The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
FEBio: Finite Elements for Biomechanics
Open accessAbstract
In the field of computational biomechanics, investigators have primarily used commercial software that is neither geared toward biological applications nor sufficiently flexible to follow the latest developments in the field. This lack of a tailored software environment has hampered research progress, as well as dissemination of models and results. To address these issues, we developed the FEBio software suite (http://mrl.sci.utah.edu/software/febio), a nonlinear implicit finite element (FE) framework, designed specifically for analysis in computational solid biomechanics. This paper provides an overview of the theoretical basis of FEBio and its main features. FEBio offers modeling scenarios, constitutive models, and boundary conditions, which are relevant to numerous applications in biomechanics. The open-source FEBio software is written in C++, with particular attention to scalar and parallel performance on modern computer architectures. Software verification is a large part of the development and maintenance of FEBio, and to demonstrate the general approach, the description and results of several problems from the FEBio Verification Suite are presented and compared to analytical solutions or results from other established and verified FE codes. An additional simulation is described that illustrates the application of FEBio to a research problem in biomechanics. Together with the pre- and postprocessing software PREVIEW and POSTVIEW, FEBio provides a tailored solution for research and development in computational biomechanics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Non-linear elastic deformations
Ogden, R. (1984) · Engineering Analysis with Boundary Elements · doi:10.1016/0955-7997(84)90049-3 · Cited by 3,489
Biphasic Creep and Stress Relaxation of Articular Cartilage in Compression: Theory and Experiments
Mow, V. C., Kuei, S. C., Lai, W. M., & Armstrong, C. G. (1980) · Journal of Biomechanical Engineering · doi:10.1115/1.3138202 · Cited by 2,444
Nonlinear Continuum Mechanics for Finite Element Analysis
Bonet, J., & Wood, R. D. (2008) · doi:10.1017/cbo9780511755446 · Cited by 1,824
Solving unsymmetric sparse systems of linear equations with PARDISO
Schenk, O., & Gärtner, K. (2004) · Future Generation Computer Systems · doi:10.1016/j.future.2003.07.011 · Cited by 1,467
Finite Elements of Nonlinear Continua
Oden, J. T. (1971) · International Linear Collider · Cited by 992
Nonlinear Elastic Deformations
Ogden, R. W., & Sternberg, E. (1985) · Journal of Applied Mechanics · doi:10.1115/1.3169137 · Cited by 973
A Supernodal Approach to Sparse Partial Pivoting
Demmel, J. W., Eisenstat, S. C., Gilbert, J. R., Li, X. S., & Liu, J. W. H. (1999) · SIAM Journal on Matrix Analysis and Applications · doi:10.1137/s0895479895291765 · Cited by 840
Finite element implementation of incompressible, transversely isotropic hyperelasticity
Weiss, J. A., Maker, B. N., & Govindjee, S. (1996) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/0045-7825(96)01035-3 · Cited by 797
Self-citationStress-strain data for vulcanised rubber under various types of deformation
Treloar, L. R. G. (1944) · Transactions of the Faraday Society · doi:10.1039/tf9444000059 · Cited by 722
Simo, J. C., & Taylor, R. L. (1991) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/0045-7825(91)90100-k · Cited by 650
An Analysis of the Unconfined Compression of Articular Cartilage
Armstrong, C. G., Lai, W. M., & Mow, V. C. (1984) · Journal of Biomechanical Engineering · doi:10.1115/1.3138475 · Cited by 552
ON FAST FACTORIZATION PIVOTING METHODS FOR SPARSE SYMMETRIC INDEFINITE SYSTEMS
Schenk, O., & Gärtner, K. (2006) · Cited by 431
ON THE SOLUTION OF NONLINEAR FINITE ELEMENT EQUATIONS.
