm, R. (1973) · The Journal of Physiology · doi:10.1113/jphysiol.1973.sp010193 · Cited by 553
Control scheme governing concurrently active human motor units during voluntary contractions
de Luca, C. J., LeFever, R. S., McCue, M. P., & Xenakis, A. P. (1982) · The Journal of Physiology · doi:10.1113/jphysiol.1982.sp014294 · Cited by 510
Cumulative sum technique and its application to the analysis of peristimulus time histograms
Ellaway, P. H. (1978) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(78)90017-2 · Cited by 451
MORPHOLOGIC STUDIES OF MOTOR UNITS IN NORMAL HUMAN MUSCLES
Feinstein, B., Lindegård, B., Nyman, E., & Wohlfart, G. (1955) · Cells Tissues Organs · doi:10.1159/000140989 · Cited by 433
Person, R. S., & Kudina, L. P. (1972) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(72)90058-2 · Cited by 410
Matthews, P. B. (1996) · The Journal of Physiology · doi:10.1113/jphysiol.1996.sp021332 · Cited by 325
Estimating motor unit discharge patterns from high-density surface electromyogram.
Holobar, A., Farina, D., Gazzoni, M., Merletti, R., & Zazula, D. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.10.160 · Cited by 318
Self-citationEMGLAB: An interactive EMG decomposition program
McGill, K. C., Lateva, Z. C., & Marateb, H. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.05.015 · Cited by 317
EMG signal decomposition: how can it be accomplished and used?
Stashuk, D. (2001) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(00)00050-x · Cited by 268
Estimating the strength of common input to human motoneurons from the cross‐correlogram.
Nordstrom, M. A., Fuglevand, A. J., & Enoka, R. M. (1992) · The Journal of Physiology · doi:10.1113/jphysiol.1992.sp019244 · Cited by 259
Effects of aging on motor-unit control properties.
Erim, Z., Beg, M. F., Burke, D. T., & de Luca, C. J. (1999) · Journal of Neurophysiology · doi:10.1152/jn.1999.82.5.2081 · Cited by 256
Mannard, A., & Stein, R. B. (1973) · The Journal of Physiology · doi:10.1113/jphysiol.1973.sp010138 · Cited by 226
Ishizuka, N., Mannen, H., Hongo, T., & Sasaki, S. (1979) · Journal of Comparative Neurology · doi:10.1002/cne.901860206 · Cited by 189
Hand Dominance and Motor Unit Firing Behavior
Adam, A., Luca, C. J. D., & Erim, Z. (1998) · Journal of Neurophysiology · doi:10.1152/jn.1998.80.3.1373 · Cited by 184
Common Drive in Motor Units of a Synergistic Muscle Pair
De Luca, C. J., & Erim, Z. (2002) · Journal of Neurophysiology · doi:10.1152/jn.00793.2001 · Cited by 173
A technique for the detection, decomposition and analysis of the EMG signal
Mambrito, B., & De Luca, C. J. (1984) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(84)90031-2 · Cited by 167
Correlation-based decomposition of surface electromyograms at low contraction forces
Holobar, A., & Zazula, D. (2004) · Medical & Biological Engineering & Computing · doi:10.1007/bf02350989 · Cited by 167
Self-citationDavey, N. J., ELLAWAY, P. H., & Stein, R. B. (1986) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(86)90068-3 · Cited by 133
Lawrence, D. G., Porter, R. W., & Redman, S. (1985) · The Journal of Comparative Neurology · doi:10.1002/cne.902320407 · Cited by 131
Physiology of the motor neuron and the motor unit
Heckman, C. J., & Enoka, R. M. (2004) · Handbook of clinical neurophysiology · doi:10.1016/s1567-4231(04)04006-7 · Cited by 95
LEMON, R. N., & Mantel, G. W. H. (1989) · The Journal of Physiology · doi:10.1113/jphysiol.1989.sp017658 · Cited by 81
Adjustments Differ Among Low-Threshold Motor Units During Intermittent, Isometric Contractions
Farina, D., Holobar, A., Gazzoni, M., Zazula, D., Merletti, R., & Enoka, R. M. (2008) · Journal of Neurophysiology · doi:10.1152/jn.90968.2008 · Cited by 79
Self-citationFarina, D., Cescon, C., Negro, F., & Enoka, R. M. (2008) · Journal of Neurophysiology · doi:10.1152/jn.90365.2008 · Cited by 76
Self-citationSemmler, J. G., Nordstrom, M. A., & Wallace, C. J. (1997) · Brain Research · doi:10.1016/s0006-8993(97)00621-5 · Cited by 71
Ralston, H. J., Light, A. R., Ralston, D. D., & Perl, E. R. (1984) · Journal of Neurophysiology · doi:10.1152/jn.1984.51.4.777 · Cited by 70
Motor Unit Recruitment and Proprioceptive Feedback Decrease the Common Drive
Luca, C. J. D., González-Cueto, J. A., Bonato, P., & Adam, A. (2008) · Journal of Neurophysiology · doi:10.1152/jn.90245.2008 · Cited by 53
Mottram, C. J., Christou, E. A., Meyer, F. G., & Enoka, R. M. (2005) · Journal of Neurophysiology · doi:10.1152/jn.00390.2005 · Cited by 48
Semmler, J. G., & Nordstrom, M. A. (1999) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(99)00069-2 · Cited by 46
Cited by
Farina, D., Jiang, N., Rehbaum, H., Holobar, A., Graimann, B., Dietl, H., & Aszmann, O. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305111 · Cited by 992
Self-citationMulti-channel intramuscular and surface EMG decomposition by convolutive blind source separation
Negro, F., Muceli, S., Castronovo, A. M., Holobar, A., & Farina, D. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/026027 · Cited by 647
Self-citationThe extraction of neural strategies from the surface EMG: an update
Farina, D., Merletti, R., & Enoka, R. M. (2014) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00162.2014 · Cited by 589
Self-citationHeckman, C. J., & Enoka, R. M. (2012) · Comprehensive Physiology · doi:10.1002/cphy.c100087 · Cited by 414
Decoding the neural drive to muscles from the surface electromyogram
Farina, D., Holobar, A., Merletti, R., & Enoka, R. M. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.10.040 · Cited by 383
Self-citation
Metadata
- Authors
- Negro, F., Holobar, A., & Farina, D.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 2009-12-15
- Volume
- 587
- Issue
- 24
- Pages
- 5925-5938
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2130378672
- Cited by
- 336
- References
- 32
- FWCI
- 4.85
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.