CoChat

Characterization of Parkinsonian Hand Tremor and Validation of a High-Order Tremor Estimator

Zhou, Y., Jenkins, M. E., Naish, M. D., Trejos, A. L. · 2018 · IEEE Transactions on Neural Systems and Rehabilitation Engineering

The DOI matches its Crossref record; 59 of the 72 references it cites were found in a registry or an index.

Abstract

Recent progress in wearable technology has made wearable tremor suppression devices (WTSDs) for Parkinson's patients a potentially viable alternative solution for tremor management. So far, in contrast to wrist and elbow tremor, finger tremors have not been studied in depth despite the huge impact that they have on a patient's daily life. In addition, more evidence has been found showing that the performance of current tremor estimators may be limited by their model order due to the multiple harmonics present in tremor. The aim of this paper is to characterize finger and wrist tremor in both the time and frequency domains, and to propose a high-order tremor estimation algorithm. Tremor magnitudes are reported in the forms of linear acceleration, angular velocity, and angular displacement. The activation of forearm flexor and extensor muscles is also investigated. The frequency analysis shows that Parkinsonian tremors produce oscillations of the hand with pronounced harmonics. At last, a high-order weighted-frequency Fourier linear combiner (WFLC)-based Kalman filter is proposed. The percentage estimation accuracy achieved from the proposed estimator is 96.3 ± 1.7%, showing average improvements of 28.5% and 48.9% over its lower-order counterpart and the WFLC. The proposed estimator shows promise for use in a WTSD.

Overview

Integrity signals

Registry

Crossref · 10.1109/tnsre.2018.2859793

Cites

59 of 59 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 59 references

Research works printed but not linked: 5

  1. gonzález, 1995, A new approach to suppressing abnormal tremor through signal equalization, Proc RESNA Annu Conf, 707
  2. rocon, 2005, Estimation of biomechanical characteristics of tremorous movements based on gyroscopes, Virtual Reality and Assistive Technology, 138
  3. elble, 1990, Tremor, 54
  4. pons, 2012, A wearable neuroprosthesis for the suppression of pathological tremor, IEEE Life Sci Newslett
  5. 2012, Android SDK

Cited by

See all 42

Metadata

Authors
Zhou, Y., Jenkins, M. E., Naish, M. D., & Trejos, A. L.
Affiliations
Western University (CA)
Venue
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Published
2018-09
Volume
26
Issue
9
Pages
1823-1834
ISSN
  • 1534-4320 (ISSN-L)
  • 1558-0210
OpenAlex
W2883932938
Cited by
42
References
72
Citations by year
2026: 2 · 2025: 6 · 2024: 5 · 2023: 5 · 2022: 9 · 2021: 7 · 2020: 6 · 2019: 2
FWCI
1.98
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
  • PubMed (publishedVersion)
  • Scholarship@Western (Western University) (submittedVersion)
Funders
  • Western University
  • Natural Sciences and Engineering Research Council of Canada (RGPIN-2014-03815)
  • Ontario Ministry of Economic Development, Trade and Employment and the Ontario Ministry of Research and Innovation through the Early Researcher Award
  • Peter C. Maurice Research Fellowship in Biomedical Engineering
Topics
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
  • Health Sciences › Medicine › Clinical Neurology › Deep Brain Stimulation and Movement Disorders
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Effects of Vibration on Health
Keywords
finger tremor, Kalman filter
MeSH terms
Wearable Electronic Devices, Aged, Aged, 80 and over, Algorithms, Biomechanical Phenomena, Elbow, Female, Fingers, Fourier Analysis, Hand, Humans, Male, Middle Aged, Tremor, Wrist, Reproducibility of Results, Parkinsonian Disorders

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Characterization of Parkinsonian Hand Tremor and Validation of a High-Order Tremor Estimator. https://app.cochat.ai/papers/10.1109/tnsre.2018.2859793
The paper
Zhou, Y., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2018). Characterization of Parkinsonian Hand Tremor and Validation of a High-Order Tremor Estimator. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2018.2859793

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.