Characterization of Parkinsonian Hand Tremor and Validation of a High-Order Tremor Estimator
The DOI matches its Crossref record; 59 of the 72 references it cites were found in a registry or an index.
Abstract
Recent progress in wearable technology has made wearable tremor suppression devices (WTSDs) for Parkinson's patients a potentially viable alternative solution for tremor management. So far, in contrast to wrist and elbow tremor, finger tremors have not been studied in depth despite the huge impact that they have on a patient's daily life. In addition, more evidence has been found showing that the performance of current tremor estimators may be limited by their model order due to the multiple harmonics present in tremor. The aim of this paper is to characterize finger and wrist tremor in both the time and frequency domains, and to propose a high-order tremor estimation algorithm. Tremor magnitudes are reported in the forms of linear acceleration, angular velocity, and angular displacement. The activation of forearm flexor and extensor muscles is also investigated. The frequency analysis shows that Parkinsonian tremors produce oscillations of the hand with pronounced harmonics. At last, a high-order weighted-frequency Fourier linear combiner (WFLC)-based Kalman filter is proposed. The percentage estimation accuracy achieved from the proposed estimator is 96.3 ± 1.7%, showing average improvements of 28.5% and 48.9% over its lower-order counterpart and the WFLC. The proposed estimator shows promise for use in a WTSD.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The evaluation showed that the eHWFLC-KF achieved better performance than its lower-order counterpart, since parkinsonian tremor consists of multiple frequencies [24], [30].”
From Real-Time Performance Assessment of High-Order Tremor Estimators Used in a Wearable Tremor Suppression Device (2022) · cites this paper as [29]
In the citing paper
“only 11 out of 18 postural tremor datasets present multiple harmonics [29]”
From Real-Time Performance Assessment of High-Order Tremor Estimators Used in a Wearable Tremor Suppression Device (2022) · cites this paper as [29]
In the citing paper
“Furthermore, their proposed feature of adaptively selecting a tremor frequency band is unnecessary in this application, as the frequency band of pathological tremor is well determined and fairly constant [29], [35].”
From Real-Time Performance Assessment of High-Order Tremor Estimators Used in a Wearable Tremor Suppression Device (2022) · cites this paper as [29]
In the citing paper
“most of the parkinsonian resting tremor (17 out of 18 datasets) contains multiple harmonics [29]”
From Real-Time Performance Assessment of High-Order Tremor Estimators Used in a Wearable Tremor Suppression Device (2022) · cites this paper as [29]
Citations
Cites
Goetz, C. G., Tilley, B. C., Shaftman, S. R., Stebbins, G. T., Fahn, S., Martinez‐Martin, P., Poewe, W., Sampaio, C., Stern, M. B., Dodel, R., et al. (2008) · Movement Disorders · doi:10.1002/mds.22340 · Cited by 7,536
Consensus Statement of the Movement Disorder Society on Tremor
Deuschl, G., Bain, P., & Brin, M. (2008) · Movement Disorders · doi:10.1002/mds.870131303 · Cited by 1,981 · cited 1×
“to stay constant with slight variations; however, the amplitude of the tremor varies from person to person [1], [26], [32], [33].”
BackgroundMorgan, D. (1986) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1986.1164869 · Cited by 1,681
Rascol, O., Brooks, D. J., Korczyn, A. D., De Deyn, P. P., Clarke, C. E., & Lang, A. E. (2000) · New England Journal of Medicine · doi:10.1056/nejm200005183422004 · Cited by 1,539
Design and Validation of a Rehabilitation Robotic Exoskeleton for Tremor Assessment and Suppression
Rocon, E., Belda-Lois, J. M., Ruiz, A. F., Manto, M., Moreno, J. C., & Pons, J. L. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903917 · Cited by 349 · cited 1×
“In most of the previous studies [24], [59], parkinsonian tremor was considered and reported as a mono-harmonic signal, its fundamental frequency lying within the range of 4 to 12 Hz.”
ResultAdaptive cancelling of physiological tremor for improved precision in microsurgery
Riviere, C. N., Rader, R. S., & Thakor, N. V. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.686791 · Cited by 260 · cited 3×
“studies [21], [30], [42]–[44], [51] the WFLC was used to estimate only the fundamental frequency.”
