Cutaneous melanin exhibiting fluorescence emission under near-infrared light excitation
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Under ultraviolet and visible light excitation, melanin is essentially a nonfluorescent substance. This work reports our study on near-infrared (NIR) fluorescence properties of melanins, and explores potential applications of NIR fluorescence techniques for evaluating skin disorders involving melanin. The NIR fluorescence spectrum is obtained using a fiber optic NIR spectrometer under 785-nm laser excitation. In vitro measurements are performed on synthetic dihydroxyphenylalanine (DOPA) melanin, melanin extracted from Sepia ink sacs, human hair, animal fur, and bird feathers. Paired spectral comparisons of white and black skin appendages show that melanization of hair, fur, or feathers more than doubles the NIR fluorescence. In vivo NIR autofluorescence of normal dorsal and volar forearm skin of 52 volunteers is measured. Dorsal forearm skin, which is darker than volar skin, exhibits significantly greater NIR fluorescence. Patients with vitiligo (n=4), compound nevus (n=3), nevus of Ota (n=1), superficial spreading melanoma (n=3), and postinflammatory hyperpigmentation (n=1) are also evaluated. NIR fluorescence is greater within the lesion than the surrounding normal skin for all these conditions except vitiligo, where the converse was true. The observed melanin NIR fluorescence provides a new approach to in vitro and in vivo melanin detection and quantification that may be particularly useful for evaluating pigmented skin lesions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zonios, G., Bykowski, J., & Kollias, N. (2001) · Journal of Investigative Dermatology · doi:10.1046/j.0022-202x.2001.01577.x · Cited by 477
Ethnic variation in melanin content and composition in photoexposed and photoprotected human skin
Alaluf, S., Atkins, D., Barrett, K., Blount, M., Carter, N., & Heath, A. (2002) · Pigment Cell Research · doi:10.1034/j.1600-0749.2002.1o071.x · Cited by 262 · cited 1×
“It has been shown by observation and histochemical methods that regardless of ethnicity, epidermal melanin content is significantly greater in chronically sun-exposed skin than it is in corresponding sun-protected skin sites up to two-fold .(15,21) In this study, sun-exposed skin dorsal forearm exhibited significantly…”
BackgroundThe impact of epidermal melanin on objective measurements of human skin colour
Alaluf, S., Atkins, D., Barrett, K., Blount, M., Carter, N., & Heath, A. (2002) · Pigment Cell Research · doi:10.1034/j.1600-0749.2002.1o072.x · Cited by 169
Melanin as a confounding factor in near infrared spectroscopy of skin
Matas, A., Sowa, M. G., Taylor, G., & Mantsch, H. H. (2002) · Vibrational Spectroscopy · doi:10.1016/s0924-2031(01)00144-8 · Cited by 50
Cited by
Clinical instrumentation and applications of Raman spectroscopy
Pence, I., & Mahadevan-Jansen, A. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00581g · Cited by 352
Fluorescence lifetime imaging ophthalmoscopy
Dysli, C., Wolf, S., Berezin, M. Y., Sauer, L., Hammer, M., & Zinkernagel, M. S. (2017) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2017.06.005 · Cited by 203
“Under the near-infrared illumination (i.e. 785 nm), melanin is a relatively strong fluorophore (Huang et al., 2006) and a major source of near-infrared fundus autofluorescence (NIR-AF) (Gibbs et al., 2009).”
BackgroundWang, J., Ma, Q., Hu, X.-X., Liu, H., Zheng, W., Chen, X., Yuan, Q., & Tan, W. (2017) · ACS Nano · doi:10.1021/acsnano.7b02643 · Cited by 200
Miura, M., Makita, S., Sugiyama, S., Hong, Y.-J., Yasuno, Y., Elsner, A. E., Tamiya, S., Tsukahara, R., Iwasaki, T., & Goto, H. (2017) · Scientific Reports · doi:10.1038/s41598-017-03529-8 · Cited by 85
Gibbs, D., Cideciyan, A. V., Jacobson, S. G., & Williams, D. S. (2009) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.09-3471 · Cited by 82
Yakimov, B. P., Shirshin, E. A., Schleusener, J., Allenova, A. S., Fadeev, V. V., & Darvin, M. E. (2020) · Scientific Reports · doi:10.1038/s41598-020-71220-6 · Cited by 56
The role of tissue fluorescence in in vivo optical bioimaging
Lifante, J., Shen, Y., Ximendes, E., Martín Rodríguez, E., & Ortgies, D. H. (2020) · Journal of Applied Physics · doi:10.1063/5.0021854 · Cited by 43
Metadata
- Authors
- Huang, Z., Zeng, H., Hamzavi, I., Alajlan, A., Tan, E., McLean, D. I., & Lui, H.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2006
- Volume
- 11
- Issue
- 3
- Pages
- 034010
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2079787990
- Cited by
- 116
- References
- 4
- FWCI
- 1.87
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.