Finite Element Implementation of Anisotropic Quasi-Linear Viscoelasticity Using a Discrete Spectrum Approximation
Abstract
The objective of this work was to develop a theoretical and computational framework to apply the finite element method to anisotropic, viscoelastic soft tissues. The quasi-linear viscoelastic (QLV) theory provided the basis for the development. To allow efficient and easy computational implementation, a discrete spectrum approximation was developed for the QLV relaxation function. This approximation provided a graphic means to fit experimental data with an exponential series. A transversely isotropic hyperelastic material model developed for ligaments and tendons was used for the elastic response. The viscoelastic material model was implemented in a general-purpose, nonlinear finite element program. Test problems were analyzed to assess the performance of the discrete spectrum approximation and the accuracy of the finite element implementation. Results indicated that the formulation can reproduce the anisotropy and time-dependent material behavior observed in soft tissues. Application of the formulation to the analysis of the human femur-medial collateral ligament–tibia complex demonstrated the ability of the formulation to analyze large three-dimensional problems in the mechanics of biological joints.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Finite element implementation of incompressible, transversely isotropic hyperelasticity
Weiss, J. A., Maker, B. N., & Govindjee, S. (1996) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/0045-7825(96)01035-3 · Cited by 797
Self-citation
Cited by
Predictors for Traumatic Brain Injuries Evaluated through Accident Reconstructions
Kleiven, S. (2007) · SAE Technical Paper Series · doi:10.4271/2007-22-0003 · Cited by 670
Material Characterization of Human Medial Collateral Ligament
Quapp, K. M., & Weiss, J. A. (1998) · Journal of Biomechanical Engineering · doi:10.1115/1.2834890 · Cited by 351
Self-citationRealistic force feedback for virtual reality based diagnostic surgery simulators
Vuskovic, V., Kauer, M., Szekely, G., & Reidy, M. (2002) · Proceedings 2000 ICRA. Millennium Conference. IEEE International Conference on Robotics and Automation. Symposia Proceedings (Cat. No.00CH37065) · doi:10.1109/robot.2000.844824 · Cited by 71
Orsi, A. D., Chakravarthy, S., Canavan, P. K., Peña, E., Goebel, R., Vaziri, A., & Nayeb-Hashemi, H. (2016) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255842.2015.1043626 · Cited by 24
Metadata
- Authors
- Puso, M. A., & Weiss, J. A.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 1998-02-01
- Volume
- 120
- Issue
- 1
- Pages
- 62-70
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W1967290318
- Cited by
- 231
- References
- 1
- FWCI
- 2.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Finite Element Implementation of Anisotropic Quasi-Linear Viscoelasticity Using a Discrete Spectrum Approximation. https://app.cochat.ai/papers/10.1115/1.2834308
- The paper
- Puso, M. A., & Weiss, J. A. (1998). Finite Element Implementation of Anisotropic Quasi-Linear Viscoelasticity Using a Discrete Spectrum Approximation. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.2834308
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.