The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
How short is short? Optimum source–detector distance for short-separation channels in functional near-infrared spectroscopy
Open accessAbstract
In recent years, it has been demonstrated that using functional near-infrared spectroscopy (fNIRS) channels with short separations to explicitly sample extra-cerebral tissues can provide a significant improvement in the accuracy and reliability of fNIRS measurements. The aim of these short-separation channels is to measure the same superficial hemodynamics observed by standard fNIRS channels while also being insensitive to the brain. We use Monte Carlo simulations of photon transport in anatomically informed multilayer models to determine the optimum source-detector distance for short-separation channels in adult and newborn populations. We present a look-up plot that provides (for an acceptable value of short-separation channel brain sensitivity relative to standard channel brain sensitivity) the optimum short-separation distance. Though values vary across the scalp, when the acceptable ratio of the short-separation channel brain sensitivity to standard channel brain sensitivity is set at 5%, the optimum short-separation distance is 8.4 mm in the typical adult and 2.15 mm in the term-age infant.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
Unbiased average age-appropriate atlases for pediatric studies
Fonov, V., Evans, A. C., Botteron, K., Almli, C. R., McKinstry, R. C., & Collins, D. L. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.07.033 · Cited by 2,290
Fang, Q., & Boas, D. A. (2009) · Optics Express · doi:10.1364/oe.17.020178 · Cited by 1,003
Lloyd-Fox, S., Blasi, A., & Elwell, C. E. (2010) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2009.07.008 · Cited by 865
Tetrahedral mesh generation from volumetric binary and grayscale images
Fang, Q., & Boas, D. A. (2009) · 2009 IEEE International Symposium on Biomedical Imaging: From Nano to Macro · doi:10.1109/isbi.2009.5193259 · Cited by 691
The enigma of Mayer waves: facts and models.
JULIEN, C. (2006) · Cardiovascular Research · doi:10.1016/j.cardiores.2005.11.008 · Cited by 670
A finite element approach for modeling photon transport in tissue
Arridge, S. R., Schweiger, M., Hiraoka, M., & Delpy, D. T. (1993) · Medical Physics · doi:10.1118/1.597069 · Cited by 635
Spontaneous Low Frequency Oscillations of Cerebral Hemodynamics and Metabolism in Human Adults
Obrig, H., Neufang, M., Wenzel, R., Kohl, M., Steinbrink, J., Einhäupl, K., & Villringer, A. (2000) · NeuroImage · doi:10.1006/nimg.2000.0657 · Cited by 614
Strangman, G., Franceschini, M. A., & Boas, D. A. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00021-1 · Cited by 581
The physiological origin of task-evoked systemic artefacts in functional near infrared spectroscopy
Kirilina, E., Jelzow, A., Heine, A., Niessing, M., Wabnitz, H., Brühl, R., Ittermann, B., Jacobs, A. M., & Tachtsidis, I. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.02.074 · Cited by 499
In vivo local determination of tissue optical properties: applications to human brain
Bevilacqua, F., Piguet, D., Marquet, P., Gross, J. D., Tromberg, B. J., & Depeursinge, C. (1999) · Applied Optics · doi:10.1364/ao.38.004939 · Cited by 456
Short separation channel location impacts the performance of short channel regression in NIRS
Gagnon, L., Cooper, R. J., Yücel, M. A., Perdue, K. L., Greve, D. N., & Boas, D. A. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.08.095 · Cited by 312
Self-citationFukui, Y., Ajichi, Y., & Okada, E. (2003) · Applied Optics · doi:10.1364/ao.42.002881 · Cited by 286
Gagnon, L., Perdue, K., Greve, D. N., Goldenholz, D., Kaskhedikar, G., & Boas, D. A. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.03.001 · Cited by 278
Direct characterization and removal of interfering absorption trends in two-layer turbid media
Saager, R. B., & Berger, A. J. (2005) · Journal of the Optical Society of America A · doi:10.1364/josaa.22.001874 · Cited by 271
