Microstructural Mechanics of Collagen Gels in Confined Compression: Poroelasticity, Viscoelasticity, and Collapse
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background: Collagen gels are important as platforms for in vitro study of cell behavior and as prototypical bioartificial tissues, but their mechanical behavior, particularly on the microscopic scale, is still poorly understood. Method of Approach: Collagen gels were studied in step (10% strain in 0.05 s) and ramp (0.1%/s strain rate for 100 s) confined compression. Real-time birefringence mapping gave the local collagen concentration and orientation along with piston stress. Variations in the retardation allowed material-point tracking and qualitative determination of the strain distribution. Results: Ramp tests showed classical poroelastic behavior: compression near the piston and relaxation to a uniform state. Step tests, however, showed an irreversibly collapsed region near the piston. Conclusions: Our results suggest that interstitial flow and fibril bending at crosslinks are the dominant mechanical processes during compression, and that fibril bending is reversible before collapse.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Roeder, B. A., Kokini, K., Sturgis, J. E., Robinson, J. P., & Voytik-Harbin, S. L. (2002) · Journal of Biomechanical Engineering · doi:10.1115/1.1449904 · Cited by 620
Cited by
Functional and Biomimetic Materials for Engineering of the Three-Dimensional Cell Microenvironment
Huang, G., Li, F., Zhao, X., Ma, Y., Li, Y., Lin, M., Jin, G., Lu, T. J., Genin, G. M., & Xu, F. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00094 · Cited by 825
Antoine, E. E., Vlachos, P. P., & Rylander, M. N. (2014) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2014.0086 · Cited by 611
“Chandran and Barocas provide an excellent review of experimental methodologies for each deformation mode, discussing underlying physics and highlighting advantages and limitations of each.(65) In all deformation modes, it is critical to maintain sample integrity by humidification or immersion in a buffer solution duri…”
Mechanobiology in the Third Dimension
Pedersen, J. A., & Swartz, M. A. (2005) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-8159-4 · Cited by 389
Strain-Induced Alignment in Collagen Gels
Vader, D., Kabla, A., Weitz, D., & Mahadevan, L. (2009) · PLoS ONE · doi:10.1371/journal.pone.0005902 · Cited by 389
Niu, L.-N., Jee, S. E., Jiao, K., Tonggu, L., Li, M., Wang, L., Yang, Y.-D., Bian, J.-H., Breschi, L., Jang, S. S., et al. (2017) · Nature Materials · doi:10.1038/nmat4789 · Cited by 337
Metadata
- Authors
- Chandran, P. L., & Barocas, V. H.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 2004-04-01
- Volume
- 126
- Issue
- 2
- Pages
- 152-166
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2075173045
- Cited by
- 153
- References
- 1
- FWCI
- 1.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.