Cell and protein compatibility of parylene-C surfaces
Abstract
Parylene-C, which is traditionally used to coat implantable devices, has emerged as a promising material to generate miniaturized devices due to its unique mechanical properties and inertness. In this paper we compared the surface properties and cell and protein compatibility of parylene-C relative to other commonly used BioMEMS materials. We evaluated the surface hydrophobicity and roughness of parylene-C and compared these results to those of tissue culture-treated polystyrene, poly(dimethylsiloxane) (PDMS), and glass. We also treated parylene-C and PDMS with air plasma, and coated the surfaces with fibronectin to demonstrate that biochemical treatments modify the surface properties of parylene-C. Although plasma treatment caused both parylene-C and PDMS to become hydrophilic, only parylene-C substrates retained their hydrophilic properties over time. Furthermore, parylene-C substrates display a higher degree of nanoscale surface roughness (>20 nm) than the other substrates. We also examined the level of BSA and IgG protein adsorption on various surfaces and found that surface plasma treatment decreased the degree of protein adsorption on both PDMS and parylene-C substrates. After testing the degree of cell adhesion and spreading of two mammalian cell types, NIH-3T3 fibroblasts and AML-12 hepatocytes, we found that the adhesion of both cell types to surface-treated parylene-C variants were comparable to standard tissue culture substrates, such as polystyrene. Overall, these results indicate that parylene-C, along with its surface-treated variants, could potentially be a useful material for fabricating cell-based microdevices.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Parylene C has a well-established history of biocompatibility and biostability.
“Parylene C has recently arisen as a good material option for peripheral nerve devices (de la Oliva et al., 2018), and has a well-established history of biocompatibility and biostability (Chang et al., 2007; Winslow et al., 2010; Hassler et al., 2011).”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Chang et al., 2007
Cites
Langer, R., & Vacanti, J. P. (1993) · Science · doi:10.1126/science.8493529 · Cited by 9,893 · see citing works
Soft Lithography in Biology and Biochemistry
Whitesides, G. M., Ostuni, E., Takayama, S., Jiang, X., & Ingber, D. E. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.335 · Cited by 2,603 · see citing works
Microfluidic Large-Scale Integration
Thorsen, T., Maerkl, S. J., & Quake, S. R. (2002) · Science · doi:10.1126/science.1076996 · Cited by 2,223 · see citing works
The Basic Science of Gene Therapy
Mulligan, R. C. (1993) · Science · doi:10.1126/science.8493530 · Cited by 1,734 · see citing works
Microfluidic devices fabricated in Poly(dimethylsiloxane) for biological studies
Sia, S. K., & Whitesides, G. M. (2003) · Electrophoresis · doi:10.1002/elps.200305584 · Cited by 1,722 · see citing works
Microscale technologies for tissue engineering and biology
Khademhosseini, A., Langer, R., Borenstein, J. T., & Vacanti, J. P. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0507681102 · Cited by 1,553 · see citing works
Self-citationSelf-Assembly of Highly Phosphorylated Silaffins and Their Function in Biosilica Morphogenesis
Kröger, N., Lorenz, S., Brunner, E., & Sumper, M. (2002) · Science · doi:10.1126/science.1076221 · Cited by 792 · see citing works
Langer, R. (2001) · Science · doi:10.1126/science.1063273 · Cited by 580 · see citing works
Molecular imprinting within hydrogels
Byrne, M. E., Park, K., & Peppas, N. A. (2002) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(01)00246-0 · Cited by 569 · see citing works
BioMEMS: state-of-the-art in detection, opportunities and prospects
Bashir, R. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2004.03.002 · Cited by 463 · see citing works
Miller, D. C., Thapa, A., Haberstroh, K. M., & Webster, T. J. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00471-x · Cited by 420 · see citing works
Compatibility of Mammalian Cells on Surfaces of Poly(dimethylsiloxane)
Lee, J. N., Jiang, X., Ryan, D., & Whitesides, G. M. (2004) · Langmuir · doi:10.1021/la048562+ · Cited by 379 · see citing works
Endothelialized Microvasculature Based on a Biodegradable Elastomer
Fidkowski, C. W., Mofrad, M. R. K., Borenstein, J. T., Vacanti, J. P., Langer, R., & Wang, Y. (2005) · Tissue Engineering · doi:10.1089/ten.2005.11.302 · Cited by 343 · see citing works
Silicon Micromachining to Tissue Engineer Branched Vascular Channels for Liver Fabrication
Kaihara, S., Borenstein, J. T., Koka, R., Lalan, S., Ochoa, E. R., Ravens, M., Pien, H. H., Cunningham, B. T., & Vacanti, J. P. (2000) · Tissue Engineering · doi:10.1089/107632700320739 · Cited by 324 · see citing works
The surface energy of various biomaterials coated with adhesion molecules used in cell culture
