Properties of erythrocyte light refraction in diabetic patients
Open accessThe DOI matches its Crossref record.
Abstract
Since hyperglycaemia changes the erythrocyte cell membrane fluidity and impairs cell deformity, our goal was to characterize hemoglobin and red blood cell (RBC) light refractive property changes in diabetic patients. Microscopic investigation was carried out on intact and fixed RBCs. To determine the refractive index (RI): smears of peripheral blood were air dried and fixed for 3 min in methanol. Mixtures of polyvinylpyrolidine and buffer of different pH (1:1) were used as embedding media. Intact RBCs were mixed with a buffered embedding medium, placed on a slide and overlaid with a coverslip. Interference microscopy was used for RI measurements at 18 different pH (pH=2-13). The results showed that curves of the RI of diabetic patients and of a control group were of similar configuration, with one branch in the acidic portion of the pH scale, a maximum and two minima in the neutral (middle) portion, and one branch in the alkaline portion. The curves of the individuals from the control group overlapped each other. To the contrary, the curves of the diabetic patients were not uniform in the neutral portion and the alkaline portion. The curves of the diabetic patients in the neutral zone were shifted towards the alkaline end of the pH scale, and the RBC RI curves were lower in comparison to the control curves. The center maximum of the curves of diabetic patients corresponded to pH=6.6 whereas the central maximum of the control group curves was at pH=6.2-6.8. Contrary to in the diabetic group, intact RBC RI curves in the control group revealed only one significantly different minimum at pH of 7.2 in the neutral zone. Using this method it is possible to show phenotypic differences between uniform type intact and fixed cells, erythrocytes of diabetic patients and of healthy donors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Non-invasive glucose monitoring technology in diabetes management: A review
Vashist, S. K. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.03.043 · Cited by 575
Non-Invasive Blood Glucose Monitoring Technology: A Review
Tang, L., Chang, S. J., Chen, C.-J., & Liu, J.-T. (2020) · Sensors · doi:10.3390/s20236925 · Cited by 481
“But the measurements are less accurate on the fingers, and more ideal on the inside of the lips, where blood glucose levels are correlated with optical density [49,50].”
BackgroundTura, A., Maran, A., & Pacini, G. (2007) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2006.10.027 · Cited by 283
“Hyperglycemia can also cause differences in the refractive index of red blood cells, thus leading to different light scattering [16,17].”
BackgroundNon-Invasive Glucose Measurement Technologies: An Update from 1999 to the Dawn of the New Millennium
Khalil, O. S. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2004.6.660 · Cited by 255
Optical clearing of tissues and blood using the immersion method
Tuchin, V. V. (2005) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/38/15/001 · Cited by 232
Metadata
- Authors
- Mazarevica, G., Freivalds, T., & Jurka, A.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2002
- Volume
- 7
- Issue
- 2
- Pages
- 244
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2095771102
- Cited by
- 74
- References
- 0
- FWCI
- 2.87
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Properties of erythrocyte light refraction in diabetic patients. https://app.cochat.ai/papers/10.1117/1.1463043
- The paper
- Mazarevica, G., Freivalds, T., & Jurka, A. (2002). Properties of erythrocyte light refraction in diabetic patients. Journal of Biomedical Optics. https://doi.org/10.1117/1.1463043
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.