Thermal conductivity of thin films: Measurements and understanding
Abstract
Several techniques are reviewed with which thermal conductivity and phonon scattering can be measured in films of thicknesses ranging from angstroms to millimeters. Recent experimental results are compared critically with previous measurements. It is shown that phonons are very sensitive probes of the structural perfection of the films.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The thermal conductivity of a 25 μm-thick film of a-Si:H prepared on an Al substrate was measured using a line 5 μm wide.
“For example, the thermal conductivity of a 25 μm-thick film of a-Si:H prepared on an Al substrate was measured using a line 5 μm wide.8”
From Thermal conductivity measurement from 30 to 750 K: the 3ω method (1990) · cites this paper as [8]
The ability to test the 3ω method at the surface of a bulk sample with a known thermal conductivity adds to the reliability of data on evaporated thin films.
“My ability to test the 3ω method at the surface of a bulk sample with a known thermal conductivity adds to the reliability of data on evaporated thin films. 7,8”
From Thermal conductivity measurement from 30 to 750 K: the 3ω method (1990) · cites this paper as [8]
Cited by
Sorted by citations
Thermal conductivity measurement from 30 to 750 K: the 3ω method
Cahill, D. G. (1990) · Review of Scientific Instruments · doi:10.1063/1.1141498 · Cited by 1,928 · see citing works
Self-citation3 omega method for specific heat and thermal conductivity measurements
Lu, L., Yi, W., & Zhang, D. L. (2002) · arXiv · doi:10.48550/arxiv.quant-ph/0202038 · Cited by 447 · see citing works
Thermal conductance of metal–diamond interfaces at high pressure
Hohensee, G. T., Wilson, R. B., & Cahill, D. G. (2015) · Nature Communications · doi:10.1038/ncomms7578 · Cited by 197 · see citing works
Self-citationExperimental Techniques for Thin-Film Thermal Conductivity Characterization
Borca-Tasciuc, T., & Chen, G. (2006) · Physics of Solids and Liquids · doi:10.1007/0-387-26017-x_9 · Cited by 23 · see citing works
- Authors
- Cahill, D. G., Fischer, H. E., Klitsner, T., Swartz, E. T., & Pohl, R. O.
- Affiliations
- Cornell University (US)
- Venue
- Journal of Vacuum Science & Technology A: Vacuum, Surfaces, and Films
- Publisher
- American Vacuum Society
- Published
- 1989-05-01
- Volume
- 7
- Issue
- 3
- Pages
- 1259-1266
- ISSN
- 0734-2101 (ISSN-L)
- 1520-8559
- OpenAlex
- W1972680534
- Cited by
- 321
- References
- 0
- Citations by year
- 2026: 5 · 2025: 8 · 2024: 8 · 2023: 11 · 2022: 10 · 2021: 17 · 2020: 15 · 2019: 14 · 2018: 19 · 2017: 13 · 2016: 19 · 2015: 20 · 2014: 11 · 2013: 5 · 2012: 11
- FWCI
- 4.21
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Vacuum Science & Technology A Vacuum Surfaces and Films (publishedVersion)
- Funders
- Semiconductor Research Corporation
- Topics
- Physical Sciences › Materials Science › Materials Chemistry › Thermal properties of materials
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Surface and Thin Film Phenomena
- Physical Sciences › Engineering › Mechanics of Materials › Metal and Thin Film Mechanics
- Keywords
- thermal conductivity, thin films, phonon scattering, phonons, structural perfection
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review