Evaluating stability of histomorphometric features across scanner and staining variations: prostate cancer diagnosis from whole slide images
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Quantitative histomorphometry (QH) is the process of computerized feature extraction from digitized tissue slide images to predict disease presence, behavior, and outcome. Feature stability between sites may be compromised by laboratory-specific variables including dye batch, slice thickness, and the whole slide scanner used. We present two new measures, preparation-induced instability score and latent instability score, to quantify feature instability across and within datasets. In a use case involving prostate cancer, we examined QH features which may detect cancer on whole slide images. Using our method, we found that five feature families (graph, shape, co-occurring gland tensor, sub-graph, and texture) were different between datasets in 19.7% to 48.6% of comparisons while the values expected without site variation were 4.2% to 4.6%. Color normalizing all images to a template did not reduce instability. Scanning the same 34 slides on three scanners demonstrated that Haralick features were most substantively affected by scanner variation, being unstable in 62% of comparisons. We found that unstable feature families performed significantly worse in inter- than intrasite classification. Our results appear to suggest QH features should be evaluated across sites to assess robustness, and class discriminability alone should not represent the benchmark for digital pathology feature selection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Breiman, L. (2001) · Machine Learning · doi:10.1023/a:1010933404324 · Cited by 133,538
A method for normalizing histology slides for quantitative analysis
Macenko, M., Niethammer, M., Marron, J. S., Borland, D., Woosley, J. T., Guan, X., Schmitt, C., & Thomas, N. E. (2009) · 2009 IEEE International Symposium on Biomedical Imaging: From Nano to Macro · doi:10.1109/isbi.2009.5193250 · Cited by 1,482
Stacked Sparse Autoencoder (SSAE) for Nuclei Detection on Breast Cancer Histopathology Images
Xu, J., Xiang, L., Liu, Q., Gilmore, H., Wu, J., Tang, J., & Madabhushi, A. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2458702 · Cited by 854
Self-citationCruz-Roa, A. A., Arevalo Ovalle, J. E., Madabhushi, A., & González Osorio, F. A. (2013) · Lecture Notes in Computer Science · doi:10.1007/978-3-642-40763-5_50 · Cited by 403
Self-citationContent-based image retrieval of digitized histopathology in boosted spectrally embedded spaces
Sridhar, A., Doyle, S., & Madabhushi, A. (2015) · Journal of Pathology Informatics · doi:10.4103/2153-3539.159441 · Cited by 34
Self-citation
Cited by
Artificial intelligence in digital pathology — new tools for diagnosis and precision oncology
Bera, K., Schalper, K. A., Rimm, D. L., Velcheti, V., & Madabhushi, A. (2019) · Nature Reviews Clinical Oncology · doi:10.1038/s41571-019-0252-y · Cited by 1,698
Self-citationPantanowitz, L., Quiroga-Garza, G. M., Bien, L., Heled, R., Laifenfeld, D., Linhart, C., Sandbank, J., Albrecht Shach, A., Shalev, V., Vecsler, M., et al. (2020) · The Lancet Digital Health · doi:10.1016/s2589-7500(20)30159-x · Cited by 360
Li, X., Li, C., Rahaman, M. M., Sun, H., Li, X., Wu, J., Yao, Y., & Grzegorzek, M. (2022) · Artificial Intelligence Review · doi:10.1007/s10462-021-10121-0 · Cited by 278
Digital pathology and computational image analysis in nephropathology
Barisoni, L., Lafata, K. J., Hewitt, S. M., Madabhushi, A., & Balis, U. G. J. (2020) · Nature Reviews Nephrology · doi:10.1038/s41581-020-0321-6 · Cited by 264
Self-citationAmgad, M., Stovgaard, E. S., Balslev, E., Thagaard, J., Chen, W., Dudgeon, S., Sharma, A., Kerner, J. K., Denkert, C., Yuan, Y., et al. (2020) · npj Breast Cancer · doi:10.1038/s41523-020-0154-2 · Cited by 171
“Pre-AV is of paramount importance, as CTA algorithm performance may vary in the presence of artifacts, variability in staining, tissue thickness, cutting angle, imaging, and storage 65 – 68 .”
MethodSelf-citation
Metadata
- Authors
- Leo, P., Lee, G., Shih, N. N. C., Elliott, R., Feldman, M. D., & Madabhushi, A.
- Venue
- Journal of Medical Imaging
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2016-10-24
- Volume
- 3
- Issue
- 4
- Pages
- 047502
- ISSN
- 2329-4302 (ISSN-L)
- OpenAlex
- W2537109170
- Cited by
- 72
- References
- 5
- FWCI
- 6.64
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.