Study of Dill's B parameter measurement of EUV resist
Abstract
Our group previously explored methods for measuring simulation parameter for advanced chemically amplified (CA) resists, including development parameters [1]. Dill’s C parameter [2-3] , acid diffusion length generated from PAG [4], and de-protection reaction parameters [5-6]. We performed simulations of EUV resists using these parameters, the results of which allowed us to examine the conditions for reducing LER and improving resolution. This paper discusses a method for measuring the Dill’s B parameter, which had been difficult to measure with conventional methods. We also confirmed that enhancing the resist polymer’s EUV light absorption is effective in improving the sensitivity of the CA resist.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
A notable study discovered a correlation between the transmissivity of photoresists at EUV wavelengths and the amount of incorporated tellurium.
“One notable study discovered a correlation between the transmissivity of photoresists at EUV wavelengths and the amount of incorporated tellurium [29].”
From Recent Advances in Metal-Oxide-Based Photoresists for EUV Lithography (2024) · cites this paper as [29]
Cites
EUV resists based on tin-oxo clusters
Cardineau, B., Del Re, R., Al-Mashat, H., Marnell, M., Vockenhuber, M., Ekinci, Y., Sarma, C., Neisser, M., Freedman, D. A., & Brainard, R. L. (2014) · SPIE Proceedings · doi:10.1117/12.2046536 · Cited by 67 · see citing works
Flagged first, then by citations
Research works printed but not linked: 7
- Sekiguchi Atsushi and Matsumoto Yoko, “A Study of acid diffusion behaviors from PAG by using tio coat method for ArF Lithography”, proc. of SPIE, vol. 9051, pp.9051 90511S1–90511S13, 2014 · DOI
- 10.2494/photopolymer.27.623 · DOI
- 10.2494/photopolymer.16.209 · DOI
- 10.2494/photopolymer.27.595 · DOI
- 10.2494/photopolymer.22.85 · DOI
- 10.1143/JJAP.44.5556 · DOI
- Bakshi Vivek “EUV Lithography”, SPIE (WILEY INTERCIENCE), PP. 392–394
Cited by
Sorted by citations
Absorption coefficient of metal-containing photoresists in the extreme ultraviolet
Fallica, R., Haitjema, J., Wu, L., Castellanos Ortega, S., Brouwer, A. M., & Ekinci, Y. (2018) · Journal of Micro/Nanopatterning Materials and Metrology · doi:10.1117/1.jmm.17.2.023505 · Cited by 105 · see citing works
Recent Advances in Metal-Oxide-Based Photoresists for EUV Lithography
Hasan, M. W., Deeb, L., Kumaniaev, S., Wei, C., & Wang, K. (2024) · Micromachines · doi:10.3390/mi15091122 · Cited by 29 · see citing works
- Authors
- Sekiguchi, A., Matsumoto, Y., Harada, T., Watanabe, T., & Kinoshita, H.
- Affiliations
- Litho Tech Japan Corporation (Japan) (JP)
- University of Hyogo (JP)
- Venue
- SPIE Proceedings
- Publisher
- SPIE
- Published
- 2015-03-13
- Volume
- 9422
- Pages
- 94222L
- ISSN
- 0277-786X (ISSN-L)
- OpenAlex
- W1998302214
- Cited by
- 10
- References
- 1
- Citations by year
- 2025: 1 · 2024: 2 · 2018: 3 · 2016: 3 · 2015: 1
- FWCI
- 2.89
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advancements in Photolithography Techniques
- Physical Sciences › Chemistry › Organic Chemistry › Photopolymerization techniques and applications
- Physical Sciences › Physics and Astronomy › Radiation › Advanced X-ray Imaging Techniques
- Keywords
- EUV resist, chemically amplified resists, periaqueductal gray, line edge roughness, resolution, resist sensitivity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review