CoChat

Theoretical Development and Experimental Validation of an Adaptive Controller for Tremor Suppression at Musculoskeletal Level

Taheri, Behzad, Case, David, Richer, Edmond · 2013 · Volume 2: Control, Monitoring, and Energy Harvesting of Vibratory Systems; Cooperative and Networked Control; Delay Systems; Dynamical Modeling and Diagnostics in Biomedical Systems; Estimation and Id of Energy Systems; Fault Detection; Flow and Thermal Systems; Haptics and Hand Motion; Human Assistive Systems and Wearable Robots; Instrumentation and Characterization in Bio-Systems; Intelligent Transportation Systems; Linear Systems and Robust Control; Marine Vehicles; Nonholonomic Systems
Cited by 11

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Tremor is a rhythmical and involuntary oscillatory movement of a body part. Mechanical loading via wearable exoskeletons is a non-invasive tremor suppression alternative to medical treatments. In this approach, the challenge is attenuating the tremor without affecting the patient’s intentional motion. An adaptive tremor suppression algorithm was designed to estimate and restrict motion within the tremor frequency band. An experimental setup was designed and developed to simulate the dynamics of a human arm joint with intentional and tremorous motion. The required orthotic suppressive force was applied via a pneumatic cylinder. The algorithm was implemented with a real-time controller and experimental results show tracking of the tremor frequency and a 97% reduction of tremor amplitude at the fundamental frequency.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1115/dscc2013-3954

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 11

Metadata

Authors
Taheri, B., Case, D., & Richer, E.
Venue
Volume 2: Control, Monitoring, and Energy Harvesting of Vibratory Systems; Cooperative and Networked Control; Delay Systems; Dynamical Modeling and Diagnostics in Biomedical Systems; Estimation and Id of Energy Systems; Fault Detection; Flow and Thermal Systems; Haptics and Hand Motion; Human Assistive Systems and Wearable Robots; Instrumentation and Characterization in Bio-Systems; Intelligent Transportation Systems; Linear Systems and Robust Control; Marine Vehicles; Nonholonomic Systems
Published
2013-10-21
OpenAlex
W1970884720
Cited by
11
References
5
FWCI
1.98
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Theoretical Development and Experimental Validation of an Adaptive Controller for Tremor Suppression at Musculoskeletal Level. https://app.cochat.ai/papers/10.1115/dscc2013-3954
The paper
Taheri, B., Case, D., & Richer, E. (2013). Theoretical Development and Experimental Validation of an Adaptive Controller for Tremor Suppression at Musculoskeletal Level. Volume 2: Control, Monitoring, and Energy Harvesting of Vibratory Systems; Cooperative and Networked Control; Delay Systems; Dynamical Modeling and Diagnostics in Biomedical Systems; Estimation and Id of Energy Systems; Fault Detection; Flow and Thermal Systems; Haptics and Hand Motion; Human Assistive Systems and Wearable Robots; Instrumentation and Characterization in Bio-Systems; Intelligent Transportation Systems; Linear Systems and Robust Control; Marine Vehicles; Nonholonomic Systems. https://doi.org/10.1115/dscc2013-3954

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.