Phase modulation system for dual wavelength difference spectroscopy of hemoglobin deoxygenation in tissues
The DOI matches its Crossref record.
Abstract
Time resolved spectroscopy of tissue makes it possible to quantify tissue hemoglobin concentrations because of the direct measurement of the optical path length for photon migration. However, the laser system is bulky and unwieldy and impractical for clinical studies. Thus, the application of the more compact and efficient phase modulation technology well known for fluorescence lifetime studies to time resolved spectroscopy of tissue offers opportunities to simplify the methodology and in addition to afford continuous readout of tissue photon propagation. This paper describes single and dual wavelength systems operating at two wavelengths in the deep red region based upon a time-sharing system. These devices have noise levels in a 2 Hz bandwidth of less than 2 ps and drifts of < 1ps/min. Applications of the noninvasive devices include measurement of hemoglobin deoxygenation in brain and hemoglobin and myoglobin deoxygenation in human skeletal muscle and animal models. Numerous applications to medical and biological problems now become available.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Duncan, A., Meek, J. H., Clemence, M., Elwell, C. E., Tyszczuk, L., Cope, M., & Delpy, D. (1995) · Physics in Medicine and Biology · doi:10.1088/0031-9155/40/2/007 · Cited by 649
Arridge, S. R., Cope, M., & Delpy, D. T. (1992) · Physics in Medicine and Biology · doi:10.1088/0031-9155/37/7/005 · Cited by 595
Quantification in tissue near–infrared spectroscopy
Delpy, D. T., & Cope, M. (1997) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.1997.0046 · Cited by 507
Okada, E., Firbank, M., Schweiger, M., Arridge, S. R., Cope, M., & Delpy, D. T. (1997) · Applied Optics · doi:10.1364/ao.36.000021 · Cited by 477
Duncan, A., Meek, J. H., Clemence, M., Elwell, C. E., Fallon, P., Tyszczuk, L., Cope, M., & Delpy, D. T. (1996) · Pediatric Research · doi:10.1203/00006450-199605000-00025 · Cited by 469
Metadata
- Authors
- Chance, B., Maris, M. B., Sorge, J., & Zhang, M. Z.
- Venue
- SPIE Proceedings
- Publisher
- SPIE
- Published
- 1990-05-01
- Volume
- 1204
- Pages
- 481-481
- ISSN
- 0277-786X (ISSN-L)
- OpenAlex
- W2029181858
- Cited by
- 94
- References
- 0
- FWCI
- 16.31
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Phase modulation system for dual wavelength difference spectroscopy of hemoglobin deoxygenation in tissues. https://app.cochat.ai/papers/10.1117/12.17711
- The paper
- Chance, B., Maris, M. B., Sorge, J., & Zhang, M. Z. (1990). Phase modulation system for dual wavelength difference spectroscopy of hemoglobin deoxygenation in tissues. SPIE Proceedings. https://doi.org/10.1117/12.17711
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.