Criteria for the Selection of Materials for Implanted Electrodes

Geddes, L. A., Roeder, R.·2003·Annals of Biomedical Engineering

Abstract

There are four criteria that must be considered when choosing material for an implanted electrode: (1) tissue response, (2) allergic response, (3) electrode-tissue impedance, and (4) radiographic visibility. This paper discusses these four criteria and identifies the materials that are the best candidates for such electrodes. For electrodes that make ohmic contact with tissues: gold, platinum, platinum-iridium, tungsten, and tantalum are good candidates. The preferred insulating materials are polyimide and glass. The characteristics of stimulator output circuits and the importance of the bidirectional waveform in relation to electrode decomposition are discussed. The paper concludes with an analysis, the design criteria, and the special properties and materials for capacitive recording and stimulating electrodes.

Integrity signals

Registry

Crossref · 10.1114/1.1581292

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Good candidates for ohmic electrode-tissue contacts are gold, platinum, platinum-iridium, tungsten, and tantalum.

    “Good candidates for ohmic electrode-tissue contacts are gold, platinum (Pt), platinum-iridium, tungsten, and tantalum”
  • A foreign body response over contacts within excitable tissue will increase separation between the electrode and target tissue, leading to a raised stimulation threshold proportional to scar tissue thickness and a drop in recording sensitivities.

    “The electrical interface must be stable as a foreign body response over the contacts within excitable tissue will increase the separation between the electrode and the target tissue, leading to a raised stimulation threshold that is proportional to the scar tissue thickness and a drop in recording sensitivities (Geddes and Roeder 2003).”

    From Peripheral nerve bionic interface: a review of electrodes (2019) · cites this paper as Geddes and Roeder 2003

  • Encapsulation materials for implants need to be both biocompatible and resistant to bio-dissolution.

    “Encapsulation materials which are conventionally electrical insulators need to be both biocompatible and resistant to bio-dissolution (Geddes and Roeder 2003; Joung 2013).”

    From Peripheral nerve bionic interface: a review of electrodes (2019) · cites this paper as Geddes and Roeder 2003

  • Cardiac pacemakers' threshold current is established during surgery, then doubled to account for the expected bioresponse to the implant.

    “Cardiac pacemakers' threshold current is established during surgery, then doubled to account for the expected bioresponse to the implant (Geddes and Roeder 2003).”

    From Peripheral nerve bionic interface: a review of electrodes (2019) · cites this paper as Geddes and Roeder 2003

  • Stimulating without a DC bias reduces electro-decomposition of electrical contacts, and bi-phasic pulses with a zero-net-charge have a similar response.

    “The longevity of the implant can be further improved through the operation of the electrodes, stimulating without a DC bias will reduce electro-decomposition of the electrical contacts, whilst bi-phasic pulses with a zero-net-charge have a similar response (Geddes and Roeder 2003).”

    From Peripheral nerve bionic interface: a review of electrodes (2019) · cites this paper as Geddes and Roeder 2003

Cites

Flagged first, then by citations

1 of the 31 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Geddes, L. A., & Roeder, R.
Affiliations
Purdue University West Lafayette (US)
Venue
Annals of Biomedical Engineering
Published
2003-07
Volume
31
Issue
7
Pages
879-890
ISSN
0090-6964 (ISSN-L)
OpenAlex
W1978696561
Cited by
240
References
31
Citations by year
2026: 5 · 2025: 5 · 2024: 12 · 2023: 8 · 2022: 13 · 2021: 18 · 2020: 19 · 2019: 21 · 2018: 20 · 2017: 15 · 2016: 19 · 2015: 11 · 2014: 18 · 2013: 7 · 2012: 8
FWCI
0.92
Type
journal article
Language
en
Open access
closed
Locations
  • Annals of Biomedical Engineering (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
  • Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
Keywords
implanted electrodes, electrode materials, tissue reaction, allergic reactions, gold, platinum, tungsten, tantalum, polyimide, glass insulators
MeSH terms
Biocompatible Materials, Decision Support Techniques, Electrodes, Implanted, Electrophysiology, Equipment Design, Hypersensitivity, Materials Testing, Microelectrodes, Technology Assessment, Biomedical, Equipment Failure Analysis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review