Strangman, G. E., Li, Z., & Zhang, Q. (2013) · PLoS ONE · doi:10.1371/journal.pone.0066319 · Cited by 262
Gagnon, L., Yücel, M. A., Boas, D. A., & Cooper, R. J. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.01.073 · Cited by 200
Self-citationZhang, Q., Strangman, G. E., & Ganis, G. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.12.048 · Cited by 176
Gregg (2010) · Frontiers in Neuroenergetics · doi:10.3389/fnene.2010.00014 · Cited by 161
Scalp and skull influence on near infrared photon propagation in the Colin27 brain template
Strangman, G. E., Zhang, Q., & Li, Z. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.04.090 · Cited by 156
Saager, R. B., & Berger, A. J. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2940587 · Cited by 155
Custo, A., Wells, W. M., Barnett, A. H., Hillman, E. M. C., & Boas, D. A. (2006) · Applied Optics · doi:10.1364/ao.45.004747 · Cited by 147
Beauchamp, M. S., Beurlot, M. R., Fava, E., Nath, A. R., Parikh, N. A., Saad, Z. S., Bortfeld, H., & Oghalai, J. S. (2011) · PLoS ONE · doi:10.1371/journal.pone.0024981 · Cited by 118
Li, T., Gong, H., & Luo, Q. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3567085 · Cited by 99
Near infrared technology in neuroscience: past, present and future
Calderon‐Arnulphi, M., Alaraj, A. M., & Slavin, K. V. (2009) · Neurological Research · doi:10.1179/174313209x383286 · Cited by 95
Accelerating mesh-based Monte Carlo method on modern CPU architectures
Fang, Q., & Kaeli, D. R. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.003223 · Cited by 86
Taga, G., Homae, F., & Watanabe, H. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.07.050 · Cited by 83
Goodwin, J. R., Gaudet, C. R., & Berger, A. J. (2014) · Neurophotonics · doi:10.1117/1.nph.1.1.015002 · Cited by 74
A 4D neonatal head model for diffuse optical imaging of pre-term to term infants
Brigadoi, S., Aljabar, P., Deprez, M., Arridge, S., & Cooper, R. J. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.06.028 · Cited by 73
Self-citationScarpa, F., Brigadoi, S., Cutini, S., Scatturin, P., Zorzi, M., Dell’Acqua, R., & Sparacino, G. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.01.021 · Cited by 59
Self-citationBabiloni, F., Babiloni, C., Carducci, F., Gaudio, M. D., Onorati, P., & Urbano, A. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(97)00035-7 · Cited by 31
Probabilistic atlas can improve reconstruction from optical imaging of the neonatal brain
Heiskala, J., Pollari, M., Metsäranta, M., Grant, P. E., & Nissila, I. T. (2009) · Optics Express · doi:10.1364/oe.17.014977 · Cited by 28
Perdue, K. L., & Diamond, S. G. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.2.026011 · Cited by 26
Wang, S., Shibahara, N., Kuramashi, D., Okawa, S., Kakuta, N., Okada, E., Maki, A., & Yamada, Y. (2010) · Optical Review · doi:10.1007/s10043-010-0076-6 · Cited by 22
Cited by
Tachtsidis, I., & Scholkmann, F. (2016) · Neurophotonics · doi:10.1117/1.nph.3.3.031405 · Cited by 607
Best practices for fNIRS publications
Yücel, M. A., Lühmann, A. V., Scholkmann, F., Gervain, J., Dan, I., Ayaz, H., Boas, D., Cooper, R. J., Culver, J., Elwell, C. E., et al. (2021) · Neurophotonics · doi:10.1117/1.nph.8.1.012101 · Cited by 492
Self-citationHerold, F., Wiegel, P., Scholkmann, F., & Müller, N. (2018) · Journal of Clinical Medicine · doi:10.3390/jcm7120466 · Cited by 482
Quaresima, V., & Ferrari, M. (2019) · Organizational Research Methods · doi:10.1177/1094428116658959 · Cited by 419
Zimeo Morais, G. A., Balardin, J. B., & Sato, J. R. (2018) · Scientific Reports · doi:10.1038/s41598-018-21716-z · Cited by 375
Metadata
- Authors
- Brigadoi, S., & Cooper, R. J.
- Venue
- Neurophotonics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2015-05-26
- Volume
- 2
- Issue
- 2
- Pages
- 025005
- ISSN
- 2329-423X (ISSN-L)
- OpenAlex
- W2139759629
- Cited by
- 328
- References
- 35
- FWCI
- 11.09
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.