Near-infrared spectroscopy/imaging for monitoring muscle oxygenation and oxidative metabolism in healthy and diseased humans
Open accessThe DOI matches its Crossref record; 148 of the 230 references it cites were found in a registry or an index, and 81 are not checked yet.
Abstract
Near-infrared spectroscopy (NIRS) was initiated in 1977 by Jobsis as a simple, noninvasive method for measuring the presence of oxygen in muscle and other tissues in vivo. This review honoring Jobsis highlights the progress that has been made in developing and adapting NIRS and NIR imaging (NIRI) technologies for evaluating skeletal muscle O2 dynamics and oxidative energy metabolism. Development of NIRS/NIRI technologies has included novel approaches to quantification of the signal, as well as the addition of multiple source detector pairs for imaging. Adaptation of NIRS technology has focused on the validity and reliability of NIRS measurements. NIRS measurements have been extended to resting, ischemic, localized exercise, and whole body exercise conditions. In addition, NIRS technology has been applied to the study of a number of chronic health conditions, including patients with chronic heart failure, peripheral vascular disease, chronic obstructive pulmonary disease, varying muscle diseases, spinal cord injury, and renal failure. As NIRS technology continues to evolve, the study of skeletal muscle function with NIRS first illuminated by Jobsis continues to be bright.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“When debating a specific gold standard to which NIRS-derived SmO2 should be compared, an obvious lack of authority exists as the term is not mentioned in reviews,6,20,21 with appropriate hesitation.”
From Near-infrared spectroscopy-derived muscle oxygen saturation on a 0% to 100% scale: reliability and validity of the Moxy Monitor (2019) · cites this paper as [20]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Items 201–230 of 230
Hosoi, Y., Yasuhara, H., Shigematsu, H., Aramoto, H., Komiyama, T., & Muto, T. (1997) · Journal of Vascular Surgery · doi:10.1016/s0741-5214(97)70147-2 · Cited by 23
Moalla, W., Dupont, G., Costes, F., Gauthier, R., Maingourd, Y., & Ahmaidi, S. (2006) · International Journal of Sports Medicine · doi:10.1055/s-2006-923787 · Cited by 22
Nioka, S., Wang, D.-J., Im, J., Hamaoka, T., Wang, Z., LEIGH, J. S. J., & Chance, B. (2006) · Advances in experimental medicine and biology · doi:10.1007/0-387-29540-2_36 · Cited by 21 · cited 5×
“2 A simulation experiment based on combined measurements of 1 H-MRS and NIRS concluded that the overall NIR signal would be greater than (cid:5) 50% Hb. 52 In contrast, Tran et al. reported a greater contribution of Mb signal than Hb to the overall NIR signals in a study using 1 H-MRS .”
BackgroundInfluentialSelf-citationKell, R. T., & BHAMBHANI, Y. N. (2003) · European Journal of Applied Physiology · doi:10.1007/s00421-002-0776-0 · Cited by 21 · cited 1×
“to muscle oxygenation, there are several studies that have documented the changes in tHb during exercise.(98,99) While”
BackgroundKuge, N., Suzuki, T., & Isoyama, S. (2005) · The Tohoku Journal of Experimental Medicine · doi:10.1620/tjem.207.303 · Cited by 20 · cited 1×
“vasodilator responses to 3-min arterial occlusion were measured by NIRS in patients receiving hemodialysis.(171) Vasodilator responses estimated by the ratio of the maximum value”
MethodBringard, A., & Perrey, S. (2004) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2004.00554.x · Cited by 19
Inuzuka, K., Unno, N., Mitsuoka, H., Yamamoto, N., Ishimaru, K., Sagara, D., Suzuki, M., & Konno, H. (2005) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2005.09.019 · Cited by 19
Yamaki, T., NOZAKI, M., Sakurai, H., Takeuchi, M., Soejima, K., & KONO, T. (2006) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2006.01859.x · Cited by 17
Muscle Oxygen Desaturation is Related to Whole Body V˙O2 During Cross-Country Ski Skating
lm, J., Nioka, S., Chance, B., & Rundell, K. (2001) · International Journal of Sports Medicine · doi:10.1055/s-2001-15653 · Cited by 17 · cited 1×
“NIRS has also been used for evaluating acute and chronic training effects of exercise on muscle oxygenation for athletes such as endurance cyclists, sprinters,(187) endurance runners,(152,187) swimmers,(188) triathletes,(25,152,183) soccer players,(189) resistance-trained athletes,(190) skaters,(191) and crosscountry…”
BackgroundSelf-citationHomma, T., Hamaoka, T., Sako, T., Murakami, M., Esaki, K., Kime, R., & Katsumura, T. (2005) · Dynamic Medicine · doi:10.1186/1476-5918-4-2 · Cited by 16
Self-citationMeasurement of critical lower limb tissue hypoxia by coupling chemical and optical techniques
Salman, M., Glantzounis, G. K., Yang, W., Myint, F., Hamilton, G., & Seifalian, A. M. (2005) · Clinical Science · doi:10.1042/cs20040175 · Cited by 16
Evaluation of tissue saturation as a noninvasive measure of mixed venous saturation in children
Levy, R. J., Stern, W., Minger, K. I., Montenegro, L. M., Ravishankar, C., Rome, J. J., Nicolson, S. C., & Jobes, D. R. (2005) · Pediatric Critical Care Medicine · doi:10.1097/01.pcc.0000185488.44719.b0 · Cited by 16
Niwayama, M., Hamaoka, T., Lin, L., Shao, J., Kudo, N., Katoh, C., & Yamamoto, K. (2000) · SPIE Proceedings · doi:10.1117/12.384911 · Cited by 16 · cited 1×
“detector separation being 15 to 40 mm.(39,42,43) The curve was obtained from the results of both Monte Carlo simulation and in-vivo experiments.”
