The DOI matches its Crossref record.
Tensile properties of human knee joint cartilage: I. Influence of ionic conditions, weight bearing, and fibrillation on the tensile modulus
Abstract
The flow‐independent (intrinsic) tensile modulus of the extracellular matrix of human knee joint cartilage has been measured for normal, fibrillated, and osteoarthritic (removed from total knee joint replacements) cartilage. The modulus was determined in our isometric tensile apparatus and measured at equilibrium. We found a linear equilibrium stress‐strain behavior up to ∼15% strain. The modulus was measured for tissues from the high and low weight‐bearing areas of the joint surfaces, the medial femoral condyle and lateral patello femoral groove, and from different zones (surface, subsurface, middle, and middle‐deep) within the tissue. For all specimens, the intrinsic tensile modulus was always less than 30 MPa. Tissues from low weight‐bearing areas (LWA) are stiffer than those from high weight‐bearing areas (HWA). The tensile modulus of the ECM correlates strongly with the collagen/proteoglycan ratio; it is higher for LWA than for HWA. Osteoarthritic cartilage from total knee replacement procedures has a tensile stiffness less than 2 MPa.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Chung, C., & Burdick, J. A. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.08.027 · Cited by 760
Microfluidic platforms for mechanobiology
Polacheck, W. J., Li, R., Uzel, S. G. M., & Kamm, R. D. (2013) · Lab on a Chip · doi:10.1039/c3lc41393d · Cited by 272
Strategic Design and Fabrication of Engineered Scaffolds for Articular Cartilage Repair
Izadifar, Z., Chen, X., & Kulyk, W. (2012) · Journal of Functional Biomaterials · doi:10.3390/jfb3040799 · Cited by 203
Computational aspects in mechanical modeling of the articular cartilage tissue
Mohammadi, H., Mequanint, K., & Herzog, W. (2013) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1177/0954411912470239 · Cited by 28
Metadata
- Authors
- Akizuki, S., Mow, V. C., Müller, F., Pita, J. C., Howell, D. S., & Manicourt, D. H.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 1986-01
- Volume
- 4
- Issue
- 4
- Pages
- 379-392
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W1972325592
- Cited by
- 504
- References
- 0
- FWCI
- 3.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tensile properties of human knee joint cartilage: I. Influence of ionic conditions, weight bearing, and fibrillation on the tensile modulus. https://app.cochat.ai/papers/10.1002/jor.1100040401
- The paper
- Akizuki, S., Mow, V. C., Müller, F., Pita, J. C., Howell, D. S., & Manicourt, D. H. (1986). Tensile properties of human knee joint cartilage: I. Influence of ionic conditions, weight bearing, and fibrillation on the tensile modulus. Journal of Orthopaedic Research. https://doi.org/10.1002/jor.1100040401
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.