Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 316

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Raman microscopy for dynamic molecular imaging of living cells

Open access
Hamada, Keisaku, Fujita, Katsumasa, Smith, Nicholas I., Kobayashi, Minoru, Inouye, Yasushi, Kawata, Satoshi · 2008 · Journal of Biomedical Optics

Abstract

We demonstrate dynamic imaging of molecular distribution in unstained living cells using Raman scattering. By combining slit-scanning detection and optimizing the excitation wavelength, we imaged the dynamic molecular distributions of cytochrome c, protein beta sheets, and lipids in unstained HeLa cells with a temporal resolution of 3 minutes. We found that 532-nm excitation can be used to generate strong Raman scattering signals and to suppress autofluorescence that typically obscures Raman signals. With this technique, we reveal time-resolved distributions of cytochrome c and other biomolecules in living cells in the process of cytokinesis without the need for fluorescent labels or markers.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1117/1.2952192

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 14 references

Cited by

Metadata

Authors
Hamada, K., Fujita, K., Smith, N. I., Kobayashi, M., Inouye, Y., & Kawata, S.
Venue
Journal of Biomedical Optics
Published
2008-07-01
Volume
13
Issue
04
Pages
1
ISSN
1083-3668 (ISSN-L)
OpenAlex
W2050103929
Cited by
316
References
14
FWCI
7.79
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.