Spectral imaging facilitates visualization and measurements of unstable and abnormal microvascular oxygen transport in tumors
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Abnormal microvasculature contributes to the pathophysiologic microenvironment of tumors. Understanding microvascular tumor oxygen transport is necessary to comprehend the factors that influence tumor biology, physiology, and therapy. Previously, we described an in vivo spectral imaging microscopy system for measurements of microvessel hemoglobin saturation (HbSat). We measure temporal fluctuations and spatial gradients in tumor microvessel oxygenation and identify instances of anastomoses between vessels with significantly different oxygenations. Slow periodic fluctuations in HbSat <0.2 cycles per minute were observed. These measurements are consistent with microelectrode measurements of fluctuating tumor oxygenation. Gradients in HbSat along individual tumor microvessels were measured that were larger in magnitude than normal tissue microvessels. Images were captured of anastomoses of tumor microvessels with diameters 20%). Shunting of inspired oxygen, presumably due to arteriovenous anastomoses, from tumor feeding arterioles to adjacent venules was imaged. This effect was confined to a region around the tumor and was not observed in nearby normal microvessels. Imaging measurements of tumor microvessel oxygen transport may offer insight to current questions regarding oxygen-related tumor biology and treatment responses, and spectral imaging may be a useful research tool in this regard.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tumor Hypoxia: Definitions and Current Clinical, Biologic, and Molecular Aspects
Hockel, M., & Vaupel, P. (2001) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/93.4.266 · Cited by 2,662
Normalizing tumor vasculature with anti-angiogenic therapy: A new paradigm for combination therapy
Jain, R. K. (2001) · Nature Medicine · doi:10.1038/nm0901-987 · Cited by 2,184
Tumour hypoxia, chemotherapeutic resistance and hypoxia-related therapies
Shannon, A. M., Bouchier-Hayes, D. J., Condron, C. M., & Toomey, D. (2003) · Cancer Treatment Reviews · doi:10.1016/s0305-7372(03)00003-3 · Cited by 559
Martinive, P., Defresne, F., Bouzin, C., Saliez, J., Lair, F., Grégoire, V., Michiels, C., Dessy, C., & Feron, O. (2006) · Cancer Research · doi:10.1158/0008-5472.can-06-2056 · Cited by 190
Cited by
Hypoxia and the extracellular matrix: drivers of tumour metastasis
Gilkes, D. M., Semenza, G. L., & Wirtz, D. (2014) · Nature Reviews Cancer · doi:10.1038/nrc3726 · Cited by 1,520
Cycling hypoxia and free radicals regulate angiogenesis and radiotherapy response
Dewhirst, M. W., Cao, Y., & Moeller, B. (2008) · Nature Reviews Cancer · doi:10.1038/nrc2397 · Cited by 1,022
Self-citationTransport of drugs from blood vessels to tumour tissue
Dewhirst, M. W., & Secomb, T. W. (2017) · Nature Reviews Cancer · doi:10.1038/nrc.2017.93 · Cited by 749
Self-citationPark, S. O., Wankhede, M., Lee, Y. J., Choi, E.-J., Fliess, N., Choe, S.-W., Oh, S.-H., Walter, G., Raizada, M. K., Sorg, B. S., et al. (2009) · Journal of Clinical Investigation · doi:10.1172/jci39482 · Cited by 300
Self-citation
Metadata
- Authors
- Sorg, B. S., Hardee, M. E., Agarwal, N., Moeller, B. J., & Dewhirst, M. W.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2008
- Volume
- 13
- Issue
- 1
- Pages
- 014026
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2011649403
- Cited by
- 75
- References
- 4
- FWCI
- 5.02
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Spectral imaging facilitates visualization and measurements of unstable and abnormal microvascular oxygen transport in tumors. https://app.cochat.ai/papers/10.1117/1.2837439
- The paper
- Sorg, B. S., Hardee, M. E., Agarwal, N., Moeller, B. J., & Dewhirst, M. W. (2008). Spectral imaging facilitates visualization and measurements of unstable and abnormal microvascular oxygen transport in tumors. Journal of Biomedical Optics. https://doi.org/10.1117/1.2837439
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.