The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Current status of midinfrared quantum and interband cascade lasers for clinical breath analysis
Abstract
State-of-the-art quantum- and interband-cascade-based chemical sensors may be effective new tools for the identification and quantification of trace gases in human breath for clinical uses. Increased or decreased concentrations of these molecules are associated with the pathogenesis of a large number of diseases. Current technologies enable breath analyses to be performed on a single breath and the results are available in real time. Critical parameters including sensor sensitivity, selectivity, real-time monitoring capability, robustness, cost, size, and weight determine the progress made toward the development and availability of commercial diagnostic material.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200406-710st · Cited by 3,203
Endogenous nitric oxide is present in the exhaled air of rabbits, guinea pigs and humans
Gustafsson, L. E., Leone, A. M., Persson, M. G., Wiklund, N. P., & Moncada, S. (1991) · Biochemical and Biophysical Research Communications · doi:10.1016/0006-291x(91)91268-h · Cited by 964
Quantitative analysis of ammonia on the breath of patients in end-stage renal failure
Davies, S., Spanel, P., & Smith, D. (1997) · Kidney International · doi:10.1038/ki.1997.324 · Cited by 406
Cited by
Amann, A., Costello, B. D. L., Miekisch, W., Schubert, J., Buszewski, B., Pleil, J., Ratcliffe, N., & Risby, T. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/3/034001 · Cited by 804
Review—Non-Invasive Monitoring of Human Health by Exhaled Breath Analysis: A Comprehensive Review
Das, S., & Pal, M. (2020) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/ab67a6 · Cited by 466
Is breath acetone a biomarker of diabetes? A historical review on breath acetone measurements
Wang, Z., & Wang, C. (2013) · Journal of Breath Research · doi:10.1088/1752-7155/7/3/037109 · Cited by 309
Breath Analysis as a Potential and Non-Invasive Frontier in Disease Diagnosis: An Overview
Pereira, J., Porto-Figueira, P., Cavaco, C., Taunk, K., Rapole, S., Dhakne, R., Nagarajaram, H., & Câmara, J. (2015) · Metabolites · doi:10.3390/metabo5010003 · Cited by 301
Tunable diode laser spectroscopy as a technique for combustion diagnostics
Bolshov, M. A., Kuritsyn, Y. A., & Romanovskii, Y. V. (2015) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/j.sab.2015.01.010 · Cited by 255
Metadata
- Authors
- Tittel, F. K.
- Venue
- Optical Engineering
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2010-11-01
- Volume
- 49
- Issue
- 11
- Pages
- 111123
- ISSN
- 0091-3286 (ISSN-L)
- OpenAlex
- W2089028276
- Cited by
- 181
- References
- 3
- FWCI
- 6.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.