Regional tissue oxygen saturation: comparability and reproducibility of different devices
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
UNLABELLED: Comparability and reproducibility of different near-infrared spectroscopy devices measuring regional tissue oxygen saturation remain poor. Aim of the present study was to compare values and reproducibility of cerebral∕peripheral "tissue-oxygenation-index" (TOI; NIRO 300, Hamamatsu(®), Japan) with cerebral∕peripheral "regional-oxygen-saturation" (rSO; INVOS5100, Somanetics(®), USA), and to analyze the influence of quality criteria. METHODS: cTOI and crSO2 were measured on the left forehead, pTOI and prSO2 were measured on the left calf. To analyse reproducibility, optodes were reapplied five times. A quality criterion was introduced for cTOI, crSO2 and prSO2. For pTOI quality criteria were introduced in combination with a venous occlusion technique. RESULTS: Cerebral measurements were performed in 37 neonates. cTOI (72.7+∕-6.2%) was lower than crSO2 (83.3+∕-5.8%) (p < 0.001). The mean difference between cTOI and crSO2 was 10%. Mean standard deviations of cTOI and crSO2 were similar (cTOI: 4.9+∕-3.6; crSO2: 4.5+∕-2.6). Peripheral measurements were performed in 39 neonates. pTOI (66.0+∕-7.9%) was lower than prSO2 (82.0+∕-7.0%)(p < 0.001). The mean difference between pTOI and prSO2 was 15%. Mean standard deviations of pTOI (3.7+∕-2.6%) were lower than of prSO2 (5.0+∕-3.0%) (p = 0.047). CONCLUSION: TOI values were significantly lower than rSO2 values, in cerebral and peripheral measurements. Reproducibility was higher for pTOI than for prSO2.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
Thavasothy, M., Broadhead, M., Elwell, C., Peters, M., & Smith, M. (2002) · Anaesthesia · doi:10.1046/j.1365-2044.2002.02826.x · Cited by 165
Cited by
NIRS in clinical neurology — a ‘promising’ tool?
Obrig, H. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.03.045 · Cited by 227
“…over the less reliable estimation of redox-changes in cytochromeoxidase (cyt-ox) (Tisdall et al., 2007) to a number of derivations yielding oxygenation indices such as regional oxygen saturation (rSaO2) or the tissue oxygenation index (TOI) (Al-Rawi and Kirkpatrick, 2006; Pocivalnik et al., 2011).”
BackgroundMethodInfluentialAlderliesten, T., Dix, L., Baerts, W., Caicedo, A., van Huffel, S., Naulaers, G., Groenendaal, F., van Bel, F., & Lemmers, P. (2016) · Pediatric Research · doi:10.1038/pr.2015.186 · Cited by 199
Pichler, G., Binder, C., Avian, A., Beckenbach, E., Schmölzer, G. M., & Urlesberger, B. (2013) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2013.07.007 · Cited by 194
Self-citationComparison of tissue oximeters on a liquid phantom with adjustable optical properties
Kleiser, S., Nasseri, N., Andresen, B., Greisen, G., & Wolf, M. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.002973 · Cited by 103
Hyttel-Sorensen, S., Sorensen, L. C., Riera, J., & Greisen, G. (2011) · Biomedical Optics Express · doi:10.1364/boe.2.003047 · Cited by 92
Metadata
- Authors
- Pocivalnik, M., Pichler, G., Zotter, H., Tax, N., Müller, W., & Urlesberger, B.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2011
- Volume
- 16
- Issue
- 5
- Pages
- 057004
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2119710800
- Cited by
- 62
- References
- 2
- FWCI
- 4.83
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.