Mueller matrix polarimetry for differentiating characteristic features of cancerous tissues
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Polarization measurements allow one to enhance the imaging contrast of superficial tissues and obtain new polarization sensitive parameters for better descriptions of the micro- and macro- structural and optical properties of complex tissues. Since the majority of cancers originate in the epithelial layer, probing the morphological and pathological changes in the superficial tissues using an expended parameter set with improved contrast will assist in early clinical detection of cancers. We carry out Mueller matrix imaging on different cancerous tissues to look for cancer specific features. Using proper scattering models and Monte Carlo simulations, we examine the relationship between the microstructures of the samples, which are represented by the parameters of the scattering model and the characteristic features of the Mueller matrix. This study gives new clues on the contrast mechanisms of polarization sensitive measurements for different cancers and may provide new diagnostic techniques for clinical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Interpretation of Mueller matrices based on polar decomposition
Lu, S.-Y., & Chipman, R. A. (1996) · Journal of the Optical Society of America A · doi:10.1364/josaa.13.001106 · Cited by 1,409 · cited 1×
“, the depolarization power Δ, the retardance R (including the linear retardance δ and circle retardance Ψ), and the diattenuation D.(15) For the MMT, we use a set of parameters that are explicitly related to different characteristic microstructures of the anisotropic tissue samples, such as the density of subwavelengt…”
MethodLasers in Surgery and Medicine
(2006) · Lasers in Surgery and Medicine · doi:10.1002/(issn)1096-9101 · Cited by 1,088
Detection of preinvasive cancer cells
Backman, V., Wallace, M. B., Perelman, L. T., Arendt, J. T., Gurjar, R., Müller, M. G., Zhang, Q., Zonios, G., Kline, E., McGillican, T., et al. (2000) · Nature · doi:10.1038/35017638 · Cited by 621 · cited 1×
“For cancerous tissues, the well-known pathological features include increases in the cell density and number density of the mitochondria, both of which lead to increases in the number of “small” scatterers in the cancerous region.(1) We also applied polarization measurements to the nonstained”
BackgroundImaging skin pathology with polarized light
Jacques, S. L., Ramella-Roman, J. C., & Lee, K. (2002) · Journal of Biomedical Optics · doi:10.1117/1.1484498 · Cited by 582
Imaging superficial tissues with polarized light
Jacques, S. L., Roman, J. R., & Lee, K. (2000) · Lasers in Surgery and Medicine · doi:10.1002/(sici)1096-9101(2000)26:2<119::aid-lsm3>3.0.co;2-y · Cited by 366
Ex-vivo characterization of human colon cancer by Mueller polarimetric imaging
Pierangelo, A., Benali, A., Antonelli, M.-R., Novikova, T., Validire, P., Gayet, B., & De Martino, A. (2011) · Optics Express · doi:10.1364/oe.19.001582 · Cited by 294
Optical Polarization in Biomedical Applications
Tuchin, V. V., Novikova, T., Wang, L. V., Zimnyakov, D. A., Ma, H., Васильевна, А. М., & Wan, J. (2006) · Springer series in biophysics · doi:10.1007/978-3-032-16073-7 · Cited by 289
Self-citationPolarimetric imaging of uterine cervix: a case study
Pierangelo, A., Nazac, A., Benali, A., Validire, P., Cohen, H., Novikova, T., Ibrahim, B. H., Manhas, S., Fallet, C., Antonelli, M.-R., et al. (2013) · Optics Express · doi:10.1364/oe.21.014120 · Cited by 255
Multispectral scanning during endoscopy guides biopsy of dysplasia in Barrett's esophagus
Qiu, L., Pleskow, D. K., Chuttani, R., Vitkin, E., Leyden, J., Ozden, N., Itani, S., Guo, L., Sacks, A., Goldsmith, J. D., et al. (2010) · Nature Medicine · doi:10.1038/nm.2138 · Cited by 165
He, H., Zeng, N., Du, E., Guo, Y., Li, D., Liao, R., & Ma, H. (2013) · Photonics and Lasers in Medicine · doi:10.1515/plm-2012-0052 · Cited by 156 · cited 3×
“subwavelength scatterers or the orientation and alignment of the fibers.(18) These different polarization techniques rely on different contrast mechanisms and have their own advantages and disadvantages.”
BackgroundMethodResultInfluentialSelf-citation
Cited by
Polarisation optics for biomedical and clinical applications: a review
He, C., He, H., Chang, J., Chen, B., Ma, H., & Booth, M. J. (2021) · Light: Science & Applications · doi:10.1038/s41377-021-00639-x · Cited by 604
Self-citationPolarized light interaction with tissues
Tuchin, V. V. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.7.071114 · Cited by 384
“2, 5 – 11, 14 – 22, 24, 28, 29, 37 – 42, 46, 48 – 51, 60, 65, 86, 87, 90 – 92, 94, 97, 105, 191 – 195).”
Mueller polarimetric imaging for surgical and diagnostic applications: a review
Qi, J., & Elson, D. S. (2017) · Journal of Biophotonics · doi:10.1002/jbio.201600152 · Cited by 268
Sun, M., He, H., Zeng, N., Du, E., Guo, Y., Liu, S., Wu, J., He, Y., & Ma, H. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.004223 · Cited by 211
Self-citationHe, H., Liao, R., Zeng, N., Li, P., Chen, Z., Liu, X., & Ma, H. (2019) · Journal of Lightwave Technology · doi:10.1109/jlt.2018.2868845 · Cited by 204
“The Mueller matrix parameters can also be used for the detections of human skin cancers such as the basal call carcinoma tissues [133].”
BackgroundSelf-citationWang, Y., He, H., Chang, J., He, C., Liu, S., Li, M., Zeng, N., Wu, J., & Ma, H. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.7.071112 · Cited by 177
Self-citation
Metadata
- Authors
- Du, E., He, H., Zeng, N., Sun, M., Guo, Y., Wu, J., Liu, S., & Ma, H.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2014-07-15
- Volume
- 19
- Issue
- 7
- Pages
- 076013
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2140044882
- Cited by
- 212
- References
- 26
- FWCI
- 7.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.