An automated framework for image classification and segmentation of fetal ultrasound images for gestational age estimation
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Accurate assessment of fetal gestational age (GA) is critical to the clinical management of pregnancy. Industrialized countries rely upon obstetric ultrasound (US) to make this estimate. In low- and middle- income countries, automatic measurement of fetal structures using a low-cost obstetric US may assist in establishing GA without the need for skilled sonographers. In this report, we leverage a large database of obstetric US images acquired, stored and annotated by expert sonographers to train algorithms to classify, segment, and measure several fetal structures: biparietal diameter (BPD), head circumference (HC), crown rump length (CRL), abdominal circumference (AC), and femur length (FL). We present a technique for generating raw images suitable for model training by removing caliper and text annotation and describe a fully automated pipeline for image classification, segmentation, and structure measurement to estimate the GA. The resulting framework achieves an average accuracy of 93% in classification tasks, a mean Intersection over Union accuracy of 0.91 during segmentation tasks, and a mean measurement error of 1.89 centimeters, finally leading to a 1.4 day mean average error in the predicted GA compared to expert sonographer GA estimate using the Hadlock equation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Region Filling and Object Removal by Exemplar-Based Image Inpainting
Criminisi, A., Perez, P., & Toyama, K. (2004) · IEEE Transactions on Image Processing · doi:10.1109/tip.2004.833105 · Cited by 3,258 · cited 1×
“First, an inpainting technique for object removal is employed to erase calipers from a set of images.(14,15) This algorithm takes as input an image and the target region.”
MethodRoad Extraction by Deep Residual U-Net
Zhang, Z., Liu, Q., & Wang, Y. (2018) · IEEE Geoscience and Remote Sensing Letters · doi:10.1109/lgrs.2018.2802944 · Cited by 3,179
Alkema, L., Chou, D., Hogan, D., Zhang, S., Moller, A.-B., Gemmill, A., Fat, D. M., Boerma, T., Temmerman, M., Mathers, C., et al. (2016) · The Lancet · doi:10.1016/s0140-6736(15)00838-7 · Cited by 2,261
SonoNet: Real-Time Detection and Localisation of Fetal Standard Scan Planes in Freehand Ultrasound
Baumgartner, C. F., Kamnitsas, K., Matthew, J., Fletcher, T. P., Smith, S., Koch, L. M., Kainz, B., & Rueckert, D. (2017) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2712367 · Cited by 416
Burgos-Artizzu, X. P., Coronado-Gutiérrez, D., Valenzuela-Alcaraz, B., Bonet-Carne, E., Eixarch, E., Crispi, F., & Gratacós, E. (2020) · Scientific Reports · doi:10.1038/s41598-020-67076-5 · Cited by 240 · cited 1×
“3%).(10) Others have explored the classification and measurement of the fetal head from images selected from free-hand US sweeps(11,12) with high accuracy.”
BackgroundUltrasound‐based gestational‐age estimation in late pregnancy
Papageorghiou, A. T., Kemp, B., Stones, W., Ohuma, E. O., Kennedy, S. H., Purwar, M., Salomon, L. J., Altman, D. G., Noble, J. A., Bertino, E., et al. (2016) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.15894 · Cited by 179
Sridar, P., Kumar, A., Quinton, A., Nanan, R., Kim, J., & Krishnakumar, R. (2019) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2018.11.016 · Cited by 70
Cited by
Use of artificial intelligence and deep learning in fetal ultrasound imaging
Ramirez Zegarra, R., & Ghi, T. (2023) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.26130 · Cited by 102
Artificial intelligence in obstetric ultrasound: A scoping review.
Horgan, R., Nehme, L., & Abuhamad, A. (2023) · Prenatal Diagnosis · doi:10.1002/pd.6411 · Cited by 72
Jost, E., Kosian, P., Jimenez Cruz, J., Albarqouni, S., Gembruch, U., Strizek, B., & Recker, F. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12216833 · Cited by 44
“The purpose of these studies, which were based on US data from the US and Zambia, was the successful establishment of an AI algorithm for GA estimation from simplified blind US sweeps of US novices in low-resource countries [144,145,152,153].”
BackgroundWalker, M. C., Willner, I., Miguel, O. X., Murphy, M. S. Q., El-Chaâr, D., Moretti, F., Dingwall Harvey, A. L. J., Rennicks White, R., Muldoon, K. A., Carrington, A. M., et al. (2022) · PLOS ONE · doi:10.1371/journal.pone.0269323 · Cited by 31
Metadata
- Authors
- Prieto, J. C., Shah, H., Rosenbaum, A., Jiang, X., Musonda, P., Price, J., Stringer, E. M., Vwalika, B., Stamilio, D., & Stringer, J.
- Venue
- Medical Imaging 2021: Image Processing
- Publisher
- SPIE
- Published
- 2021-02-15
- Volume
- 11596
- Pages
- 55
- OpenAlex
- W3129770665
- Cited by
- 21
- References
- 7
- FWCI
- 1.39
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.