The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
The measurement and analysis of Parkinsonian hand tremor
Abstract
The study of the mechanical characteristics of tremor for patients suffering from Parkinson's disease (PD) is an important first step to the design of mechanical tremor suppression orthoses. So far, researchers have interpreted tremor characteristics in both the time and the frequency domains. A number of tremor suppression devices have been developed on the basis of these interpretations of tremor. However, most of the studies and devices have only focused on tremor at the wrist and elbow, and have neglected finger tremor despite the huge impact that it has on a patient's daily life. The aim of the present study was to determine the characteristics of finger tremor and wrist tremor, which may be used to provide a reference for the design of tremor suppression devices for the hand. Tremor magnitudes were represented in the forms of linear acceleration, angular velocity and angular displacement. The results show that PD tremors from all joints have a common multiple-frequency pattern and that the second harmonic (6.9-11.5 Hz) makes a large contribution to the tremor that cannot be neglected.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Parkinsonian tremor consists of multiple frequencies.
“The evaluation showed that the eHWFLC-KF achieved better performance than its lower-order counterpart, since parkinsonian tremor consists of multiple frequencies [24], [30].”
From Real-Time Performance Assessment of High-Order Tremor Estimators Used in a Wearable Tremor Suppression Device (2022) · cites this paper as [30]
Citations
Cites
The dynamics of resting and postural tremor in Parkinson's disease
Vaillancourt, D. E., & Newell, K. M. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00467-3 · Cited by 210
Flagged first, then by citations
Research works printed but not linked: 14
- 10.1016/j.parkreldis.2007.09.004 · DOI
- bó, 2008, Online pathological tremor characterization using extended Kalman filtering, Proceedings of the 30th International Conference of the IEEE Engineering in Medicine and Biology Society, 1753
- 0, Google (2012 December) Android SDK
- kazi, 2010, Experimental implementation of smart glove incorporating piezoelectric actuator for hand tremor control, WSEAS Transactions on Systems and Control, 5, 443
- 10.1109/TMECH.2011.2151204 · DOI
- 10.1533/abbi.2004.0038 · DOI · Paper page
- rosen, 1981, The effect of mechanical impedance on abnormal intention tremor, Proceedings of the 9th Annual Northeast Bioengineering Conference, 205
- 10.1056/NEJM200005183422004 · DOI · Paper page
- 10.1109/ROBOT.2005.1570451 · DOI · Paper page
- 10.1177/0954411913494325 · DOI
- 10.1109/ICSMC.2011.6083728 · DOI
- 10.1136/jnnp.2007.131045 · DOI · Paper page
- 10.1001/jama.2014.1397 · DOI
- 10.1115/DSCC2013-3954 · DOI
Cited by
Sorted by citations
Zhou, Y., Naish, M. D., Jenkins, M. E., & Trejos, A. L. (2017) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2016.12.009 · Cited by 46
Self-citationCharacterization of Parkinsonian Hand Tremor and Validation of a High-Order Tremor Estimator
Zhou, Y., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2859793 · Cited by 42
Self-citationZhou, Y., Habibollahi, Z., Ibrahim, A., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2022) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2022.3211450 · Cited by 8
Self-citation
Metadata
- Authors
- Zhou, Y., Jenkins, M. E., Naish, M. D., & Trejos, A. L.
- Affiliations
- Western University (CA)
- Venue
- 2016 IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI)
- Publisher
- IEEE
- Published
- 2016-02
- Pages
- 414-417
- ISSN
- 2641-3590 (ISSN-L)
- OpenAlex
- W2343057921
- Cited by
- 33
- References
- 1
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 1 · 2023: 3 · 2022: 2 · 2021: 5 · 2020: 4 · 2019: 3 · 2018: 7 · 2017: 3 · 2016: 1
- FWCI
- 8.00
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI ...) (publishedVersion)
- Scholarship@Western (Western University) (submittedVersion)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Health Sciences › Medicine › Clinical Neurology › Deep Brain Stimulation and Movement Disorders
- Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
- Keywords
- Parkinson's disease, hand tremor, finger tremor, second harmonic, angular velocity, angular displacement, linear acceleration
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review