The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Molding of Deep Polydimethylsiloxane Microstructures for Microfluidics and Biological Applications
Abstract
Here we demonstrate the microfabrication of deep (>25 μm) polymeric microstructures created by replica-molding polydimethylsiloxane (PDMS) from microfabricated Si substrates. The use of PDMS structures in microfluidics and biological applications is discussed. We investigated the feasibility of two methods for the microfabrication of the Si molds: deep plasma etch of silicon-on-insulator (SOI) wafers and photolithographic patterning of a spin-coated photoplastic layer. Although the SOI wafers can be patterned at higher resolution, we found that the inexpensive photoplastic yields similar replication fidelity. The latter is mostly limited by the mechanical stability of the replicated PDMS structures. As an example, we demonstrate the selective delivery of different cell suspensions to specific locations of a tissue culture substrate resulting in micropatterns of attached cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chaudhury, M. K., & Whitesides, G. M. (1991) · Langmuir · doi:10.1021/la00053a033 · Cited by 658
Cited by
Fabrication of microfluidic systems in poly(dimethylsiloxane)
McDonald, J. C., Duffy, D. C., Anderson, J. R., Chiu, D. T., Wu, H., Schueller, O. J. A., & Whitesides, G. M. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<27::aid-elps27>3.0.co;2-c · Cited by 3,329
Bhatia, S. N., & Ingber, D. E. (2014) · Nature Biotechnology · doi:10.1038/nbt.2989 · Cited by 3,305
Poly(dimethylsiloxane) as a Material for Fabricating Microfluidic Devices
McDonald, J. C., & Whitesides, G. M. (2002) · Accounts of Chemical Research · doi:10.1021/ar010110q · Cited by 2,454
Patterning proteins and cells using soft lithography
Kane, R. (1999) · Biomaterials · doi:10.1016/s0142-9612(99)00165-9 · Cited by 1,490
Efimenko, K., Wallace, W. E., & Genzer, J. (2002) · Journal of Colloid and Interface Science · doi:10.1006/jcis.2002.8594 · Cited by 757
Microengineering of Cellular Interactions
Folch, A., & Toner, M. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.227 · Cited by 602
Self-citationChiu, D. T., Jeon, N. L., Huang, S., Kane, R. S., Wargo, C. J., Choi, I. S., Ingber, D. E., & Whitesides, G. M. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.040562297 · Cited by 526
Cell–Material Interactions Revealed Via Material Techniques of Surface Patterning
Yao, X., Peng, R., & Ding, J. (2013) · Advanced Materials · doi:10.1002/adma.201301762 · Cited by 501
Integration of Cell Culture and Microfabrication Technology
Park, T. H., & Shuler, M. L. (2003) · Biotechnology Progress · doi:10.1021/bp020143k · Cited by 473
An Integrated Fluorescence Detection System in Poly(dimethylsiloxane) for Microfluidic Applications
Chabinyc, M. L., Chiu, D. T., McDonald, J. C., Stroock, A. D., Christian, J. F., Karger, A. M., & Whitesides, G. M. (2001) · Analytical Chemistry · doi:10.1021/ac010423z · Cited by 419
Fabrication of PLGA scaffolds using soft lithography and microsyringe deposition
Vozzi, G., Flaim, C., Ahluwalia, A., & Bhatia, S. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00052-8 · Cited by 373
Methods for Fabrication of Nanoscale Topography for Tissue Engineering Scaffolds
Norman, J. J., & Desai, T. A. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-9005-4 · Cited by 364
Xurography: rapid prototyping of microstructures using a cutting plotter
Bartholomeusz, D. A., Boutte, R. W., & Andrade, J. D. (2005) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2005.859087 · Cited by 360
Microfabricated elastomeric stencils for micropatterning cell cultures
Folch, A., Jo, B.-H., Hurtado, O., Beebe, D. J., & Toner, M. (2000) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200011)52:2<346::aid-jbm14>3.0.co;2-h · Cited by 354
Self-citationCell and protein compatibility of parylene-C surfaces
Chang, T. Y., Yadav, V. G., De Leo, S., Mohedas, A., Rajalingam, B., Chen, C.-L., Selvarasah, S., Dokmeci, M. R., & Khademhosseini, A. (2007) · Langmuir · doi:10.1021/la7017049 · Cited by 320
Thermally responsive polymer-grafted surfaces facilitate patterned cell seeding and co-culture
Yamato, M., Konno, C., Utsumi, M., Kikuchi, A., & Okano, T. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00138-7 · Cited by 313
Microfabrication and microfluidics for tissue engineering: state of the art and future opportunities
Andersson, H., & Berg, A. V. D. (2004) · Lab on a Chip · doi:10.1039/b314469k · Cited by 307
Micro- and nanoscale structures for tissue engineering constructs
Desai, T. A. (2000) · Medical Engineering & Physics · doi:10.1016/s1350-4533(00)00087-4 · Cited by 302
Layer-by-layer microfluidics for biomimetic three-dimensional structures
Tan, W., & Desai, T. A. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.08.021 · Cited by 193
Chien, H.-W., & Tsai, W.-B. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.06.033 · Cited by 70
Metadata
- Authors
- Folch, A., Ayon, A., Hurtado, O., Schmidt, M. A., & Toner, M.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 1999-02-01
- Volume
- 121
- Issue
- 1
- Pages
- 28-34
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2058238342
- Cited by
- 174
- References
- 1
- FWCI
- 10.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.