Filter-based method for background removal in high-sensitivity wide-field-surface-enhanced Raman scattering imaging in vivo
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
As molecular imaging moves towards lower detection limits, the elimination of endogenous background signals becomes imperative. We present a facile background-suppression technique that specifically segregates the signal from surface-enhanced Raman scattering (SERS)-active nanoparticles (NPs) from the tissue autofluorescence background in vivo. SERS NPs have extremely narrow spectral peaks that do not overlap significantly with endogenous Raman signals. This can be exploited, using specific narrow-band filters, to image picomolar (pM) concentrations of NPs against a broad tissue autofluorescence background in wide-field mode, with short integration times that compare favorably with point-by-point mapping typically used in SERS imaging. This advance will facilitate the potential applications of SERS NPs as contrast agents in wide-field multiplexed biomarker-targeted imaging in vivo.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zavaleta, C. L., Smith, B. R., Walton, I., Doering, W., Davis, G., Shojaei, B., Natan, M. J., & Gambhir, S. S. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0813327106 · Cited by 714
Cited by
A Raman-based endoscopic strategy for multiplexed molecular imaging
Zavaleta, C. L., Garai, E., Liu, J. T. C., Sensarn, S., Mandella, M. J., Van de Sompel, D., Friedland, S., Van Dam, J., Contag, C. H., & Gambhir, S. S. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1211309110 · Cited by 238
A small animal Raman instrument for rapid, wide-area, spectroscopic imaging
Bohndiek, S. E., Wagadarikar, A., Zavaleta, C. L., Van de Sompel, D., Garai, E., Jokerst, J. V., Yazdanfar, S., & Gambhir, S. S. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1301379110 · Cited by 133
“In addition to point scanning, it also is possible to perform direct, or “global,” Raman imaging (10) for in vivo applications (12, 13), in which a wide area (up to 2 cm(2)) is illuminated and all spatial points of the image are collected simultaneously on a 2D CCD at a single detection wavelength.”
BackgroundWang, Y. W., Kang, S., Khan, A., Bao, P. Q., & Liu, J. T. C. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.003714 · Cited by 110
Rapid ratiometric biomarker detection with topically applied SERS nanoparticles
Wang, Y. "., Khan, A., Som, M., Wang, D., Chen, Y., Leigh, S. Y., Meza, D., McVeigh, P. Z., Wilson, B. C., & Liu, J. T. C. (2014) · TECHNOLOGY · doi:10.1142/s2339547814500125 · Cited by 74
Self-citationLi, X., Zhou, R., Xu, Y., Wei, X., & He, Y. (2017) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2016.1226183 · Cited by 13
“(40) used surfaceenhanced Raman scattering (SERS)active nanoparticles (NPs) which have extremely”
Background
Metadata
- Authors
- Mallia, R. J., McVeigh, P. Z., Veilleux, I., & Wilson, B. C.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2012-07-13
- Volume
- 17
- Issue
- 7
- Pages
- 0760171
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2056220298
- Cited by
- 25
- References
- 1
- FWCI
- 1.46
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Filter-based method for background removal in high-sensitivity wide-field-surface-enhanced Raman scattering imaging in vivo. https://app.cochat.ai/papers/10.1117/1.jbo.17.7.076017
- The paper
- Mallia, R. J., McVeigh, P. Z., Veilleux, I., & Wilson, B. C. (2012). Filter-based method for background removal in high-sensitivity wide-field-surface-enhanced Raman scattering imaging in vivo. Journal of Biomedical Optics. https://doi.org/10.1117/1.jbo.17.7.076017
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.