Improved tumor contrast achieved by single time point dual-reporter fluorescence imaging
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
In this study, we demonstrate a method to quantify biomarker expression that uses an exogenous dual-reporter imaging approach to improve tumor signal detection. The uptake of two fluorophores, one nonspecific and one targeted to the epidermal growth factor receptor (EGFR), were imaged at 1 h in three types of xenograft tumors spanning a range of EGFR expression levels (n=6 in each group). Using this dual-reporter imaging methodology, tumor contrast-to-noise ratio was amplified by >6 times at 1 h postinjection and >2 times at 24 h. Furthermore, by as early as 20 min postinjection, the dual-reporter imaging signal in the tumor correlated significantly with a validated marker of receptor density (P<0.05, r=0.93). Dual-reporter imaging can improve sensitivity and specificity over conventional fluorescence imaging in applications such as fluorescence-guided surgery and directly approximates the receptor status of the tumor, a measure that could be used to inform choices of biological therapies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stummer, W., Pichlmeier, U., Meinel, T., Wiestler, O. D., Zanella, F., & Reulen, H.-J. (2006) · The Lancet Oncology · doi:10.1016/s1470-2045(06)70665-9 · Cited by 3,423
Drug penetration in solid tumours
Minchinton, A. I., & Tannock, I. F. (2006) · Nature reviews. Cancer · doi:10.1038/nrc1893 · Cited by 2,805 · cited 1×
“The problem with this approach is that the uptake of a targeted reporter in a specific region of interest is not just governed by that region’s targeted receptor expression; other physiological factors play roles as well, such as blood flow, vessel permeability, cellular internalization, interstitial pressure, and oth…”
BackgroundConsensus Nomenclature for in vivo Imaging of Reversibly Binding Radioligands
Innis, R. B., Cunningham, V. J., Delforge, J., Fujita, M., Gjedde, A., Gunn, R. N., Holden, J., Houle, S., Huang, S.-C., Ichise, M., et al. (2007) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/sj.jcbfm.9600493 · Cited by 1,955 · cited 1×
“where k3∕k4 is, by definition, the binding potential, BP, which is equal to the product of the affinity of the targeted reporter for its receptor and the receptor density.(27) Because the ratio on the lefthand side of Eq.”
Background
Cited by
Wang, Y. W., Kang, S., Khan, A., Bao, P. Q., & Liu, J. T. C. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.003714 · Cited by 110
Wang, Y. “., Reder, N. P., Kang, S., Glaser, A. K., Yang, Q., Wall, M. A., Javid, S. H., Dintzis, S. M., & Liu, J. T. C. (2017) · Cancer Research · doi:10.1158/0008-5472.can-17-0709 · Cited by 104
Rapid ratiometric biomarker detection with topically applied SERS nanoparticles
Wang, Y. "., Khan, A., Som, M., Wang, D., Chen, Y., Leigh, S. Y., Meza, D., McVeigh, P. Z., Wilson, B. C., & Liu, J. T. C. (2014) · TECHNOLOGY · doi:10.1142/s2339547814500125 · Cited by 74
McMahon, N. P., Solanki, A., Wang, L. G., Montaño, A. R., Jones, J. A., Samkoe, K. S., Tichauer, K. M., & Gibbs, S. L. (2021) · Molecular Imaging and Biology · doi:10.1007/s11307-021-01589-x · Cited by 8
Self-citation
Metadata
- Authors
- Tichauer, K. M., Samkoe, K. S., Sexton, K. J., Gunn, J. R., Hasan, T., & Pogue, B. W.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2012
- Volume
- 17
- Issue
- 6
- Pages
- 066001
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2108413422
- Cited by
- 68
- References
- 3
- FWCI
- 4.23
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.