Bathe, K., Dvorkin, E. N., & Kojić, M. (1984) · Cited by 430
Whirley, R. G., & Engelmann, B. E. (1993) · doi:10.2172/10139227 · Cited by 395
Guide for Verification and Validation in Computational Solid Mechanics
Schwer, L. E. (2009) · NCSU Libraries Repository (North Carolina State University Libraries) · Cited by 391
Verification and validation in computational engineering and science: basic concepts
Babuska, I., & Oden, J. T. (2004) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2004.03.002 · Cited by 376
Subject-Specific Finite Element Model of the Pelvis: Development, Validation and Sensitivity Studies
Anderson, A. E., Peters, C. L., Tuttle, B. D., & Weiss, J. A. (2005) · Journal of Biomechanical Engineering · doi:10.1115/1.1894148 · Cited by 347
Self-citationCartilage interstitial fluid load support in unconfined compression
Park, S., Krishnan, R., Nicoll, S. B., & Ateshian, G. A. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00231-8 · Cited by 243
Self-citationVerification, validation and sensitivity studies in computational biomechanics
Anderson, A. E., Ellis, B. J., & Weiss, J. A. (2007) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255840601160484 · Cited by 237
Self-citationValidation of computational models in biomechanics
Henninger, H. B., Reese, S. P., Anderson, A. E., & Weiss, J. A. (2010) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/09544119jeim649 · Cited by 204
Self-citationAn inverse finite-element model of heel-pad indentation
Erdemir, A., Viveiros, M. L., Ulbrecht, J. S., et al. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.03.007 · Cited by 157
Equivalence Between Short-Time Biphasic and Incompressible Elastic Material Responses
Ateshian, G. A., Ellis, B. J., & Weiss, J. A. (2006) · Journal of Biomechanical Engineering · doi:10.1115/1.2720918 · Cited by 143
Self-citationSpilker, R. L., Feinstein, J. A., Parker, D. W., Reddy, V. M., & Taylor, C. A. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9240-3 · Cited by 127
Crawford, R. P., Rosenberg, W. S., & Keaveny, T. M. (2003) · Journal of Biomechanical Engineering · doi:10.1115/1.1589772 · Cited by 124
Finite-Element Model for the Mechanical Behavior of the Left Ventricle
Janz, R. F., & GRIMM, A. F. (1972) · Circulation Research · doi:10.1161/01.res.30.2.244 · Cited by 89
Ateshian, G. A., Maas, S. A., & Weiss, J. A. (2010) · Journal of Biomechanical Engineering · doi:10.1115/1.4001034 · Cited by 65
Self-citationMoore, S. M., Ellis, B. J., Weiss, J. A., McMahon, P. J., & Debski, R. E. (2009) · Annals of Biomedical Engineering · doi:10.1007/s10439-009-9834-7 · Cited by 58
Self-citationLab., C. (. S. L. L. N., Maker, B. N., & USDOE, W. (1995) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · doi:10.2172/110704 · Cited by 17
Research works printed but not linked: 22
- Wang, Imaging of 3D Cardiac Electrical Activity: A Model-Based Recovery Framework, Med. Image Comput. Comput. Assist. Interv., 9, 792, 10.1007/11866565_97 · doi:10.1007/11866565_97
- Speelman, Effects of Wall Calcifications in Patient-Specific Wall Stress Analyses of Abdominal Aortic Aneurysms, J. Biomech. Eng., 129, 105, 10.1115/1.2401189 · doi:10.1115/1.2401189
- Portnoy, Real-Time Patient-Specific Finite Element Analysis of Internal Stresses in the Soft Tissues of a Residual Limb: A New Tool for Prosthetic Fitting, Ann. Biomed. Eng., 35, 120, 10.1007/s10439-006-9208-3 · doi:10.1007/s10439-006-9208-3
- Schmid-Schonbein, Transport Processes in Biomedical Systems: A Roadmap for Future Research Directions, Ann. Biomed. Eng., 33, 1136, 10.1007/s10439-005-5633-y · doi:10.1007/s10439-005-5633-y
- Li, Arthroscopic Evaluation of Cartilage Degeneration Using Indentation Testing—Influence of Indenter Geometry, Clin. Biomech. (Bristol, Avon), 21, 420, 10.1016/j.clinbiomech.2005.12.010 · doi:10.1016/j.clinbiomech.2005.12.010
- Li, Electromechanical Response of Articular Cartilage in Indentation—Considerations on the Determination of Cartilage Properties During Arthroscopy, Comput. Methods Biomech. Biomed. Eng., 8, 83, 10.1080/10255840500167895 · doi:10.1080/10255840500167895
