Cited by 37Neuroscience and Neural EngineeringElectrochemical Analysis and ApplicationsElectrochemical sensors and biosensors

Measurement of the Direct-Current (Faradic) Resistance of the Electrode-Electrolyte Interface for Commonly Used Electrode Materials

Geddes, L. A., Roeder, R.·2001·Annals of Biomedical Engineering

Abstract

The direct-current (Faradic) resistance is important because it is the highest impedance that an electrode-electrolyte interface can attain. In this study, the Faradic resistance (Rf) of identical pairs of 0.5 cm2 electrodes of bare and chlorided silver, tin and chlorided tin, nickel-silver, copper, and carbon was measured in contact with 0.9% saline at room temperature. It was found that for positive and negative current flow, the data fit the expression Rf=Rf0 e(-alpha i) (with a high coefficient of determination), where Rf0 is the zero-current Faradic resistance and alpha is a constant that describes the manner in which Rf decreases with increasing current (i). It was found that chlorided silver exhibited the lowest Rf0; removing the chloride deposit increased Rf0 by more than sixfold. Likewise, chloriding tin reduced Rf0 by a factor of about 2. Electrolytically cleaning an electrode reduced Rf0. The highest value for Rf0 was for carbon. This paper concludes with a summary of the data for Rf0 scaled to 1 cm2 electrode area for the electrode materials measured in the present study and data from the published literature.

Integrity signals

Registry

Crossref · 10.1114/1.1349699

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cited by

Sorted by citations

Authors
Geddes, L. A., & Roeder, R.
Affiliations
Purdue University West Lafayette (US)
Venue
Annals of Biomedical Engineering
Published
2001-02
Volume
29
Issue
2
Pages
181-186
ISSN
0090-6964 (ISSN-L)
OpenAlex
W1977781268
Cited by
37
References
0
Citations by year
2025: 1 · 2022: 2 · 2021: 3 · 2020: 2 · 2018: 1 · 2016: 3 · 2015: 2 · 2014: 1 · 2013: 3 · 2012: 1
FWCI
0.37
Type
journal article
Language
en
Open access
closed
Locations
  • Annals of Biomedical Engineering (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
Keywords
Faradaic resistance, electrode-electrolyte interface, electrode impedance, saline, copper electrode, carbon electrodes, electrolytic cleaning, current-dependent resistance, electrode materials
MeSH terms
Biomedical Engineering, Carbon, Copper, Electrodes, Electrolytes, Nickel, Silver, Tin, Electric Impedance

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review