CoChat

Viscoelastic Stress Analysis of Constrained Proton Exchange Membranes Under Humidity Cycling

Lai, Yeh-Hung, Mittelsteadt, Cortney K., Gittleman, Craig S., Dillard, David A. · 2009 · Journal of Fuel Cell Science and Technology
Cited by 128

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

Many premature failures in proton exchange membrane (PEM) fuel cells are attributed to crossover of the reactant gas from microcracks in the membranes. The formation of these microcracks is believed to result from chemical and/or mechanical degradation of the constrained membrane during fuel cell operation. By characterizing the through-membrane leakage, we report failures resulting from crack formation in several PEMs mounted in 50cm2 fuel cell fixtures and mechanically stressed as the environment was cycled between wet and dry conditions in the absence of chemical potential. The humidity cycling tests also show that the failure from crossover leaks is delayed if membranes are subjected to smaller humidity swings. To understand the mechanical response of PEMs constrained by bipolar plates and subjected to changing humidity levels, we use Nafion® NR-111 as a model membrane and conduct numerical stress analyses to simulate the humidity cycling test. We also report the measurement of material properties required for the stress analysis—water content, coefficient of hygral expansion, and creep compliance. From the creep test results, we have found that the principle of time-temperature-humidity superposition can be applied to Nafion® NR-111 to construct a creep compliance master curve by shifting individual compliance curves with respect to temperature and water content. The stress prediction obtained using the commercial finite element program ABAQUS® agrees well with the stress measurement of Nafion® NR-111 from both tensile and relaxation tests for strains up to 8%. The stress analysis used to model the humidity cycling test shows that the membrane can develop significant residual tensile stress after humidity cycling. The result shows that the larger the humidity swing and/or the faster the hydration/dehydration rate, the higher the residual tensile stress. This result is confirmed experimentally as PEM failure is significantly delayed by decreasing the magnitude of the relative humidity cycle. Based on the current study, we also discuss potential improvements for material characterization, material state diagnostics, and a stress model for PEMs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1115/1.2971045

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 128

Metadata

Authors
Lai, Y.-H., Mittelsteadt, C. K., Gittleman, C. S., & Dillard, D. A.
Venue
Journal of Fuel Cell Science and Technology
Published
2009-02-20
Volume
6
Issue
2
ISSN
  • 1550-624X (ISSN-L)
  • 1551-6989
OpenAlex
W2066465812
Cited by
128
References
7
FWCI
6.60
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Viscoelastic Stress Analysis of Constrained Proton Exchange Membranes Under Humidity Cycling. https://app.cochat.ai/papers/10.1115/1.2971045
The paper
Lai, Y.-H., Mittelsteadt, C. K., Gittleman, C. S., & Dillard, D. A. (2009). Viscoelastic Stress Analysis of Constrained Proton Exchange Membranes Under Humidity Cycling. Journal of Fuel Cell Science and Technology. https://doi.org/10.1115/1.2971045

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.