- Davids, A Finite Element Analysis of Endothelial Shear Stress for Pulsatile Blood Flow, Biorheology, 11, 137, 10.3233/BIR-1974-11205 · doi:10.3233/bir-1974-11205
- Doyle, Finite Deformation Analysis of the Relaxed and Contracted Dog Carotid Artery, Microvasc. Res., 3, 400, 10.1016/0026-2862(71)90042-2 · doi:10.1016/0026-2862(71)90042-2
- Matthews, Finite Element Displacement Analysis of a Lung, J. Biomech., 5, 591, 10.1016/0021-9290(72)90031-0 · doi:10.1016/0021-9290(72)90031-0
- Farah, Photoelastic and Finite Element Stress Analysis of a Restored Axisymmetric First Molar, J. Biomech., 6, 511, 10.1016/0021-9290(73)90009-2 · doi:10.1016/0021-9290(73)90009-2
- Belytschko, Finite Element Stress Analysis of an Intervertebral Disc, J. Biomech., 7, 277, 10.1016/0021-9290(74)90019-0 · doi:10.1016/0021-9290(74)90019-0
- Bonet, Nonlinear Continuum Mechanics for Finite Element Analysis, 10.1017/CBO9780511755446 · DOI · Paper page
- Puso, A Stabilized Nodally Integrated Tetrahedral, Int. J. Num. Methods Eng., 67, 841, 10.1002/nme.v67:6 · doi:10.1002/nme.v67:6
- Betsch, A 4-Node Finite Shell Element for the Implementation of General Hyperelastic 3D-Elasticity at Finite Strains, Comput. Methods Appl. Mech. Eng., 130, 57, 10.1016/0045-7825(95)00920-5 · doi:10.1016/0045-7825(95)00920-5
- Laursen, Augmented Lagrangian Quasi-Newton Solver for Constrained Nonlinear Finite Element Applications, Int. J. Numer. Methods Eng., 38, 3571, 10.1002/nme.v38:21 · doi:10.1002/nme.v38:21
- Maker, B. N. , 1995, “Rigid Bodies for Metal Forming Analysis With NIKE3D,” University of California, Lawrence Livermore Laboratory, Report No. UCRL-JC-119862, pp. 1–8.
- Veldhuizen, Will C++ be Faster than FORTRAN? Scientific Computing in Object-Oriented Parallel Environments, Lect. Notes Comput. Sci., 1343, 49, 10.1007/3-540-63827-X_43 · doi:10.1007/3-540-63827-x_43
- Ateshian, Finite Deformation Biphasic Material Properties of Bovine Articular Cartilage From Confined Compression Experiments, J. Biomech., 30, 1157, 10.1016/S0021-9290(97)85606-0 · doi:10.1016/s0021-9290(97)85606-0
- Holmes, Finite Deformation of Soft Tissue: Analysis of a Mixture Model in Uni-Axial Compression, J. Biomech. Eng., 108, 372, 10.1115/1.3138633 · doi:10.1115/1.3138633
- Bisshopp, Large Deflection of Cantilever Beams, Q. Appl. Math., 3, 272, 10.1090/qam/13360 · doi:10.1090/qam/13360
- Batoz, An Explicit Formulation for an Efficient Triangular Plate Bending Element, Int. J. Numer. Methods Eng., 18, 1077, 10.1002/nme.v18:7 · doi:10.1002/nme.v18:7
- Drury, Finding Consistent Strain Distributions in the Glenohumeral Capsule Between Two Subjects: Implications for Physical Examinations, J. Biomech., 44, 607, 10.1016/j.jbiomech.2010.11.018 · doi:10.1016/j.jbiomech.2010.11.018
Cited by
Kupfer, M. E., Lin, W.-H., Ravikumar, V., Qiu, K., Wang, L., Gao, L., Bhuiyan, D. B., Lenz, M., Ai, J., Mahutga, R. R., et al. (2020) · Circulation Research · doi:10.1161/circresaha.119.316155 · Cited by 329
Bian, L., Hou, C., Tous, E., Rai, R., Mauck, R. L., & Burdick, J. A. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2012.09.052 · Cited by 306
Badano, A., Graff, C. G., Badal, A., Sharma, D., Zeng, R., Samuelson, F. W., Glick, S. J., & Myers, K. J. (2018) · JAMA Network Open · doi:10.1001/jamanetworkopen.2018.5474 · Cited by 235
Fibrotic microtissue array to predict anti-fibrosis drug efficacy
Asmani, M., Velumani, S., Li, Y., Wawrzyniak, N., Hsia, I., Chen, Z., Hinz, B., & Zhao, R. (2018) · Nature Communications · doi:10.1038/s41467-018-04336-z · Cited by 137
Chen, Z., Lu, J., Zhang, C., Hsia, I., Yu, X., Marecki, L., Marecki, E., Asmani, M., Jain, S., Neelamegham, S., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-10067-6 · Cited by 64
Metadata
- Authors
- Maas, S. A., Ellis, B. J., Ateshian, G. A., & Weiss, J. A.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 2012-01-01
- Volume
- 134
- Issue
- 1
- Pages
- 011005-011005
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2017950984
- Cited by
- 1,105
- References
- 28
- FWCI
- 26.51
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.