The DOI matches its Crossref record.
Elementary Mechanics of the Endothelium of Blood Vessels
Abstract
The endothelium lining human arteries is a continuum of endothelial cells. The flowing blood imposes a shear stress on the endothelium. To compute the internal stress in the endothelium, we use two alternative hypotheses: 1) The cell content is fluid-like so that at steady-state it has no shear stress. 2) The cell content is solid-like. Under hypothesis No. 1, the membrane tension in the upper cell membrane grows in the direction opposite to the blood flow at a rate equal to the blood shear stress. At the junction of two neighboring cells the membrane tension in the downstream cell is transmitted partly to the basal lamina, and partly to the upstream cell. The transmission depends on the osmotic or static pressure difference between the cell and blood. If the static pressure difference is zero, the tension in the upper cell membrane will accumulate upstream. At other values of static pressure, the cell membrane tension may increase, decrease, or fluctuate along the vessel depending on the inclination of the side walls of the cells at the junctions. To determine the sidewall inclinations, we propose to use the complementary energy theorem. Under hypothesis No. 2, the cell content can bear shear, which tends to reduce the cell membrane tension; but the cell membrane tension accumulation phenomenon discussed above remains valid. These results are used to analyze the interaction of the cell membrane and cell nucleus; and the effect of turbulences in the flow on causing large fluctuations in cell membrane tension and vertical oscillations of the nuclei. The implication of tensile stress on the permeability of the cell membrane is discussed. We conclude that for the study of mass transport and stress fibers in the endothelial cells, one should consider the interaction of neighboring endothelial cells as a continuum, and shift attention from the shear stress in the blood to the principal stresses in the cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Flow-mediated endothelial mechanotransduction
Davies, P. F. (1995) · Physiological Reviews · doi:10.1152/physrev.1995.75.3.519 · Cited by 2,802
Mechanotransduction at a distance: mechanically coupling the extracellular matrix with the nucleus
Wang, N., Tytell, J. D., & Ingber, D. E. (2009) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2594 · Cited by 1,762
Cell prestress. I. Stiffness and prestress are closely associated in adherent contractile cells
Wang, N., Tolić-Nørrelykke, I. M., Chen, J., Mijailovich, S. M., Butler, J. P., Fredberg, J. J., & Stamenović, D. (2002) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00269.2001 · Cited by 669
Endothelial cation channel PIEZO1 controls blood pressure by mediating flow-induced ATP release
Wang, S., Chennupati, R., Kaur, H., Iring, A., Wettschureck, N., & Offermanns, S. (2016) · Journal of Clinical Investigation · doi:10.1172/jci87343 · Cited by 616
Tensegrity, cellular biophysics, and the mechanics of living systems
Ingber, D. E., Wang, N., & Stamenović, D. (2014) · Reports on Progress in Physics · doi:10.1088/0034-4885/77/4/046603 · Cited by 485
Metadata
- Authors
- Fung, Y. C., & Liu, S. Q.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 1993-02-01
- Volume
- 115
- Issue
- 1
- Pages
- 1-12
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2078902049
- Cited by
- 185
- References
- 0
- FWCI
- 3.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Elementary Mechanics of the Endothelium of Blood Vessels. https://app.cochat.ai/papers/10.1115/1.2895465
- The paper
- Fung, Y. C., & Liu, S. Q. (1993). Elementary Mechanics of the Endothelium of Blood Vessels. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.2895465
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.