Experimental and Numerical Study of a Stacked Microchannel Heat Sink for Liquid Cooling of Microelectronic Devices
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
One of the promising liquid cooling techniques for microelectronics is attaching a microchannel heat sink to, or directly fabricating microchannels on, the inactive side of the chip. A stacked microchannel heat sink integrates many layers of microchannels and manifold layers into one stack. Compared with single-layered microchannels, stacked microchannels provide larger flow passages, so that for a fixed heat load the required pressure drop is significantly reduced. Better temperature uniformity can be achieved by arranging counterflow in adjacent microchannel layers. The dedicated manifolds help to distribute coolant uniformly to microchannels. In the present work, a stacked microchannel heat sink is fabricated using silicon micromachining techniques. Thermal performance of the stacked microchannel heat sink is characterized through experimental measurements and numerical simulations. Effects of coolant flow direction, flow rate allocation among layers, and nonuniform heating are studied. Wall temperature profiles are measured using an array of nine platinum thin-film resistive temperature detectors deposited simultaneously with thin-film platinum heaters on the backside of the stacked structure. Excellent overall cooling performance (0.09°C∕Wcm2) for the stacked microchannel heat sink has been shown in the experiments. It has also been identified that over the tested flow rate range, counterflow arrangement provides better temperature uniformity, while parallel flow has the best performance in reducing the peak temperature. Conjugate heat transfer effects for stacked microchannels for different flow conditions are investigated through numerical simulations. Based on the results, some general design guidelines for stacked microchannel heat sinks are provided.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Qu, W., & Mudawar, I. (2002) · International Journal of Heat and Mass Transfer · doi:10.1016/s0017-9310(01)00337-4 · Cited by 1,033
Flow characteristics of water in microtubes
Mohiuddin Mala, G., & Li, D. (1999) · International Journal of Heat and Fluid Flow · doi:10.1016/s0142-727x(98)10043-7 · Cited by 706
Peiyi, W., & Little, W. A. (1983) · Cryogenics · doi:10.1016/0011-2275(83)90150-9 · Cited by 520
Analysis of two-layered micro-channel heat sink concept in electronic cooling
Vafai, K., & Zhu, L. (1999) · International Journal of Heat and Mass Transfer · doi:10.1016/s0017-9310(98)00017-9 · Cited by 485
High flux boiling in low flow rate, low pressure drop mini-channel and micro-channel heat sinks
Bowers, M. B., & Mudawar, I. (1994) · International Journal of Heat and Mass Transfer · doi:10.1016/0017-9310(94)90103-1 · Cited by 483
Three-dimensional conjugate heat transfer in the microchannel heat sink for electronic packaging
Fedorov, A. G., & Viskanta, R. (2000) · International Journal of Heat and Mass Transfer · doi:10.1016/s0017-9310(99)00151-9 · Cited by 446
FRICTIONAL FLOW CHARACTERISTICS OF WATER FLOWING THROUGH RECTANGULAR MICROCHANNELS
Peng, X. F., Peterson, G. P., & Wang, B. X. (1994) · Experimental Heat Transfer · doi:10.1080/08916159408946484 · Cited by 381
Developing convective heat transfer in deep rectangular microchannels
Harms, T. M., Kazmierczak, M. J., & Gerner, F. M. (1999) · International Journal of Heat and Fluid Flow · doi:10.1016/s0142-727x(98)10055-3 · Cited by 369
Laminar fluid behavior in microchannels using micropolar fluid theory
Papautsky, I., Brazzle, J., Ameel, T., & Frazier, A. B. (1999) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(98)00261-1 · Cited by 301
An experimental investigation of microchannel flow with internal pressure measurements
Kohl, M. J., Abdel-Khalik, S. I., Jeter, S. M., & Sadowski, D. L. (2005) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2004.10.030 · Cited by 254
Cited by
He, Z., Yan, Y., & Zhang, Z. (2021) · Energy · doi:10.1016/j.energy.2020.119223 · Cited by 869
Li, H., Ding, X., Meng, F., Jing, D., & Xiong, M. (2019) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2019.118638 · Cited by 256
Heat transfer augmentation in microchannel heat sink using secondary flows: A review
Sadique, H., Murtaza, Q., & Samsher (2022) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2022.123063 · Cited by 196
Kandlikar, S. G., & Hayner, C. N. (2009) · Heat Transfer Engineering · doi:10.1080/01457630902837343 · Cited by 124
Metadata
- Authors
- Wei, X., Joshi, Y., & Patterson, M. K.
- Venue
- Journal of Heat Transfer
- Publisher
- ASME International
- Published
- 2007-02-23
- Volume
- 129
- Issue
- 10
- Pages
- 1432-1444
- ISSN
- 0022-1481 (ISSN-L)
- 1528-8943
- OpenAlex
- W2023372719
- Cited by
- 248
- References
- 22
- FWCI
- 13.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.