The DOI matches its Crossref record.
Yield Behavior of Bovine Cancellous Bone
Abstract
The compressive yield strain was measured for 61 specimens of bovine cancellous bone from three distal femora. There was no significant relationship (p = 0.08, R2 = 0.051) between yield strain and the degree of trabecular orientation. There was a significant positive correlation (p<0.00001, R2 = 0.319) between yield strain and structural (apparent) density and significant negative correlation (p<0.0025, R2 = 0.145) between yield strain and bone density. Yield strain correlated best with bone solid volume fraction Vv (εy = 0.592 + 1.446vv, R2 = 0.337). The quantity, yield strain, is highly dependent on specific definitions of the yield point and the point of zero strain. For this study the yield point was defined by a 0.0003 offset criterion, and the point of zero strain was defined as the point where the tangent at 15 percent of yield crosses zero. The results using these definitions were compared with results using yield strain values determined by other definitions of the yield point and zero strain. The correlations between yield strain and trabecular orientation, structural density and bone density changed very little for differing definitions of yield. The results suggest that yield strain in cancellous bone is isotropic or independent of textural anisotropy, so the yield behavior may be characterized by a maximum strain yield criterion. The results also suggest that the primary mode of yield in cancellous bone is buckling of the trabeculae.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Ultimate strains in trabecular bone also appear to be isotropic and range from 1.0% to 2.5% (97, 99), whereas yield strains range from 0.70% to 0.77% in compression and from 0.65% to 0.71% in tension (82).”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [99]
Citations
Cited by
Sorted by citations
Items 101–129 of 129
Principles of Bone Biomechanics
Turner, C. H., & Burr, D. B. (2006) · Elsevier eBooks · doi:10.1016/b978-0-323-03437-1.50013-0 · Cited by 6
Self-citationIs yield strain in cancellous bone isotropic?
Turner, C. H. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)90059-4 · Cited by 4
Self-citationBiomechanics of Vertebral Fracture
Whyne, C. M., McLachlin, S. D., Burke, M., & Hardisty, M. (2017) · Springer eBooks · doi:10.1007/978-3-319-52634-8_2 · Cited by 3
Abé, H., Hayashi, K., & Sato, M. (1996) · Springer eBooks · doi:10.1007/978-4-431-65862-7_3 · Cited by 3
A 50‐year perspective on the use and potential of artiodactyl calcanei in bone adaptation studies
Skedros, J. G. (2025) · Biological reviews/Biological reviews of the Cambridge Philosophical Society · doi:10.1111/brv.70089 · Cited by 3
Dall’Ara, E., & Cheong, V. S. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-824481-4.00007-x · Cited by 4
Biomaterials: Processing, Characterization, and Applications
Lacroix, D., & Planell, J. A. (2009) · Springer eBooks · doi:10.1007/978-0-387-84872-3_4 · Cited by 2
Januddi, F., Syahrom, A., Harun, M. N., et al. (2013) · Advanced materials research · doi:10.4028/www.scientific.net/amr.845.266 · Cited by 2
“Buckling has also been reported to affect rod-like trabecular in experimental investigation [21].”
BackgroundFang, Z., Ranslow, A. N., Tomas-Medina, P. D., Gunnarsson, A., Weerasooriya, T., Satapathy, S., Thompson, K. A., & Kraft, R. H. (2018) · Journal of Biomechanical Engineering · doi:10.1115/1.4039895 · Cited by 2
Lacroix, D., & Planell, J. A. (2020) · Springer eBooks · doi:10.1007/978-3-030-49206-9_8 · Cited by 3
Orientation of whole bone samples of small rodents matters during bending tests
Ferreño, D., Sainz-Aja, J. A., Carrascal, I., Diego, S., Ruiz, E., Casado, J. A., Riancho, J. A., Sañudo, C., & Gutiérrez-Solana, F. (2016) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2016.08.025 · Cited by 2
Keaveny, T. M., Wachtel, E. F., Ford, C. M., & Hayes, W. C. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)90060-8 · Cited by 2
Bone Strength and Mechanical Behaviour
Troy, K. L., & Collins, C. J. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-822944-6.00061-x · Cited by 1
Yeow, C., Lee, P. V. S., & Goh, J. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.02.036 · Cited by 1
“It is known that excessive compression of cancellous bone can result in trabecular fracture and buckling, which is the main yield mode, and is often reflected by elevated specimen apparent density (Hayes and Carter, 1976; Turner, 1989).”
