CoChat

Assessment of Infant Movement With a Compact Wireless Accelerometer System

Gravem, D., Singh, M., Chen, C., Rich, J., Vaughan, J., Goldberg, K., Waffarn, F., Chou, P., Cooper, D., Reinkensmeyer, D., Patterson, D. · 2012 · Journal of Medical Devices
Cited by 57

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

There is emerging data that patterns of motor activity early in neonatal life can predict impairments in neuromotor development. However, current techniques to monitor infant movement mainly rely on observer scoring, a technique limited by skill, fatigue, and inter-rater reliability. Consequently, we tested the use of a lightweight, wireless, accelerometer system that measures movement and can be worn by premature babies without interfering with routine care. We hypothesized that this system would be useful in assessing motor activity, in identifying abnormal movement, and in reducing the amount of video that a clinician would need to review for abnormal movements. Ten preterm infants in the NICU were monitored for 1 h using both the accelerometer system and video. A physical therapist trained to recognize cramped-synchronized general movements scored all of the video data by labeling each abnormal movement observed. The parameters of three different computer models were then optimized based on correlating features computed from accelerometer data and the observer’s annotations. The annotations were compared to the model’s prediction on unseen data. The trained observer identified cramped-synchronized general movements in 6 of the 10 infants. The computer models attained between 70% and 90% accuracy when predicting the same observer label for each data point. Our study suggests that mini-accelerometers may prove useful as a clinical tool assessing patterns of movement in preterm infants.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1115/1.4006129

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 57

Metadata

Authors
Gravem, D., Singh, M., Chen, C., Rich, J., Vaughan, J., Goldberg, K., Waffarn, F., Chou, P., Cooper, D., Reinkensmeyer, D., & Patterson, D.
Venue
Journal of Medical Devices
Published
2012-05-14
Volume
6
Issue
2
ISSN
  • 1932-6181 (ISSN-L)
  • 1932-619X
OpenAlex
W2142962877
Cited by
57
References
2
FWCI
1.01
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Assessment of Infant Movement With a Compact Wireless Accelerometer System. https://app.cochat.ai/papers/10.1115/1.4006129
The paper
Gravem, D., Singh, M., Chen, C., Rich, J., Vaughan, J., Goldberg, K., Waffarn, F., Chou, P., Cooper, D., Reinkensmeyer, D., & Patterson, D. (2012). Assessment of Infant Movement With a Compact Wireless Accelerometer System. Journal of Medical Devices. https://doi.org/10.1115/1.4006129

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.