BackgroundMethodThe dynamics of resting and postural tremor in Parkinson's disease
Vaillancourt, D. E., & Newell, K. M. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00467-3 · Cited by 210 · cited 2×
“This result is in line with the results from other studies [54], [60].”
BackgroundResultAdaptive Fourier estimation of time-varying evoked potentials
Vaz, C. A., & Thakor, N. V. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.18751 · Cited by 159
Preventing levodopa-induced dyskinesias.
Olanow, C. W., & Obeso, J. A. (2000) · PubMed · Cited by 154
Attenuation of pathological tremors by functional electrical stimulation I: Method
Prochazka, A., Elek, J., & Javidan, M. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368521 · Cited by 150 · cited 2×
“that applies functional electrical stimulation [16]–[23].”
Background
Research works printed but not linked: 5
- gonzález, 1995, A new approach to suppressing abnormal tremor through signal equalization, Proc RESNA Annu Conf, 707
- rocon, 2005, Estimation of biomechanical characteristics of tremorous movements based on gyroscopes, Virtual Reality and Assistive Technology, 138
- elble, 1990, Tremor, 54
- pons, 2012, A wearable neuroprosthesis for the suppression of pathological tremor, IEEE Life Sci Newslett
- 2012, Android SDK
Cited by
Smartwatch for the analysis of rest tremor in patients with Parkinson's disease
Blanco, R. L., Velasco, M. A., Méndez-Guerrero, A., Romero, J. P., del Castillo, M. D., Serrano, J. I., Rocón, E., & Benito‐León, J. (2019) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2019.04.011 · Cited by 95
Design and Preliminary Performance Assessment of a Wearable Tremor Suppression Glove
Zhou, Y., Ibrahim, A. H., Hardy, K. G., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3080622 · Cited by 37
Self-citationReal-Time Voluntary Motion Prediction and Parkinson’s Tremor Reduction Using Deep Neural Networks
Ibrahim, A. H., Zhou, Y., Jenkins, M. E., Trejos, A. L., & Naish, M. D. (2021) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2021.3097007 · Cited by 34
Self-citationMenguc, E. C., cnar, S., Xiang, M., & P. Mandic, D. (2021) · IEEE Signal Processing Letters · doi:10.1109/lsp.2021.3097279 · Cited by 25
Peripherical Electrical Stimulation for Parkinsonian Tremor: A Systematic Review
Meng, L., Jin, M., Zhu, X., & Ming, D. (2022) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2022.795454 · Cited by 29
Metadata
- Authors
- Zhou, Y., Jenkins, M. E., Naish, M. D., & Trejos, A. L.
- Affiliations
- Western University (CA)
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2018-09
- Volume
- 26
- Issue
- 9
- Pages
- 1823-1834
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2883932938
- Cited by
- 42
- References
- 72
- Citations by year
- 2026: 2 · 2025: 6 · 2024: 5 · 2023: 5 · 2022: 9 · 2021: 7 · 2020: 6 · 2019: 2
- FWCI
- 1.98
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
- PubMed (publishedVersion)
- Scholarship@Western (Western University) (submittedVersion)
- Funders
- Western University
- Natural Sciences and Engineering Research Council of Canada (RGPIN-2014-03815)
- Ontario Ministry of Economic Development, Trade and Employment and the Ontario Ministry of Research and Innovation through the Early Researcher Award
- Peter C. Maurice Research Fellowship in Biomedical Engineering
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Health Sciences › Medicine › Clinical Neurology › Deep Brain Stimulation and Movement Disorders
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Effects of Vibration on Health
- Keywords
- finger tremor, Kalman filter
- MeSH terms
- Wearable Electronic Devices, Aged, Aged, 80 and over, Algorithms, Biomechanical Phenomena, Elbow, Female, Fingers, Fourier Analysis, Hand, Humans, Male, Middle Aged, Tremor, Wrist, Reproducibility of Results, Parkinsonian Disorders
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Characterization of Parkinsonian Hand Tremor and Validation of a High-Order Tremor Estimator. https://app.cochat.ai/papers/10.1109/tnsre.2018.2859793
- The paper
- Zhou, Y., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2018). Characterization of Parkinsonian Hand Tremor and Validation of a High-Order Tremor Estimator. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2018.2859793
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.