Feasibility of an Active Control Scheme for Above Knee Prostheses
The DOI matches its Crossref record.
Abstract
The level walking process for an above knee (A/K) amputee with a conventional prosthesis greatly compromises the amputee’s mobility. The fact that conventional prostheses lock in hyperextension during the stance phase, in contrast to the extend-flexextend pattern during stance for the natural limb, has been suggested as a source of the amputee’s uncosmetic gait and high energy expenditure. While the lock in hyperextension during stance provides stability to prevent buckling, it requires the person to vault over the prosthetic limb. This vaulting during level walking may cause higher vertical displacements of the body center of gravity (c.g.) and accompanying higher energy requirements for the amputee. This investigation employs an amputee-interactive prosthesis simulator system to evaluate the viability of controlling the prosthetic knee joint to follow a normal knee position pattern. In order to insure that the amputee-interactive prosthesis simulator system does not introduce gait anomalies, the system was controlled to simulate a conventional prosthesis. This showed that the simulator system has no undesired side effects since data from walking trials with the simulator system in “conventional prosthesis mode” are very similar to data from conventional prostheses in the literature. Then, an active position control scheme which controls the prosthetic knee joint to follow a normal knee position pattern was tested by two young, active amputees in level walking trials. The subjects experienced very little difficulty in walking with the active control scheme and preferred the simulator with the active control scheme to their conventional prostheses. Measured knee power requirements for the scheme indicate that this type of control is feasible without external power sources. However, measurements of the vertical displacement of the body c.g. show little difference between gait with the active control scheme and gait with a conventional prosthesis. It appears that the increased energy requirements for A/K amputees are not due in total to the lack of the extend-flex-extend position profile at the prosthetic knee joint.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
Design and Control of a Powered Transfemoral Prosthesis
Sup, F., Bohara, A., & Goldfarb, M. (2008) · The International Journal of Robotics Research · doi:10.1177/0278364907084588 · Cited by 586
A Clinical Comparison of Variable-Damping and Mechanically Passive Prosthetic Knee Devices
Johansson, J. L., Sherrill, D. M., Riley, P. O., Bonato, P., & Herr, H. (2005) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/01.phm.0000174665.74933.0b · Cited by 302
Preliminary Evaluations of a Self-Contained Anthropomorphic Transfemoral Prosthesis
Sup, F., Varol, H. A., Mitchell, J., Withrow, T. J., & Goldfarb, M. (2009) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2009.2032688 · Cited by 298
Segal, A. D., Orendurff, M. S., Klute, G. K., McDowell, M. L., Pecoraro, J. A., Shofer, J., & Czerniecki, J. M. (2006) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2005.09.0147 · Cited by 286
Toward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263
Active lower limb prosthetics: a systematic review of design issues and solutions
Windrich, M., Grimmer, M., Christ, O., Rinderknecht, S., & Beckerle, P. (2016) · BioMedical Engineering OnLine · doi:10.1186/s12938-016-0284-9 · Cited by 272
A survey of sensor fusion methods in wearable robotics
Novak, D., & Riener, R. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.012 · Cited by 252
Metadata
- Authors
- Grimes, D. L., Flowers, W. C., & Donath, M.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 1977-11-01
- Volume
- 99
- Issue
- 4
- Pages
- 215-221
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2054173067
- Cited by
- 92
- References
- 0
- FWCI
- 0.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.