Beer–Lambert law for optical tissue diagnostics: current state of the art and the main limitations
Open accessThe DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
SIGNIFICANCE: Beer-Lambert law (BLL) is a widely used tool for contact and remote determination of absorber concentration in various media, including living tissues. Originally proposed in the 18th century as a simple exponential expression, it has survived numerous modifications and updates. The basic assumptions of this law may not be fulfilled in real measurement conditions. This can lead to mistaken or misinterpreted results. In particular, the effects to be additionally taken into account in the tissue measurements include anisotropy, scattering, fluorescence, chemical equilibria, interference, dichroism, spectral bandwidth disagreements, stray radiation, and instrumental effects. AIM: We review the current state of the art and the main limitations of remote tissue diagnostics using the BLL. Historical development of updating this law by taking into account specific additional factors such as light scattering and photon pathlengths in diffuse reflectance is described, along with highlighting the main risks to be considered by interpreting the measured data. APPROACH: Literature data related to extension and modification of the BLL related to tissue assessment and concentration estimation of specific tissue molecules are collected and analyzed. The main emphasis here is put on the optical measurements of living tissue chromophore concentrations and estimation of physiological parameters, e.g., blood oxygen saturation. RESULTS: Modified expressions of the BLL suitable for several specific cases of living tissue characterization are presented and discussed. CONCLUSIONS: Applications of updated/modified Beer-Lambert law (MBLL) with respect to particular measurement conditions are helpful for obtaining more reliable data on the target tissue physiological state and biochemical content. MBLL accounting for the role of scattering in several ways appears to be a successful approach. Extended MBLL and BLL in the time domain form could provide more accurate results, but this requires more time resources to be spent.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optical properties of biological tissues: A review
Jacques, S. L. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/11/r37 · Cited by 4,008 · cited 1×
“Efficiency of the Mie and Rayleigh scattering, both taking place in tissues, depends on the light wavelength.(31) In particular, the OPL in a scattering tissue is wavelength dependent and therefore influences absorption.”
BackgroundEstimation of optical pathlength through tissue from direct time of flight measurement
Delpy, D. T., Cope, M., Zee, P. V. D., Arridge, S., Wray, S., & Wyatt, J. (1988) · Physics in Medicine and Biology · doi:10.1088/0031-9155/33/12/008 · Cited by 2,245
Swinehart, D. F. (1962) · Journal of Chemical Education · doi:10.1021/ed039p333 · Cited by 1,969
Fundamentals of analytical chemistry
Vaz, S. (2021) · Elsevier eBooks · doi:10.1016/b978-0-323-85208-1.00006-1 · Cited by 1,634
Bestimmung der Absorption des rothen Lichts in farbigen Flüssigkeiten
Beer (1852) · Annalen der Physik · doi:10.1002/andp.18521620505 · Cited by 936
Beyond the Visible???Imaging the Human Brain With Light
Obrig, H., & Villringer, A. (2003) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200301000-00001 · Cited by 892
The flattering of the absorption spectrum of suspensions, as compared to that of solutions
Duyens, L. N. M. (1956) · Biochimica et Biophysica Acta · doi:10.1016/0006-3002(56)90380-8 · Cited by 718
The modified Beer–Lambert law revisited
Kocsis, L., Herman, P., & Eke, A. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/5/n02 · Cited by 679
The Bouguer-Beer-Lambert Law: Shining Light on the Obscure
Mayerhöfer, T. G., Pahlow, S., & Popp, J. (2020) · ChemPhysChem · doi:10.1002/cphc.202000464 · Cited by 671 · cited 3×
“One reason for this could be that light multiple times is reflected from one surface of the slab and then from the other one.(38) BLL works better for media with lower reflection.”
BackgroundInfluentialA Monte Carlo model of light propagation in tissue
Prahl, S. A. (1989) · SPIE Proceedings · doi:10.1117/12.2283590 · Cited by 616
Tissue oxygenation monitor using NIR spatially resolved spectroscopy:
Suzuki, S., Takasaki, S., Ozaki, T., & Kobayashi, Y. (1999) · SPIE Proceedings · doi:10.1117/12.356862 · Cited by 484
Kienle, A., & Patterson, M. S. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.000246 · Cited by 474
Contini, D., Martelli, F., & Zaccanti, G. (1997) · Applied Optics · doi:10.1364/ao.36.004587 · Cited by 460
Scholkmann, F., & Wolf, M. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.10.105004 · Cited by 450
van der Zee, P., Cope, M., Arridge, S. R., Essenpreis, M., Potter, L. A., Edwards, A. D., Wyatt, J. S., McCormick, D. C., Roth, S. C., Reynolds, E. O. R., et al. (1992) · Advances in Experimental Medicine and Biology · doi:10.1007/978-1-4615-3404-4_17 · Cited by 427
Meglinski, I. V., & Matcher, S. J. (2002) · Physiological Measurement · doi:10.1088/0967-3334/23/4/312 · Cited by 408
