The DOI matches its Crossref record.
The Apparent Viscoelastic Behavior of Articular Cartilage—The Contributions From the Intrinsic Matrix Viscoelasticity and Interstitial Fluid Flows
Abstract
Articular cartilage was modeled rheologically as a biphasic poroviscoelastic material. A specific integral-type linear viscoelastic model was used to describe the constitutive relation of the collagen-proteoglycan matrix in shear. For bulk deformation, the matrix was assumed either to be linearly elastic, or viscoelastic with an identical reduced relaxation spectrum as in shear. The interstitial fluid was considered to be incompressible and inviscid. The creep and the rate-controlled stressrelaxation experiments on articular cartilage under confined compression were analyzed using this model. Using the material data available in the literature, it was concluded that both the interstitial fluid flow and the intrinsic matrix viscoelasticity contribute significantly to the apparent viscoelastic behavior of this tissue under confined compression.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The role of interstitial fluid pressurization in articular cartilage lubrication
Ateshian, G. A. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.04.040 · Cited by 533
Articular contact in a three-dimensional model of the knee
Blankevoort, L., Kuiper, J. H., Huiskes, R., & Grootenboer, H. J. (1991) · Journal of Biomechanics · doi:10.1016/0021-9290(91)90019-j · Cited by 520
Soltz, M. A., & Ateshian, G. A. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00105-5 · Cited by 504
Mechano-Electrochemical Properties Of Articular Cartilage: Their Inhomogeneities and Anisotropies
Mow, V. C., & Guo, X. E. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.110701.120309 · Cited by 478
The Role of Tissue Engineering in Articular Cartilage Repair and Regeneration
Zhang, L., Hu, J., & Athanasiou, K. A. (2009) · Critical Reviews™ in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v37.i1-2.10 · Cited by 475
Korhonen, R. K., Laasanen, M. S., Töyräs, J., Rieppo, J., Hirvonen, J., Helminen, H. J., & Jurvelin, J. S. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00052-0 · Cited by 464
Composition and Dynamics of Articular Cartilage: Structure, Function, and Maintaining Healthy State
Cohen, N. P., Foster, R. J., & Mow, V. C. (1998) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.1998.28.4.203 · Cited by 352
Optical and mechanical determination of poisson's ratio of adult bovine humeral articular cartilage
Jurvelin, J. S., Buschmann, M. D., & Hunziker, E. B. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(96)00133-9 · Cited by 344
Mechanical determinants of osteoarthrosis
Radin, E. L., Burr, D. B., Caterson, B., Fyhrie, D., Brown, T. D., & Boyd, R. D. (1991) · Seminars in Arthritis and Rheumatism · doi:10.1016/0049-0172(91)90036-y · Cited by 331
Soltz, M. A., & Ateshian, G. A. (2000) · Journal of Biomechanical Engineering · doi:10.1115/1.1324669 · Cited by 330
Setton, L. A., Zhu, W., & Mow, V. C. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90019-b · Cited by 316
Caligaris, M., & Ateshian, G. A. (2008) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2008.02.020 · Cited by 288
Computational aspects in mechanical modeling of the articular cartilage tissue
Mohammadi, H., Mequanint, K., & Herzog, W. (2013) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1177/0954411912470239 · Cited by 28
Metadata
- Authors
- Mak, A. F.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 1986-05-01
- Volume
- 108
- Issue
- 2
- Pages
- 123-130
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2041099873
- Cited by
- 391
- References
- 0
- FWCI
- 0.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.