BackgroundMicrostructure-based numerical computational method for the insertion torque of dental implant
Li, L., Zhang, S., Li, Q., et al. (2019) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2019.06.012 · Cited by 1
Shore, S. W., Unnikrishnan, G. U., Hussein, A. I., & Morgan, E. F. (2012) · CRC Press eBooks · doi:10.1201/b13733-3 · Cited by 6
Analyse des propriétés biomécaniques de l'os à l'échelle macroscopique
Beaupied, H., Lespessailles, É., & Benhamou, C.-L. (2007) · Revue du Rhumatisme · doi:10.1016/j.rhum.2007.02.001 · Cited by 5
Davis, J. M. (2012) · OakTrust (Texas A&M University Libraries) · Cited by 1
Exercise and Bone: Older Adults, Type II Diabetes, and Ketogenic Diets
Scott, M. C. (2021) · doi:10.31390/gradschool_dissertations.5509 · Cited by 1
Pawlikowski, M. (2013) · Prace Naukowe Politechniki Warszawskiej. Mechanika
Experimental and finite element evaluation of bovine lumbar vertebral body stiffness
Sanders, M. M., Dost, S., & Overton, T. R. (2002) · Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.1994.412046
An in vitro study of hydraulic stiffening in cancellous bone
Petrella, A. J., & Hillberry, B. M. (2002) · Proceedings of the ... Southern Biomedical Engineering Conference · doi:10.1109/sbec.1996.493213
A Probabilistic Assessment of Vertebral Cortical Bone Fracture of Intraosteonal Structures
Mabe, I. (2011) · CORE Scholar (Wright State University)
Changes in bone density following exercise training in older adults
Scott, M. C. (2014) · doi:10.31390/gradschool_theses.406
“stress-strain curves examined in human and bovine bone [3-6].”
BackgroundMonotonic and cyclic behaviour of trabecular bone under uniaxial and multiaxial loading
Januddi, M. S., & Januddi, M. A. F. M. S. (2015)
Diagnosis of spine pseudoarthrosis based on the biomechanical properties of bonePreprint
Hipp, J. A., Mikhael, M. M., Reitman, C. A., et al. (2024) · medRxiv · doi:10.1101/2024.01.06.23300551
Gupta, S., Saviour, C. M., Pal, B., Chanda, S., & Mukherjee, K. (2025) · Springer eBooks · doi:10.1007/978-981-96-0586-6_5
The Skeleton and its Adaptation to Gravity
Morey, E. R., Whalen, R. T., Arnaud, S. B., & van der Meulen, M. C. H. (1994) · Comprehensive physiology · doi:10.1002/j.2040-4603.1994.tb01177.x
Metadata
- Authors
- Turner, C. H.
- Affiliations
- Tulane University (US)
- Corresponding author
- Turner, C. H.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 1989-08-01
- Volume
- 111
- Issue
- 3
- Pages
- 256-260
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2082479185
- Cited by
- 127
- References
- 0
- Citations by year
- 2025: 4 · 2024: 1 · 2023: 2 · 2022: 4 · 2021: 3 · 2020: 1 · 2019: 2 · 2018: 4 · 2017: 3 · 2016: 1 · 2015: 4 · 2014: 3 · 2013: 2 · 2012: 5
- FWCI
- 1.64
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Biomechanical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Funders
- U.S. Public Health Service
- National Institute of Dental and Craniofacial Research (DE 06859)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Keywords
- trabecular bone, yield strain, trabecular orientation, bone mineral density, solid volume fraction, yield criterion, distal femur, bovine bone
- MeSH terms
- Animals, Bone and Bones, Cattle, Compliance, Densitometry, Femur, Models, Biological, Stress, Mechanical
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review