Effects of Nonlinear Strain-Dependent Permeability and Rate of Compression on the Stress Behavior of Articular Cartilage
Abstract
The compressive viscoelastic behavior of articular cartilage, a fiber-reinforced, porous, permeable solid matrix filled with water, is predominately governed by the flow of the interstitial water within the tissue and its exudation across the articular surface. The fluid flow is in turn governed by the permeability of the tissue and the loading imposed upon its surface. But for articular cartilage, the permeability depends nonlinearly on the strain: k = ko exp(Me). Here, M is the nonlinear flow-limiting parameter and e is the dilatation. In this investigation, we studied the influence of M and Ro = koHA / U˙h (where HA is the elastic equilibrium modulus of the solid matrix, h is the tissue’s thickness and U˙ is the rate of compression applied onto the surface via a rigid, porous, free-draining filter) on the stress history of circular plugs of cartilage specimens attached to the bone. It was found that these two parameters have profound effects on the predicted compressive stress history. For very large Ro, the fluid flow effects become negligible. For small Ro and large M, large instantaneous compressive stresses several times larger than those observed at equilibrium are predicted. This amplification of compressive stress is due to the increase of importance of the relative fluid flow effect, i.e., Ro → 0, and nonlinear flow-limit effect, i.e., M > 0. Also, the theoretical curves predict that the rate of increase of stress initially decreases (convex) and finally becomes a constant. The results of our 5 percent offset compression experiments are in good agreement with the theoretical predictions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fluid transport and mechanical properties of articular cartilage: A review
Mow, V. C., Holmes, M. H., & Michael Lai, W. (1984) · Journal of Biomechanics · doi:10.1016/0021-9290(84)90031-9 · Cited by 1,024
Self-citationBiosynthetic response of cartilage explants to dynamic compression
Sah, R. L. ‐., Kim, Y., Doong, J. H., Grodzinsky, A. J., Plass, A. H. K., & Sandy, J. D. (1989) · Journal of Orthopaedic Research · doi:10.1002/jor.1100070502 · Cited by 875
Depth‐dependent confined compression modulus of full‐thickness bovine articular cartilage
Schinagl, R. M., Gurskis, D., Chen, A. C., & Sah, R. L. (1997) · Journal of Orthopaedic Research · doi:10.1002/jor.1100150404 · Cited by 646
Functional Tissue Engineering: The Role of Biomechanics
Butler, D. L., Goldstein, S. A., & Guilak, F. (2000) · Journal of Biomechanical Engineering · doi:10.1115/1.1318906 · Cited by 624
Akizuki, S., Mow, V. C., Müller, F., Pita, J. C., Howell, D. S., & Manicourt, D. H. (1986) · Journal of Orthopaedic Research · doi:10.1002/jor.1100040401 · Cited by 504
Self-citationBiphasic indentation of articular cartilage—I. Theoretical analysis
Mak, A. F., Lai, W. M., & Mow, V. C. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90036-4 · Cited by 478
Self-citationBUCKWALTER, J. A., & MANKIN, H. J. (1997) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199704000-00021 · Cited by 464
Williamson, A. K., Chen, A. C., & Sah, R. L. (2001) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(01)00052-3 · Cited by 329
Anatomy, Biochemistry, and Physiology of Articular Cartilage
HUBER, M., TRATTNIG, S., & LINTNER, F. (2000) · Investigative Radiology · doi:10.1097/00004424-200010000-00003 · Cited by 304
Measurement of Patellar Tracking: Assessment and Analysis of the Literature
Katchburian, M. V., Bull, A. M. J., Shih, Y.-F., Heatley, F. W., & Amis, A. A. (2003) · Clinical Orthopaedics & Related Research · doi:10.1097/01.blo.0000068767.86536.9a · Cited by 273
Chen, S. S., Falcovitz, Y. H., Schneiderman, R., Maroudas, A., & Sah, R. L. (2001) · Osteoarthritis and Cartilage · doi:10.1053/joca.2001.0424 · Cited by 266
Poroelastic creep response analysis of a lumbar motion segment in compression
Argoubi, M., & Shirazi-Adl, A. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(96)00035-8 · Cited by 266
Chen, A. C., Bae, W. C., Schinagl, R. M., & Sah, R. L. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00170-6 · Cited by 254
Gasik, M., Zühlke, A., Haaparanta, A.-M., Muhonen, V., Laine, K., Bilotsky, Y., Kellomäki, M., & Kiviranta, I. (2018) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2018.00187 · Cited by 24
“, Finland) protocol (Gasik, 2014, 2017a,b), adjusted for simulated cartilage conditions (Hayes and Bodine, 1978; Mow et al., 1980; Lai et al., 1981).”
BackgroundResultInfluential
Metadata
- Authors
- Lai, W. M., Mow, V. C., & Roth, V.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 1981-05-01
- Volume
- 103
- Issue
- 2
- Pages
- 61-66
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2136639415
- Cited by
- 237
- References
- 0
- FWCI
- 4.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.