CoChat

Dynamic Contact of the Human Fingerpad Against a Flat Surface

Pawluk, D. T. V., Howe, R. D. · 1999 · Journal of Biomechanical Engineering
Cited by 135

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

This paper investigates the dynamic, distributed pressure response of the human fingerpad in vivo when it first makes contact with an object. A flat probe was indented against the fingerpad at a 20 to 40 degree angle. Ramp-and-hold and sinusoidal displacement trajectories were applied to the fingerpad within a force range of 0–2 N. The dynamic spatial distribution of the pressure response was measured using a tactile array sensor. Both the local pressure variation and the total force exhibited nonlinear stiffness (exponential with displacement) and significant temporal relaxation. The shape of the contact pressure distribution could plausibly be described by an inverted paraboloid. A model based on the contact of a rigid plane (the object) and a linear viscoelastic sphere (the fingerpad), modified to include a nonlinear modulus of elasticity, can account for the principal features of the distributed pressure response.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1115/1.2800860

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Pawluk, D. T. V., & Howe, R. D.
Venue
Journal of Biomechanical Engineering
Published
1999-12-01
Volume
121
Issue
6
Pages
605-611
ISSN
  • 0148-0731 (ISSN-L)
  • 1528-8951
OpenAlex
W2046558508
Cited by
135
References
2
FWCI
0.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.