Biologically Inspired Soft Robot for Thumb Rehabilitation1

Abstract

More than 130,000 people have strokes each year in the United States [1]. Of these victims, 76% are left with disabilities that cost the nation over $54 billion in lost work and medical fees. One prominent disability is upper extremity hemiplegia, which occurs among approximately 50% of stroke sufferers [2]. Robotic technology has the potential to provide an automated platform for controled rehabilitation and assisted, task-oriented therapy.Several systems have been designed to assist in patient articulation of an impaired hand using rigid robotic components. While these products have been successful in articulating the pure bending motions of the four fingers, the limited capabilities of rigid technologies fail to reproduce the complicated motion path [3] of the thumb during opposition grasp (see Fig. 1). This is the most important articulation for normal hand function and specifically for picking up everyday objects. To date, robotic systems for thumb rehabilitation have not been widely investigated [4] apart from some recent work [5] that used a multijoint rigid robot.The soft robotic thumb rehabilitation system presented in this paper is a task-oriented therapeutic device that replicates and restores correct thumb motor function for patients with neurologically caused hand disabilities.Discussions with physical therapists and patients identified a need for a controllable robotic system to assist a neurologically impaired thumb in performing functional operations for at-home task-oriented therapy. First and foremost, the device must follow the motion path of a healthy thumb. The device must also be comfortable, durable, and externally controllable. The final design (see Fig. 2) consisted of a soft robotic actuator, a conformable neoprene padded aluminum attachment with Velcro straps, and a control system.The most essential specification of the design was replicating a healthy thumb's natural motion path during opposition grasp. It was hypothesized that the overall motion path of the thumb during opposition grasp could be represented as a combination of bend (thumb flexion), twist (thumb rotation), and extension (skin stretching). A biological kinematic study using eight independent electromagnetic sensors (3D Guidance TrakSTAR) was performed on a healthy thumb during opposition grasp to the index finger and to the small finger. The motion paths measured were broken down into bend, twist, and extension, and their values became the minimum and maximum functional requirements respectively. These requirements were: 25–70 degrees of bend, 15–25 degrees of twist, and 0.4–0.5 in. of linear extension.Given the inherent limitations of traditional robotic components, soft multimaterial fluidic actuators were investigated for their increased compliance, customizability, and safety. Several different soft robotic actuators exist and were evaluated. For this application, a fiber-reinforced actuator was found to be the most effective and efficient in terms of single actuator durability, force, and motion path customizability.The fiber-reinforced actuator was made from an elastomeric chamber with a flexible strain layer (fiberglass cloth, FG-C0427S, US Composites, FL, USA) adhered to the bottom, which was then wrapped with a strain material (Kevlar thread, KEV693NATL00S, The Thread Exchange, NC, USA) to restrict expansion in certain directions, and covered with a flexible outer protection layer. A cross sectional model of a basic, soft bending, fiber-reinforced actuator can be seen in Fig. 3, exhibiting the inner chamber, the structural elastomer, the strain wrapping, the strain layer, and the protective outer layer.Through experimentation, a fabrication technique was developed to create soft actuators with a maximum inflatable pressure of 50 psi (345 kPa) capable of producing the desired bend, twist, and extension motion paths. An actuator with double helical strain wrapping and a strain layer along the bottom produced a bending motion. An actuator with a single helical strain wrapping and a strain layer along the bottom produced a twisting motion.The actuators were segmented and combined in series to produce a single actuator with an overall motion path that was the linear sum of the component contributions from each segment. Consistent with the functional requirements, the final actuator was designed to mimic the overall motion path of a healthy thumb during opposition grasp while positioned along the top surface of an impaired thumb (see Fig. 4).The actuator was integrated into a lightweight hand fixation system consisting of a conformable neoprene-padded aluminum plate with Velcro straps around the palm for rigid attachment to the hand. Three small Velcro straps attached the proximal end of the actuator firmly to the thumb itself to apply articulation force to the appendage (see Fig. 5).A compact control box enabled portability and in-home use of the system. The pressure from an external compressor was transferred

Overview

Integrity signals

Registry

Crossref · 10.1115/1.4027031

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 4 references

Research works printed but not linked: 2

  1. 2007, Therapeutic Robots for Upper-Limb Movement
  2. 2013, A Pediatric Robotic Thumb Exoskeleton for at-Home Rehabilitation

Cited by

See all 111

Metadata

Authors
Maeder-York, P., Clites, T., Boggs, E., Neff, R., Polygerinos, P., Holland, D., Stirling, L., Galloway, K., Wee, C., & Walsh, C.
Affiliations
  • Harvard University (US)
  • Spaulding Hospital (US)
Venue
Journal of Medical Devices
Published
2014-04-28
Volume
8
Issue
2
ISSN
  • 1932-6181 (ISSN-L)
  • 1932-619X
OpenAlex
W1975592148
Cited by
110
References
4
Citations by year
2026: 2 · 2025: 6 · 2024: 11 · 2023: 10 · 2022: 11 · 2021: 11 · 2020: 10 · 2019: 5 · 2018: 14 · 2017: 7 · 2016: 10 · 2015: 10 · 2014: 2
FWCI
9.39
Type
journal article
Language
en
Open access
closed
Locations
Journal of Medical Devices (publishedVersion)
Funders
  • Harvard School of Engineering and Applied Sciences
  • Hansjörg Wyss Institute for Biologically Inspired Engineering, Harvard University
Topics
  • Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
  • Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
  • Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
Keywords
soft robotics, stroke, task-oriented therapy, home-based rehabilitation, electromagnetic tracking, biologically inspired design, control system design

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Biologically Inspired Soft Robot for Thumb Rehabilitation1. https://app.cochat.ai/papers/10.1115/1.4027031
The paper
Maeder-York, P., Clites, T., Boggs, E., Neff, R., Polygerinos, P., Holland, D., Stirling, L., Galloway, K., Wee, C., & Walsh, C. (2014). Biologically Inspired Soft Robot for Thumb Rehabilitation1. Journal of Medical Devices. https://doi.org/10.1115/1.4027031

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.