The DOI matches its Crossref record.
Polarization-dependent optical second-harmonic imaging of a rat-tail tendon
Open accessAbstract
Using scanning confocal microscopy, we measure the backscattered second harmonic signal generated by a 100 fs laser in rat-tail tendon collagen. Damage to the sample is avoided by using a continuous scanning technique, rather than measuring the signal at discrete points. The second harmonic signal varies by about a factor of 2 across a single cross section of the rat-tail tendon fascicle. The signal intensity depends both on the collagen organization and the backscattering efficiency. This implies that we cannot use intensity measurements alone to characterize collagen structure. However, we can infer structural information from the polarization dependence of the second harmonic signal. Axial and transverse scans for different linear polarization angles of the input beam show that second harmonic generation (SHG) in the rat-tail tendon depends strongly on the polarization of the input laser beam. We develop an analytical model for the SHG as a function of the polarization angle in the rat-tail tendon. We apply this model in determining the orientation of collagen fibrils in the fascicle and the ratio gamma between the two independent elements of the second-order nonlinear susceptibility tensor. There is a good fit between our model and the measured data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Collagen reorganization at the tumor-stromal interface facilitates local invasion
Provenzano, P. P., Eliceiri, K. W., Campbell, J. M., Inman, D. R., White, J. G., & Keely, P. J. (2006) · BMC Medicine · doi:10.1186/1741-7015-4-38 · Cited by 1,804
Campagnola, P. J., & Loew, L. M. (2003) · Nature Biotechnology · doi:10.1038/nbt894 · Cited by 1,326
Second harmonic generation microscopy for quantitative analysis of collagen fibrillar structure
Chen, X., Nadiarynkh, O., Plotnikov, S., & Campagnola, P. J. (2012) · Nature Protocols · doi:10.1038/nprot.2012.009 · Cited by 985
Interpreting Second-Harmonic Generation Images of Collagen I Fibrils
Williams, R. M., Zipfel, W. R., & Webb, W. W. (2005) · Biophysical Journal · doi:10.1529/biophysj.104.047308 · Cited by 840
Raman Techniques: Fundamentals and Frontiers
Jones, R. R., Hooper, D. C., Zhang, L., Wolverson, D., & Valev, V. K. (2019) · Nanoscale Research Letters · doi:10.1186/s11671-019-3039-2 · Cited by 804
Characterization of the Myosin-Based Source for Second-Harmonic Generation from Muscle Sarcomeres
Plotnikov, S. V., Millard, A. C., Campagnola, P. J., & Mohler, W. A. (2006) · Biophysical Journal · doi:10.1529/biophysj.105.071555 · Cited by 444
Bredfeldt, J. S., Liu, Y., Pehlke, C. A., Conklin, M. W., Szulczewski, J. M., Inman, D. R., Keely, P. J., Nowak, R. D., Mackie, T. R., & Eliceiri, K. W. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.1.016007 · Cited by 412
Second Harmonic Generation Imaging Microscopy: Applications to Diseases Diagnostics
Campagnola, P. (2011) · Analytical Chemistry · doi:10.1021/ac1032325 · Cited by 410
Polarization-Modulated Second Harmonic Generation in Collagen
Stoller, P., Reiser, K. M., Celliers, P. M., & Rubenchik, A. M. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75673-7 · Cited by 400
Self-citationNoninvasive Assessment of Collagen Gel Microstructure and Mechanics Using Multiphoton Microscopy
Raub, C. B., Suresh, V., Krasieva, T., Lyubovitsky, J., Mih, J. D., Putnam, A. J., Tromberg, B. J., & George, S. C. (2007) · Biophysical Journal · doi:10.1529/biophysj.106.097998 · Cited by 374
Ingman, W. V., Wyckoff, J., Gouon‐Evans, V., Condeelis, J., & Pollard, J. W. (2006) · Developmental Dynamics · doi:10.1002/dvdy.20972 · Cited by 273
Second harmonic generation imaging of endogenous structural proteins
Mohler, W., Millard, A. C., & Campagnola, P. J. (2003) · Methods · doi:10.1016/s1046-2023(02)00292-x · Cited by 259
Noninvasive corneal stromal collagen imaging using two-photon-generated second-harmonic signals
Morishige, N., Petroll, M. W., Nishida, T., Kenney, C. M., & Jester, J. V. (2006) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2006.08.027 · Cited by 154
“Particularly strong SHG signals can be obtained from the cornea(14) and used to quantitatively establish collagen fibril orientation with the polarization dependence of the SHG signal.(15) More recent studies use SHG signals to study 3-D collagen organization(16,17) and the effects of laser photoablation.”
MethodTang, P., Kirby, M. A., Le, N., Li, Y., Zeinstra, N., Lu, G. N., Murry, C. E., Zheng, Y., & Wang, R. K. (2021) · Light: Science & Applications · doi:10.1038/s41377-021-00679-3 · Cited by 83
Evaluating Corneal Collagen Organization Using High-Resolution Nonlinear Optical Macroscopy
Jester, J. V., Winkler, M., Jester, B. E., Nien, C., Chai, D., & Brown, D. J. (2010) · Eye & Contact Lens: Science & Clinical Practice · doi:10.1097/icl.0b013e3181ee8992 · Cited by 64
Metadata
- Authors
- Stoller, P., Kim, B.-M., Rubenchik, A. M., Reiser, K. M., & Da Silva, L. B.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2002
- Volume
- 7
- Issue
- 2
- Pages
- 205
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2048593832
- Cited by
- 222
- References
- 0
- FWCI
- 5.11
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.