The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Validation of a New Model-Based Tracking Technique for Measuring Three-Dimensional, In Vivo Glenohumeral Joint Kinematics
Open accessAbstract
Shoulder motion is complex and significant research efforts have focused on measuring glenohumeral joint motion. Unfortunately, conventional motion measurement techniques are unable to measure glenohumeral joint kinematics during dynamic shoulder motion to clinically significant levels of accuracy. The purpose of this study was to validate the accuracy of a new model-based tracking technique for measuring three-dimensional, in vivo glenohumeral joint kinematics. We have developed a model-based tracking technique for accurately measuring in vivo joint motion from biplane radiographic images that tracks the position of bones based on their three-dimensional shape and texture. To validate this technique, we implanted tantalum beads into the humerus and scapula of both shoulders from three cadaver specimens and then recorded biplane radiographic images of the shoulder while manually moving each specimen’s arm. The position of the humerus and scapula were measured using the model-based tracking system and with a previously validated dynamic radiostereometric analysis (RSA) technique. Accuracy was reported in terms of measurement bias, measurement precision, and overall dynamic accuracy by comparing the model-based tracking results to the dynamic RSA results. The model-based tracking technique produced results that were in excellent agreement with the RSA technique. Measurement bias ranged from −0.126to0.199mm for the scapula and ranged from −0.022to0.079mm for the humerus. Dynamic measurement precision was better than 0.130mm for the scapula and 0.095mm for the humerus. Overall dynamic accuracy indicated that rms errors in any one direction were less than 0.385mm for the scapula and less than 0.374mm for the humerus. These errors correspond to rotational inaccuracies of approximately 0.25deg for the scapula and 0.47deg for the humerus. This new model-based tracking approach represents a non-invasive technique for accurately measuring dynamic glenohumeral joint motion under in vivo conditions. The model-based technique achieves accuracy levels that far surpass all previously reported non-invasive techniques for measuring in vivo glenohumeral joint motion. This technique is supported by a rigorous validation study that provides a realistic simulation of in vivo conditions and we fully expect to achieve these levels of accuracy with in vivo human testing. Future research will use this technique to analyze shoulder motion under a variety of testing conditions and to investigate the effects of conservative and surgical treatment of rotator cuff tears on dynamic joint stability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wu, G., van der Helm, F. C. T., (DirkJan) Veeger, H. E. J., Makhsous, M., Van Roy, P., Anglin, C., Nagels, J., Karduna, A. R., McQuade, K., Wang, X., et al. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.05.042 · Cited by 4,558
Kinetics of Baseball Pitching with Implications About Injury Mechanisms
Fleisig, G. S., Andrews, J. R., Dillman, C. J., & Escamilla, R. F. (1995) · The American Journal of Sports Medicine · doi:10.1177/036354659502300218 · Cited by 1,513
NEER, C. S. (1983) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198303000-00010 · Cited by 1,335
Normal and abnormal motion of the shoulder
Poppen, N., & Walker, P. (1976) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197658020-00006 · Cited by 885
Abnormal Rotational Knee Motion during Running after Anterior Cruciate Ligament Reconstruction
Tashman, S., Collon, D., Anderson, K., Kolowich, P., & Anderst, W. (2004) · The American Journal of Sports Medicine · doi:10.1177/0363546503261709 · Cited by 722
Self-citationDirect 3-dimensional measurement of scapular kinematics during dynamic movements in vivo
McClure, P. W., Michener, L. A., Sennett, B. J., & Karduna, A. R. (2001) · Journal of Shoulder and Elbow Surgery · doi:10.1067/mse.2001.112954 · Cited by 721
Kinematic and kinetic comparison of baseball pitching among various levels of development
Fleisig, G. S., Barrentine, S. W., Zheng, N., Escamilla, R. F., & Andrews, J. R. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00127-x · Cited by 645
Dynamic Measurements of Three-Dimensional Scapular Kinematics: A Validation Study
Karduna, A. R., McClure, P. W., Michener, L. A., & Sennett, B. (2001) · Journal of Biomechanical Engineering · doi:10.1115/1.1351892 · Cited by 622
Biomechanics of Pitching With Emphasis Upon Shoulder Kinematics
Dillman, C. J., Fleisig, G. S., & Andrews, J. R. (1993) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.1993.18.2.402 · Cited by 602
Tashman, S., & Anderst, W. (2003) · Journal of Biomechanical Engineering · doi:10.1115/1.1559896 · Cited by 305
Self-citation
Cited by
Kinematic coupling of the glenohumeral and scapulothoracic joints generates humeral axial rotation
Aliaj, K., Lawrence, R. L., Bo Foreman, K., Chalmers, P. N., & Henninger, H. B. (2022) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2022.111059 · Cited by 15
Metadata
- Authors
- Bey, M. J., Zauel, R., Brock, S. K., & Tashman, S.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 2006-01-31
- Volume
- 128
- Issue
- 4
- Pages
- 604-609
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2115553482
- Cited by
- 300
- References
- 20
- FWCI
- 7.48
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validation of a New Model-Based Tracking Technique for Measuring Three-Dimensional, In Vivo Glenohumeral Joint Kinematics. https://app.cochat.ai/papers/10.1115/1.2206199
- The paper
- Bey, M. J., Zauel, R., Brock, S. K., & Tashman, S. (2006). Validation of a New Model-Based Tracking Technique for Measuring Three-Dimensional, In Vivo Glenohumeral Joint Kinematics. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.2206199
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.