The DOI matches its Crossref record.
The Influence of Test Conditions on Characterization of the Mechanical Properties of Brain Tissue
Abstract
To understand brain injuries better, the mechanical properties of brain tissue have been studied for 50years; however, no universally accepted data set exists. The variation in material properties reported may be caused by differences in testing methods and protocols used. An overview of studies on the mechanical properties of brain tissue is given, focusing on testing methods. Moreover, the influence of important test conditions, such as temperature, anisotropy, and precompression was experimentally determined for shear deformation. The results measured at room temperature show a stiffer response than those measured at body temperature. By applying the time-temperature superposition, a horizontal shift factor aT=8.5–11 was found, which is in agreement with the values found in literature. Anisotropy of samples from the corona radiata was investigated by measuring the shear resistance for different directions in the sagittal, the coronal, and the transverse plane. The results measured in the coronal and the transverse plane were 1.3 and 1.25 times stiffer than the results obtained from the sagittal plane. The variation caused by anisotropy within the same plane of individual samples was found to range from 25% to 54%. The effect of precompression on shear results was investigated and was found to stiffen the sample response. Combinations of these and other factors (postmortem time, donor age, donor type, etc.) lead to large differences among different studies, depending on the different test conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mechanical characterization of brain tissue in compression at dynamic strain rates
Rashid, B., Destrade, M., & Gilchrist, M. D. (2012) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2012.01.022 · Cited by 426
The impact of aging and gender on brain viscoelasticity
Sack, I., Beierbach, B., Wuerfel, J., Klatt, D., Hamhaber, U., Papazoglou, S., Martus, P., & Braun, J. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.02.040 · Cited by 423
Mechanics of the brain: perspectives, challenges, and opportunities
Goriely, A., Geers, M. G. D., Holzapfel, G. A., Jayamohan, J., Jérusalem, A., Sivaloganathan, S., Squier, W., van Dommelen, J. A. W., Waters, S., & Kuhl, E. (2015) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-015-0662-4 · Cited by 371
Self-citationFifty years of brain tissue mechanical testing: From in vitro to in vivo investigations
Chatelin, S., Constantinesco, A., & Willinger, R. (2010) · Biorheology: The Official Journal of the International Society of Biorheology · doi:10.3233/bir-2010-0576 · Cited by 342
Feng, Y., Okamoto, R. J., Namani, R., Genin, G. M., & Bayly, P. V. (2013) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2013.04.007 · Cited by 316
Metadata
- Authors
- Hrapko, M., van Dommelen, J. A. W., Peters, G. W. M., & Wismans, J. S. H. M.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 2008-04-22
- Volume
- 130
- Issue
- 3
- Pages
- 031003-031003
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2030452070
- Cited by
- 184
- References
- 0
- FWCI
- 6.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Influence of Test Conditions on Characterization of the Mechanical Properties of Brain Tissue. https://app.cochat.ai/papers/10.1115/1.2907746
- The paper
- Hrapko, M., van Dommelen, J. A. W., Peters, G. W. M., & Wismans, J. S. H. M. (2008). The Influence of Test Conditions on Characterization of the Mechanical Properties of Brain Tissue. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.2907746
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.