MethodSelf-citationIntramyocellular lipid, adiposity, and muscle oxygen supply in prepubertal type 1 diabetes
Ling, A. H., Donaghue, K. C., Howard, N. J., Arrowsmith, F., Ward, J. A., Baur, L. A., & Thompson, C. H. (2003) · Pediatric Diabetes · doi:10.1034/j.1399-5448.2003.00021.x · Cited by 15
Murakami, M., Katsumura, T., Hamaoka, T., Osada, T., Sako, T., Higuchi, H., Esaki, K., Kime, R., & Shimomitsu, T. (2000) · Journal of Biomedical Optics · doi:10.1117/1.1289143 · Cited by 15
Self-citationEffects of glutamine and hyperoxia on pulmonary oxygen uptake and muscle deoxygenation kinetics
Marwood, S., & Bowtell, J. L. (2006) · European Journal of Applied Physiology · doi:10.1007/s00421-006-0324-4 · Cited by 14 · cited 1×
“cently, there have been several studies to evaluate oxygen uptake kinetics during exercise using NIRS indicators such as HHb delay, HHb mean response time, and HHb time constant at the onset of exercise.(35,149,150,156)”
BackgroundKimura, N., Hamaoka, T., Kurosawa, Y., & Katsumura, T. (2006) · The Tohoku Journal of Experimental Medicine · doi:10.1620/tjem.208.307 · Cited by 13
Self-citationOkuma, H., Kurita, D., Ohnuki, T., Haida, M., & Shinohara, Y. (2006) · International Journal of Clinical Practice · doi:10.1111/j.1742-1241.2006.00968.x · Cited by 13
Nishiyasu, T., Maekawa, T., Sone, R., Tan, N., & Kondo, N. (2005) · Experimental Physiology · doi:10.1113/expphysiol.2005.032052 · Cited by 11
Mizuno, M., Tokizawa, K., & Muraoka, I. (2006) · European Journal of Applied Physiology · doi:10.1007/s00421-005-0110-8 · Cited by 9
Functional imaging of muscle oxygenation using a 200-channel cw NIRS system:
Yamamoto, K., Niwayama, M., Kohata, D., Kudo, N., Hamaoka, T., Kime, R., & Katsumura, T. (2001) · SPIE Proceedings · doi:10.1117/12.434486 · Cited by 8
Self-citationNiwayama, M., Kohata, D., Shao, J., Kudo, N., Hamaoka, T., Katsumura, T., & Yamamoto, K. (2000) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.390566 · Cited by 8 · cited 3×
“detector separation being 15 to 40 mm.(39,42,43) The curve was obtained from the results of both Monte Carlo simulation and in-vivo experiments.”
BackgroundMethodSelf-citationQuantitative Evaluation of Oxygenation and Metabolism in the Human Skeletal Muscle
Hamaoka, T., Osada, T., Murase, N., Sako, T., Higuchi, H., Kurosawa, Y., Miwa, M., Katsumura, T., & Chance, B. (2003) · Optical Review · doi:10.1007/s10043-003-0493-x · Cited by 7
Self-citationPhosphomonoesters Predict Early Mortality in Porcine Hemorrhagic Shock
Taylor, J. H., Beilman, G. J., Conroy, M. J., Mulier, K. E., & Hammer, B. E. (2004) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/01.ta.0000111750.67500.13 · Cited by 6
Mizuno, M., Hamaoka, T., Osada, T., Shimomitsu, T., Katsumura, T., & Quistorff, B. (1999) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199905001-01342 · Cited by 5
Self-citationQuantification of oxidative metabolism in masseter muscle of denture wearers
Fujii, A., Shinogaya, T., Toda, S., & Hayakawa, I. (2005) · Clinical Oral Investigations · doi:10.1007/s00784-004-0300-5 · Cited by 3
Spectrophotometric Studies on Intact Muscle
Jöbsis, F. F. (1963) · The Journal of General Physiology · doi:10.1085/jgp.46.5.929
Wolf, M., Wolf, U., Choi, J. H., Gupta, R., Safonova, L. P., Paunescu, L. A., Michalos, A., & Gratton, E. (2003) · Advances in Experimental Medicine and Biology · doi:10.1007/978-1-4615-0205-0_32
Yang, Y., Soyemi, O. O., Landry, M. R., & Soller, B. R. (2005) · SPIE Proceedings · doi:10.1117/12.585256 · cited 1×
“41 The study suggested that subject-to-subject variation in the fat optical coefficients and thickness can be ignored if the fat thickness is less than 5 mm when the source-detector separation is 40 mm .”
