Scanning Acoustic Microscope Studies of the Elastic Properties of Osteons and Osteon Lamellae
The DOI matches its Crossref record.
Abstract
Scanning acoustic microscopy (SAM) provides the means for studying the elastic properties of a material at a comparable level of resolution to that obtained by optical microscopy for structural studies. SAM is nondestructive and permits observation of properties in the interior of materials which are optically opaque. Two modes of ultrasonic signals have been used in a Model UH3 Scanning Acoustic Microscope (Olympus Co., Tokyo, Japan) as part of a continuing study of the microstructural properties of bone. The pulse mode, using a single narrow pulse in the range of 30 MHz to 100 MHz, has been used to survey the surface and interior of specimens of human and canine femoral compact cortical bone at resolutions down to approximately 30μm. To obtain more detailed information at significantly higher resolution, the burst mode, comprised of tens of sinusoids, has been used at frequencies from 200 MHz to 600 MHz. This has provided details of both human and canine single osteons (or haversion systems) and osteonic lamellae at resolutions down to approximately 1.7μm, well within the thickness of a lamella as viewed in a specimen cut transverse to the femoral axis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Zysset, P. K., Edward Guo, X., Edward Hoffler, C., Moore, K. E., & Goldstein, S. A. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00111-6 · Cited by 1,006
Elastic properties of human cortical and trabecular lamellar bone measured by nanoindentation
Rho, J.-Y., Tsui, T. Y., & Pharr, G. M. (1997) · Biomaterials · doi:10.1016/s0142-9612(97)00073-2 · Cited by 924
Lamellar Bone: Structure–Function Relations
Weiner, S., Traub, W., & Wagner, H. D. (1999) · Journal of Structural Biology · doi:10.1006/jsbi.1999.4107 · Cited by 674
Turner, C. H., Rho, J., Takano, Y., Tsui, T. Y., & Pharr, G. M. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00177-8 · Cited by 547
Hengsberger, S., Kulik, A., & Zysset, P. (2002) · Bone · doi:10.1016/s8756-3282(01)00624-x · Cited by 363
Elastic properties of microstructural components of human bone tissue as measured by nanoindentation
Rho, J.-Y., Roy, M. E., Tsui, T. Y., & Pharr, G. M. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199904)45:1<48::aid-jbm7>3.0.co;2-5 · Cited by 348
Rho, J. Y., Zioupos, P., Currey, J. D., & Pharr, G. M. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00199-3 · Cited by 276
Heterogeneity of bone lamellar-level elastic moduli
Hoffler, C. E., Moore, K. E., Kozloff, K., Zysset, P. K., Brown, M. B., & Goldstein, S. A. (2000) · Bone · doi:10.1016/s8756-3282(00)00268-4 · Cited by 259
Anisotropic properties of human tibial cortical bone as measured by nanoindentation
Fan, Z., Swadener, J. G., Rho, J. Y., Roy, M. E., & Pharr, G. M. (2002) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(01)00186-3 · Cited by 254
Variations in the individual thick lamellar properties within osteons by nanoindentation
Rho, J. Y., Zioupos, P., Currey, J. D., & Pharr, G. M. (1999) · Bone · doi:10.1016/s8756-3282(99)00163-5 · Cited by 236
Age-related differences in post-yield damage in human cortical bone. Experiment and model
Courtney, A. C., Hayes, W. C., & Gibson, L. J. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(96)84542-8 · Cited by 131
Metadata
- Authors
- Katz, J. L., & Meunier, A.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 1993-11-01
- Volume
- 115
- Issue
- 4B
- Pages
- 543-548
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2022226853
- Cited by
- 96
- References
- 0
- FWCI
- 3.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.