Harnett, E. M., Alderman, J., & Wood, T. (2006) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2006.11.021 · Cited by 296 · see citing works
Protein adsorption to polymer particles: Role of surface properties
Absolom, D. R., Zingg, W., & Neumann, A. W. (1987) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820210202 · Cited by 261 · see citing works
MacDonald, D. E., Rapuano, B. E., Deo, N., et al. (2003) · Biomaterials · doi:10.1016/j.biomaterials.2003.10.029 · Cited by 248 · see citing works
Long-term implants of Parylene-C coated microelectrodes
Schmidt, E., Mcintosh, J. S., & Bak, M. (2006) · Medical and Biological Engineering and Computing · doi:10.1007/bf02441836 · Cited by 216 · see citing works
A Micromachined Chip-Based Electrospray Source for Mass Spectrometry
Licklider, L., Wang, X.-Q., Desai, A., et al. (1999) · Analytical Chemistry · doi:10.1021/ac990967p · Cited by 196 · see citing works
Molding of Deep Polydimethylsiloxane Microstructures for Microfluidics and Biological Applications
Folch, A., Ayón, A. A., Hurtado, O., et al. (1999) · Journal of Biomechanical Engineering · doi:10.1115/1.2798038 · Cited by 175 · see citing works
A Soft Lithographic Approach To Fabricate Patterned Microfluidic Channels
Khademhosseini, A., Suh, K. Y., Jon, S., Eng, G. M., Yeh, J., Chen, G.-J., & Langer, R. (2004) · Analytical Chemistry · doi:10.1021/ac035415s · Cited by 166 · see citing works
Self-citationA wettability gradient as a tool to study protein adsorption and cell adhesion on polymer surfaces
Lee, J. H., & Lee, H. B. (1993) · Journal of Biomaterials Science Polymer Edition · doi:10.1163/156856293x00131 · Cited by 161 · see citing works
Xie, J., Miao, Y., Shih, J., et al. (2005) · Analytical Chemistry · doi:10.1021/ac0510888 · Cited by 158 · see citing works
Toworfe, G. K., Composto, R. J., Adams, C. S., et al. (2004) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30164 · Cited by 150 · see citing works
Surface micromachined electrostatically actuated micro peristaltic pump
Xie, J., Shih, J., Lin, Q., et al. (2004) · Lab on a Chip · doi:10.1039/b403906h · Cited by 148 · see citing works
Weisenberg, B. A., & Mooradian, D. L. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10076 · Cited by 133 · see citing works
Generation of static and dynamic patterned co-cultures using microfabricated parylene-C stencils
Wright, D., Rajalingam, B., Selvarasah, S., Dokmeci, M. R., & Khademhosseini, A. (2007) · Lab on a Chip · doi:10.1039/b706081e · Cited by 132 · see citing works
Self-citationReusable, reversibly sealable parylene membranes for cell and protein patterning
Wright, D., Rajalingam, B., Karp, J. M., et al. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31281 · Cited by 123 · see citing works
Self-citationLoeb, G. E., Walker, A. E., Uematsu, S., & Konigsmark, B. W. (1977) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820110206 · Cited by 95 · see citing works
Differential surface binding of albumin, immunoglobulin G and fibrinogen
Warkentin, P. H., Wälivaara, B., Lundström, I., et al. (1994) · Biomaterials · doi:10.1016/0142-9612(94)90033-7 · Cited by 61 · see citing works
Chen, P., Shih, C.-Y., & Tai, Y. (2006) · Lab on a Chip · doi:10.1039/b600224b · Cited by 50 · see citing works
Fibroblast cell attachment and growth on nanoengineered sculptured thin films
Demirel, M. C., So, E., Ritty, T. M., et al. (2006) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.30656 · Cited by 49 · see citing works
Biocomplatible parylene neurocages
Tooker, A., Meng, E. F., Erickson, J., et al. (2005) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2005.1549727 · Cited by 48 · see citing works
13th International Conference on Solid-State Sensors, Actuators and Microsystems
(2004) · IEEE Electron Device Letters · doi:10.1109/led.2004.838896 · Cited by 28 · see citing works
Silicon couplers for microfluidic applications
Meng, E. F., Wu, S., & Tai, Y. (2001) · Fresenius Journal of Analytical Chemistry · doi:10.1007/s002160101002 · Cited by 26 · see citing works
Ice Ages, the California Current, and Devils Hole
Lea, D. W. (2001) · Science · doi:10.1126/science.1061078 · Cited by 21 · see citing works
Bianchi, F., Vassalle, C., Simonetti, M., et al. (2005) · Journal of Biomaterials Science Polymer Edition · doi:10.1163/156856206774879117 · Cited by 21 · see citing works
Growth of cultured calf aortic smooth muscle cells on cardiovascular prosthetic materials
Eskin, S. G., Armeniades, C. D., Lie, J. T., et al. (1976) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820100111 · Cited by 20 · see citing works
Selvarasah, S., Chao, S.-H., Chen, C.-L., et al. (2007) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/sensor.2007.4300185 · Cited by 12 · see citing works
Self-citationGlow discharge polymers as coatings for implanted devices.
