The DOI matches its Crossref record; 152 of the 152 references it cites were found in a registry or an index.
Biomechanics of Cardiac Electromechanical Coupling and Mechanoelectric Feedback
Open accessAbstract
Cardiac mechanical contraction is triggered by electrical activation via an intracellular calcium-dependent process known as excitation–contraction coupling. Dysregulation of cardiac myocyte intracellular calcium handling is a common feature of heart failure. At the organ scale, electrical dyssynchrony leads to mechanical alterations and exacerbates pump dysfunction in heart failure. A reverse coupling between cardiac mechanics and electrophysiology is also well established. It is commonly referred as cardiac mechanoelectric feedback and thought to be an important contributor to the increased risk of arrhythmia during pathological conditions that alter regional cardiac wall mechanics, including heart failure. At the cellular scale, most investigations of myocyte mechanoelectric feedback have focused on the roles of stretch-activated ion channels, though mechanisms that are independent of ionic currents have also been described. Here we review excitation–contraction coupling and mechanoelectric feedback at the cellular and organ scales, and we identify the need for new multicellular tissue-scale model systems and experiments that can help us to obtain a better understanding of how interactions between electrophysiological and mechanical processes at the cell scale affect ventricular electromechanical interactions at the organ scale in the normal and diseased heart.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This process resembles the electromechanical coupling in the mammalian myocardium: cardiac mechanical contraction is triggered by electrical activation via increased cytoplasmic Ca 2+ concentration 54 .”
From Leaf-venation-directed cellular alignment for macroscale cardiac constructs with tissue-like functionalities (2023) · cites this paper as [54]
In the citing paper
“In plants, the leaf veins, consisting of densely packed cells and aligned fibers, allow the transmission of action potentials, which progression was characterized by the rapid propagation of local intracellular Ca 2+ concentration 53,54 .”
From Leaf-venation-directed cellular alignment for macroscale cardiac constructs with tissue-like functionalities (2023) · cites this paper as [54]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cardiac excitation–contraction coupling
Bers, D., & Despa, S. (2002) · Nature · doi:10.1038/415198a · Cited by 4,927
Effects of substrate stiffness on cell morphology, cytoskeletal structure, and adhesion
Yeung, T., Georges, P. C., Flanagan, L. A., Marg, B., Ortiz, M., Funaki, M., Zahir, N., Ming, W., Weaver, V., & Janmey, P. A. (2005) · Cell Motility and the Cytoskeleton · doi:10.1002/cm.20041 · Cited by 2,325
Total Excitation of the Isolated Human Heart
DURRER, D., van Dam, R. T., FREUD, G. E., Janse, M. J., MEIJLER, F. L., & ARZBAECHER, R. C. (1970) · Circulation · doi:10.1161/01.cir.41.6.899 · Cited by 1,779
Regulation of Contraction in Striated Muscle
Gordon, A. M., Homsher, E. E., & Regnier, M. (2000) · Physiological Reviews · doi:10.1152/physrev.2000.80.2.853 · Cited by 1,740
Calcium Cycling and Signaling in Cardiac Myocytes
Bers, D. M. (2007) · Annual Review of Physiology · doi:10.1146/annurev.physiol.70.113006.100455 · Cited by 1,340
Potter, J. D., & Gergely, J. (1975) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)41347-1 · Cited by 920
Engler, A. J., Krieger, C. C., Johnson, C. P., Raab, M., Tang, H., Speicher, D. W., Sanger, J. W., Sanger, J. M., & Discher, D. E. (2008) · Journal of Cell Science · doi:10.1242/jcs.029678 · Cited by 893
Calcium Induced Release of Calcium from the Sarcoplasmic Reticulum of Skinned Skeletal Muscle Fibres
Endo, M., Tanaka, M., & Ogawa, Y. (1970) · Nature · doi:10.1038/228034a0 · Cited by 818
Elfgang, C., Eckert, R., Lichtenberg‐Fraté, H., Butterweck, A., Traub, O., Klein, R. A., Hülser, D. F., & Willecke, K. (1995) · The Journal of Cell Biology · doi:10.1083/jcb.129.3.805 · Cited by 813
Grines, C. L., Bashore, T. M., Boudoulas, H. K., Olson, S., Shafer, P., & Wooley, C. F. (1989) · Circulation · doi:10.1161/01.cir.79.4.845 · Cited by 741
Cited by
Sorted by citations
Three-dimensional cardiac computational modelling: methods, features and applications.
Lopez-Perez, A., Sebastian, R., & Ferrero, J. M. (2015) · BioMedical Engineering OnLine · doi:10.1186/s12938-015-0033-5 · Cited by 151
Lee, J., Manoharan, V., Cheung, L., Lee, S., Cha, B.-H., Newman, P. L. H., Farzad, R., Mehrotra, S., Zhang, K., Khan, F., et al. (2019) · ACS Nano · doi:10.1021/acsnano.9b03050 · Cited by 150
Cardiomyocyte calcium handling in health and disease: Insights from in vitro and in silico studies
Sutanto, H., Lyon, A., Lumens, J., Schotten, U., Dobrev, D., & Heijman, J. (2020) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2020.02.008 · Cited by 123
Piezoelectric nanogenerators for self‐powered wearable and implantable bioelectronic devices
Das, K. K., Basu, B., Maiti, P., & Dubey, A. K. (2023) · Acta Biomaterialia · doi:10.1016/j.actbio.2023.08.057 · Cited by 105
Biomechanics of Cardiac Function
Voorhees, A. P., & Han, H. (2015) · Comprehensive physiology · doi:10.1002/cphy.c140070 · Cited by 92
Metadata
- Authors
- Pfeiffer, E. R., Tangney, J. R., Omens, J. H., & McCulloch, A. D.
- Affiliations
- University of California San Diego (US)
- Corresponding author
- McCulloch, Andrew D.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 2014-02-01
- Volume
- 136
- Issue
- 2
- Pages
- 021007-021007
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- PMC
- PMC4023651
- OpenAlex
- W2028446666
- Cited by
- 131
- References
- 152
- Citations by year
- 2026: 7 · 2025: 11 · 2024: 10 · 2023: 15 · 2022: 11 · 2021: 13 · 2020: 13 · 2019: 12 · 2018: 7 · 2017: 8 · 2016: 8 · 2015: 11 · 2014: 4
- FWCI
- 1.31
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Journal of Biomechanical Engineering (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Heart, Lung, and Blood Institute (R01HL105242)
- National Institute of General Medical Sciences
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Function and Risk Factors
- Keywords
- mechano-electric feedback, excitation-contraction coupling, intracellular calcium homeostasis, heart failure, electrical dyssynchrony, ventricular arrhythmias, stretch-activated channels, cardiomyocytes, ventricular mechanics
- MeSH terms
- Animals, Heart Conduction System, Humans, Models, Cardiovascular, Myocardial Contraction, Ventricular Function, Feedback, Physiological, Myocytes, Cardiac, Excitation Contraction Coupling
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review