Effects of Pulsatile Flow on Cultured Vascular Endothelial Cell Morphology
Abstract
Endothelial cells (EC) appear to adapt their morphology and function to the in vivo hemodynamic environment in which they reside. In vitro experiments indicate that similar alterations occur for cultured EC exposed to a laminar steady-state flow-induced shear stress. However, in vivo EC are exposed to a pulsatile flow environment; thus, in this investigation, the influence of pulsatile flow on cell shape and orientation and on actin microfilament localization in confluent bovine aortic endothelial cell (BAEC) monolayers was studied using a 1-Hz nonreversing sinusoidal shear stress of 40 ± 20 dynes/cm2 (type I), 1-Hz reversing sinusoidal shear stresses of 20 ± 40 and 10 ± 15 dynes/cm2 (type II), and 1-Hz oscillatory shear stresses of 0 ± 20 and 0 ± 40 dynes/cm2 (type III). The results show that in a type I nonreversing flow, cell shape changed less rapidly, but cells took on a more elongated shape than their steady flow controls long-term. For low-amplitude type II reversing flow, BAECs changed less rapidly in shape and were always less elongated than their steady controls; however, for high amplitude reversal, BAECs did not stay attached for more than 24 hours. For type III oscillatory flows, BAEC cell shape remained polygonal as in static culture and did not exhibit actin stress fibers, such as occurred in all other flows. These results demonstrate that EC can discriminate between different types of pulsatile flow environments. Furthermore, these experiments indicate the importance of engineering the cell culture environment so as to include pulsatile flow in investigations of vascular endothelial cell biology, whether these studies are designed to study vascular biology and the role of the endothelial cell in disease processes, or are ones leading to the development of hybrid, endothelial cell-preseeded vascular grafts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Flow-mediated endothelial mechanotransduction
Davies, P. F. (1995) · Physiological Reviews · doi:10.1152/physrev.1995.75.3.519 · Cited by 2,802
Chiu, J.-J., & Chien, S. (2011) · Physiological Reviews · doi:10.1152/physrev.00047.2009 · Cited by 2,280
Ku, D. N. (1997) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.29.1.399 · Cited by 1,477
Intracardiac fluid forces are an essential epigenetic factor for embryonic cardiogenesis
Hove, J. R., Köster, R. W., Forouhar, A. S., Acevedo-Bolton, G., Fraser, S. E., & Gharib, M. (2003) · Nature · doi:10.1038/nature01282 · Cited by 997
Molecular basis of the effects of shear stress on vascular endothelial cells
Li, Y.-S. J., Haga, J. H., & Chien, S. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.09.030 · Cited by 904
Metadata
- Authors
- Helmlinger, G., Geiger, R. V., Schreck, S., & Nerem, R. M.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 1991-05-01
- Volume
- 113
- Issue
- 2
- Pages
- 123-131
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2054312358
- Cited by
- 288
- References
- 0
- FWCI
- 2.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effects of Pulsatile Flow on Cultured Vascular Endothelial Cell Morphology. https://app.cochat.ai/papers/10.1115/1.2891226
- The paper
- Helmlinger, G., Geiger, R. V., Schreck, S., & Nerem, R. M. (1991). Effects of Pulsatile Flow on Cultured Vascular Endothelial Cell Morphology. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.2891226
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.