Hahn, A. W., Hk, Y., James, W. J., et al. (1981) · PubMed · Cited by 9 · see citing works
Developing A Robust Method for Live Neural Network Studies
Tooker, A., Meng, E. F., Erickson, J. J., et al. (2005) · Cited by 4 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
A Review of Organic and Inorganic Biomaterials for Neural Interfaces
Fattahi, P., Yang, G., Kim, G., & Abidian, M. R. (2014) · Advanced Materials · doi:10.1002/adma.201304496 · Cited by 580 · see citing works
Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics
Carnicer-Lombarte, A., Chen, S.-T., Malliaras, G. G., & Barone, D. G. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.622524 · Cited by 454 · see citing works
“Parylene C has recently arisen as a good material option for peripheral nerve devices (de la Oliva et al., 2018), and has a wellestablished history of biocompatibility and biostability (Chang et al., 2007; Winslow et al., 2010; Hassler et al., 2011).”
BackgroundTemperature- and pH-sensitive wearable materials for monitoring foot ulcers
Salvo, P., Calisi, N., Melai, B., Dini, V., Paoletti, C., Lomonaco, T., Pucci, A., Di Francesco, F., Piaggesi, A., & Romanelli, M. (2017) · International Journal of Nanomedicine · doi:10.2147/ijn.s121726 · Cited by 76 · see citing works
Rivera, K. R., Yokus, M. A., Erb, P. D., Pozdin, V. A., & Daniele, M. (2019) · The Analyst · doi:10.1039/c8an02201a · Cited by 57 · see citing works
- Authors
- Chang, T. Y., Yadav, V. G., De Leo, S., Mohedas, A., Rajalingam, B., Chen, C.-L., Selvarasah, S., Dokmeci, M. R., & Khademhosseini, A.
- Affiliations
- Louisiana State University (US)
- Department of Biology, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, Department of Chemical Engineering, University of Waterloo, Waterloo, Canada N2L 3G1, Department of Biological Engineering, Louisiana State University, Baton Rouge, Louisiana 70808, Department of Biomedical Engineering, Texas A&M University, College Station, Texas 77843, Center for Biomedical Engineering, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts 02139,...
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-10-04
- Volume
- 23
- Issue
- 23
- Pages
- 11718-11725
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W2046039187
- Cited by
- 320
- References
- 41
- Citations by year
- 2026: 6 · 2025: 14 · 2024: 12 · 2023: 10 · 2022: 7 · 2021: 13 · 2020: 17 · 2019: 18 · 2018: 15 · 2017: 23 · 2016: 33 · 2015: 21 · 2014: 20 · 2013: 25 · 2012: 22
- FWCI
- 7.16
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Langmuir (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Materials Science › Surfaces, Coatings and Films › Polymer Surface Interaction Studies
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Cellular Mechanics and Interactions
- Keywords
- Parylene C, BioMEMS, surface hydrophobicity, surface roughness, air plasma treatment, fibronectin coating, protein adsorption, BSA, IgG, cell adhesion, NIH3T3 cells, polydimethylsiloxane
- MeSH terms
- Animals, Cell Adhesion, Cell Line, Dimethylpolysiloxanes, Fibroblasts, Glass, Immunoglobulin G, Polymers, Polystyrenes, Proteins, Serum Albumin, Bovine, Silicones, Surface Properties, Xylenes, 3T3 Cells, Fluorescein-5-isothiocyanate, Microscopy, Atomic Force, Coated Materials, Biocompatible, Hepatocytes, Tissue Engineering, Mice, Hydrophobic and Hydrophilic Interactions
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review