Determination of human skin optical properties from spectrophotometric measurements based on optimization by genetic algorithms
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
We present an initial study on applying genetic algorithms (GA) to retrieve human skin optical properties using visual reflectance spectroscopy (VRS). A three-layered skin model consisting of 13 parameters is first used to simulate skin and, through an analytical model based on optical diffusion theory, we study their independent effects on the reflectance spectra. Based on a preliminary analysis, nine skin parameters are chosen to be fitted by GA. The fitting procedure is applied first on simulated reflectance spectra with added white noise, and then on measured spectra from normal and port wine stain (PWS) human skin. A normalized residue of less than 0.005 is achieved for simulated spectra. In the case of measured spectra from human skin, the normalized residue is less than 0.01. Comparisons between applying GA and manual iteration (MI) fitting show that GA performed much better than the MI fitting method and can easily distinguish melanin concentrations for different skin types. Furthermore, the GA approach can lead to a reasonable understanding of the blood volume fraction and other skin properties, provided that the applicability of the diffusion approximation is satisfied.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530
Meglinski, I. V., & Matcher, S. J. (2002) · Physiological Measurement · doi:10.1088/0967-3334/23/4/312 · Cited by 408 · cited 1×
“For example, to determine the impact of the papillary upper dermal thickness (z2), we set all other parameters constant at their average values, and varied z2 by 630%.(3) For all z2 values, we then plotted the reflectance spectra and compared them quantitatively.”
MethodOrigins of Tissue Optical Properties in the UVA, Visible, and NIR Regions
Jacques, S. L. (1996) · Advances in Optical Imaging and Photon Migration · doi:10.1364/aoipm.1996.opc364 · Cited by 247
Cited by
OPTICAL PROPERTIES OF SKIN, SUBCUTANEOUS, AND MUSCLE TISSUES: A REVIEW
BASHKATOV, A. N., GENINA, E. A., & TUCHIN, V. V. (2011) · Journal of Innovative Optical Health Sciences · doi:10.1142/s1793545811001319 · Cited by 761
Optical properties of human skin
Lister, T., Wright, P. A., & Chappell, P. H. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.9.090901 · Cited by 467
Chromophore concentrations, absorption and scattering properties of human skin in-vivo
Tseng, S.-H., Bargo, P., Durkin, A., & Kollias, N. (2009) · Optics Express · doi:10.1364/oe.17.014599 · Cited by 217
Wavelength-dependent penetration depths of ultraviolet radiation in human skin
Meinhardt, M., Krebs, R., Anders, A., Heinrich, U., & Tronnier, H. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2957970 · Cited by 210
In vivo determination of skin near-infrared optical properties using diffuse optical spectroscopy
Tseng, S.-H., Grant, A., & Durkin, A. J. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2829772 · Cited by 139
Metadata
- Authors
- Zhang, R., Verkruysse, W., Choi, B., Viator, J. A., Jung, B., Svaasand, L. O., Aguilar, G., & Nelson, J. S.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2005
- Volume
- 10
- Issue
- 2
- Pages
- 024030
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2059107848
- Cited by
- 95
- References
- 3
- FWCI
- 4.29
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.