CoChat

Scanning Acoustic Microscope Studies of the Elastic Properties of Osteons and Osteon Lamellae

Katz, J. Lawrence, Meunier, Alain · 1993 · Journal of Biomechanical Engineering
Cited by 96

The DOI matches its Crossref record.

Abstract

Scanning acoustic microscopy (SAM) provides the means for studying the elastic properties of a material at a comparable level of resolution to that obtained by optical microscopy for structural studies. SAM is nondestructive and permits observation of properties in the interior of materials which are optically opaque. Two modes of ultrasonic signals have been used in a Model UH3 Scanning Acoustic Microscope (Olympus Co., Tokyo, Japan) as part of a continuing study of the microstructural properties of bone. The pulse mode, using a single narrow pulse in the range of 30 MHz to 100 MHz, has been used to survey the surface and interior of specimens of human and canine femoral compact cortical bone at resolutions down to approximately 30μm. To obtain more detailed information at significantly higher resolution, the burst mode, comprised of tens of sinusoids, has been used at frequencies from 200 MHz to 600 MHz. This has provided details of both human and canine single osteons (or haversion systems) and osteonic lamellae at resolutions down to approximately 1.7μm, well within the thickness of a lamella as viewed in a specimen cut transverse to the femoral axis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1115/1.2895537

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Katz, J. L., & Meunier, A.
Venue
Journal of Biomechanical Engineering
Published
1993-11-01
Volume
115
Issue
4B
Pages
543-548
ISSN
  • 0148-0731 (ISSN-L)
  • 1528-8951
OpenAlex
W2022226853
Cited by
96
References
0
FWCI
3.49
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.