Hiraoka, M., Firbank, M., Essenpreis, M., Cope, M., Arridge, S. R., Zee, P. V. D., & Delpy, D. T. (1993) · Physics in Medicine and Biology · doi:10.1088/0031-9155/38/12/011 · Cited by 374
Comment on the modified Beer–Lambert law for scattering media
Sassaroli, A., & Fantini, S. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/14/n07 · Cited by 352
Modified Beer-Lambert law for blood flow
Baker, W. B., Parthasarathy, A. B., Busch, D. R., Mesquita, R. C., Greenberg, J. H., & Yodh, A. G. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.004053 · Cited by 283
Fantini, S., Hueber, D., Franceschini, M. A., Gratton, E., Rosenfeld, W., Stubblefield, P. G., Maulik, D., & Stankovic, M. R. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/6/308 · Cited by 277
A Tissue Oxygenation Monitor using NIR Spatially Resolved Spectroscopy
Suzuki, S. (1999) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · Cited by 227
Hansen, W. N. (1965) · Spectrochimica Acta · doi:10.1016/0371-1951(65)80039-x · Cited by 215
A new method for the measurement of percent oxyhemoglobin
Pittman, R. N., & Duling, B. R. (1975) · Journal of Applied Physiology · doi:10.1152/jappl.1975.38.2.315 · Cited by 120
Hyperspectral imaging in wound care: A systematic review
Saiko, G., Lombardi, P., Au, Y., Queen, D., Armstrong, D. G., & Harding, K. G. (2020) · International Wound Journal · doi:10.1111/iwj.13474 · Cited by 117
Beer's Law‐Why Integrated Absorbance Depends Linearly on Concentration
Mayerhöfer, T. G., Pipa, A. V., & Popp, J. (2019) · ChemPhysChem · doi:10.1002/cphc.201900787 · Cited by 110
Using noninvasive multispectral imaging to quantitatively assess tissue vasculature
Vogel, A. J., Chernomordik, V., Riley, J. D., Hassan, M., Amyot, F., Dasgeb, B., Demos, S. G., Pursley, R. H., Little, R. F., Yarchoan, R., et al. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2801718 · Cited by 103
The Application of the Beer-Lambert Law to Optically Anisotropic Systems
Commoner, B., & Lipkin, D. (1949) · Science · doi:10.1126/science.110.2845.41-a · Cited by 73 · cited 2×
“As a consequence, absorbance is not linearly related to concentration.(14) Oshina and Spigulis: Beer–Lambert law for optical tissue diagnostics: current state of the art.”
BackgroundSmartphone snapshot mapping of skin chromophores under triple-wavelength laser illumination
Spīgulis, J., Oshina, I., Berzina, A., & Bykov, A. V. (2017) · Journal of Biomedical Optics · doi:10.1117/1.jbo.22.9.091508 · Cited by 68
Self-citationEffects of Processing Methods on fNIRS Signals Assessed During Active Walking Tasks in Older Adults
İzzetoğlu, M., & Holtzer, R. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.2970407 · Cited by 66
Kohl‐Bareis, M., Lindauer, U., Dirnagl, U., & Villringer, A. (1998) · Optics Letters · doi:10.1364/ol.23.000555 · Cited by 54
Tsuchiya, Y. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/8/303 · Cited by 51
Relationship between time-resolved and non-time-resolved Beer - Lambert law in turbid media
Nomura, Y., Hazeki, O., & Tamura, M. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/6/002 · Cited by 51
Breakdown of the Lambert-Beer Law
ROSE, H. E. (1952) · Nature · doi:10.1038/169287a0 · Cited by 38 · cited 2×
“In the biological tissues, scattering occurs due to turbidity or the suspended micro-particles.(30) Efficiency of the Mie and Rayleigh scattering, both taking place in tissues, depends on the light wavelength.”
BackgroundHuong, A. K. C., & Ngu, X. T. I. (2014) · Journal of Innovative Optical Health Sciences · doi:10.1142/s1793545814500266 · Cited by 33
Some considerations on apparent deviations from lambert-beer's law
Buijs, K., & Maurice, M. J. (1969) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)95647-8 · Cited by 31
Sato, C., Nemoto, M., & Tamura, M. (2002) · The Japanese Journal of Physiology · doi:10.2170/jjphysiol.52.301 · Cited by 29
Single wavelength measurements of absorption coefficients based on iso-pathlength point
Feder, I., Duadi, H., & Fixler, D. (2020) · Biomedical Optics Express · doi:10.1364/boe.401591 · Cited by 23
Karamavuş, Y., & Özkan, M. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.01.019 · Cited by 17
Deviations from Beer's Law in the Ultraviolet Absorption Spectra of Some Organic Compounds
Ungnade, H. E., Kerr, V., & Youse, E. (1951) · Science · doi:10.1126/science.113.2943.601 · Cited by 14
Tang, Q., Zhao, L., Xie, J., Liu, K., Liu, W., & Zhou, S. (2019) · Chirality · doi:10.1002/chir.23072 · Cited by 10 · cited 2×
“Tang et al.(39) analyzed chiral composition with different concentrations.”
BackgroundModified lambert beer for bilirubin concentration and blood oxygen saturation prediction
Ong, P. E., Huong, A. K. C., Ngu, X. T. I., Mahmud, F., & Philimon, S. P. (2019) · International Journal of Advances in Intelligent Informatics · doi:10.26555/ijain.v5i2.363 · Cited by 8
Metadata
- Authors
- Oshina, I., & Spigulis, J.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2021-10-28
- Volume
- 26
- Issue
- 10
- Pages
- 1-17
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W3210833735
- Cited by
- 273
- References
- 41
- FWCI
- 13.12
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.