Background(1997) · Muscle & Nerve
Research works printed but not linked: 9
- V. Quaresima, R. Lepanto, and M. Ferrari, "The use of near infrared spectroscopy in sports medicine," J. Sports Med. Phys. Fitness 43, 1-13 ͑2003͒.
- K. K. McCully and T. Hamaoka, "Near-infrared spectroscopy: what can it tell us about oxygen saturation in skeletal muscle?," Exerc Sport Sci. Rev. 28, 123-127 ͑2000͒.
- M. Niwayama, K. Yamamoto, D. Kohata, K. Hirai, N. Kudo, T. Hamaoka, R. Kime, and T. Katsumura, "A 200-channel imaging sys- tem of muscle oxygenation using CW near-infrared spectroscopy," IEICE Trans. Inf. Syst. E85-D, 115-123 ͑2002͒.
- B. Chance, D. J. Wang, S. Nioka, Z. Wang, E. A. Noyszewski, T. Hamaoka, and J. S. Leigh, Jr., "Myoglobin and hemoglobin deoxy- genation during muscle exercise in dogs," Specialty Conf. Am. Col- lege Sports Med. Regulation Oxidative Metab. Blood Flow Skele. Muscle abstract, p. 20 ͑1995͒.
- O. Piazza, G. Zito, A. Valente, and R. Tufano, "Effects of dopamine infusion on forearm blood flow in critical patients," Med. Sci. Monit 12, CR90-93 ͑2006͒.
- Buono, 2005, Eur. J. Vasc. Surg., 55, 241
- Komiyama, 1996, Int. Angiol, 15, 215
- Belardinelli, 1995, G. Ital. Cardiol., 25, 715
- Tateishi, 2005, Osaka City Med. J., 51, 65
Cited by
Muscle fatigue: what, why and how it influences muscle function
Enoka, R. M., & Duchateau, J. (2008) · The Journal of Physiology · doi:10.1113/jphysiol.2007.139477 · Cited by 1,672
Principles, Techniques, and Limitations of Near Infrared Spectroscopy
Ferrari, M., Mottola, L., & Quaresima, V. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-031 · Cited by 997
Self-citationScholkmann, F., Spichtig, S., Muehlemann, T., & Wolf, M. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/5/004 · Cited by 683
“…© 2010 Institute of Physics and Engineering in Medicine Printed in the UK 649 applications in medicine and neuroscience expanded (Boushel et al 2001, Ferrari et al 2004, Wolf et al 2007, Hoshi 2007, Hamaoka et al 2007, Muehlemann et al 2008, Gibson and Dehghani 2009).”
BackgroundProgress of near-infrared spectroscopy and topography for brain and muscle clinical applications
Ferrari, M. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2804899 · Cited by 600
Self-citationMancini, D. M., Katz, S. D., Lang, C. C., LaManca, J., Hudaihed, A., & Androne, A.-S. (2003) · Circulation · doi:10.1161/01.cir.0000044914.42696.6a · Cited by 542
Metadata
- Authors
- Hamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B.
- Affiliations
- Tokyo Medical College
- University of Georgia (US)
- University of L'Aquila (IT)
- Hokkaido University (JP)
- University of Pennsylvania (US)
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2007-11-01
- Volume
- 12
- Issue
- 06
- Pages
- 1-16
- ISSN
- 1083-3668 (ISSN-L)
- 1560-2281
- OpenAlex
- W4297832436
- Semantic Scholar
- 2bda5bdb3ef3a60cc093249ee0e38d98c8f71ea5
- Cited by
- 329
- References
- 222
- Citations by year
- 2026: 15 · 2025: 6 · 2024: 14 · 2023: 12 · 2022: 18 · 2021: 19 · 2020: 19 · 2019: 25 · 2018: 17 · 2017: 21 · 2016: 18 · 2015: 20 · 2014: 13 · 2013: 17 · 2012: 26
- FWCI
- 1.82
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Journal of Biomedical Optics (publishedVersion)
- Archivio Istituzionale della Ricerca - Università degli Studi dell Aquila (submittedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Infrared Thermography in Medicine
- Keywords
- near-infrared spectroscopy, near-infrared imaging, muscle oxygenation, skeletal muscle oxidative metabolism, muscle oxygen dynamics, signal quantification, physical activity, ischemia, chronic heart failure, peripheral vascular disease, chronic obstructive pulmonary disease, myopathy, spinal cord injury, renal failure
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.