The DOI matches its Crossref record.
EUV photomask defects: what prints, what doesn't, and what is required for HVM
Abstract
As Extreme Ultraviolet (EUV) lithography has matured, numerous imposing technical challenges have been the focus of intense scrutiny, including the EUV radiation source, reflective optics, and fundamental mask fabrication. There has been a lurking question on the state of mask defectivity that has been almost unanswerable until the recent relative maturation of the rest of the infrastructure. Without readily available actinic blank or patterned inspection systems, EUV blank and mask manufacturers must continue to rely on relatively low resolution optical systems for blank characterization. Despite best efforts, detectable defects still exist; these can be classified into three types: small defects that can be avoided through pattern-shift, medium defects that can be repaired, and large defects which must be suppressed during manufacture. To successfully intercept high-volume-manufacturing (HVM) for the 7nm node, aggressive, continued industry focus is required to ensure that these three defect types are addressed. Without actinic mask inspection, an unknown element with EUV lithography continues to be the presence of nondetected printable defects – defects that print on wafer despite being undetected during mask or blank fabrication. Another risk is that until recently, focus has been on developing techniques to identify catastrophic defects, while past manufacturing experience tells us that much more subtle defects (<10% CD variation) can have significant impact on yield and performance. Using information from many characterization sources, including blank inspections, patterned inspection, atomic-force microscopy (AFM), scanning-electron microscopy (SEM), as well as 36nm and 32nm pitch wafer printing results, we will try to address what the real current state of mask defectivity is. We will discuss techniques to answer the key questions of: “What defects print, what defects do not, and what might our inspections methods be missing?” From this vantage point, we will analyze the current mask defectivity rates and sources, and assess the gap in capability to support full HVM support.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Assuming normally distributed absorbed photons and normally distributed effective resist blur, several 7σ events in effective sensitivity are possible for population sizes in the trillions.
“Assuming normally distributed absorbed photons and normally dis- tributed effective resi st blur, several 7 σ events in effective sensitivity are possible for population sizes in the trillions 106 .”
From Extreme ultraviolet lithography (2024) · cites this paper as [106]
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 1
- Goldberg, K.A., Sematech Mask Cleaning Workshop, (2010)
Cited by
Sorted by citations
Extreme ultraviolet lithography
Kazazis, D., Santaclara, J. G., van Schoot, J., Mochi, I., & Ekinci, Y. (2024) · Nature Reviews Methods Primers · doi:10.1038/s43586-024-00361-z · Cited by 149
Metadata
- Authors
- Rankin, J., Qi, Z. J., Lawliss, M., Narita, E., Seki, K., Badger, K., Bonam, R., Halle, S., & Turley, C.
- Affiliations
- GlobalFoundries (United States) (US)
- Toppan (United States) (US)
- IBM (United States) (US)
- Venue
- SPIE Proceedings
- Publisher
- SPIE
- Published
- 2015-10-23
- Volume
- 9635
- Pages
- 96350L
- ISSN
- 0277-786X (ISSN-L)
- OpenAlex
- W1851010393
- Cited by
- 12
- References
- 0
- Citations by year
- 2024: 1 · 2023: 1 · 2022: 1 · 2016: 7 · 2015: 2
- FWCI
- 3.72
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advancements in Photolithography Techniques
- Physical Sciences › Engineering › Industrial and Manufacturing Engineering › Industrial Vision Systems and Defect Detection
- Physical Sciences › Physics and Astronomy › Radiation › Advanced X-ray Imaging Techniques
- Keywords
- EUV masks, defect classification, defect repair, defect reduction, high-volume manufacturing, 7nm technology node, EUV lithography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review