Automatic quality control of segmentation results using early epochs as data augmentation: application to choroid plexuses

Open access
Yazdan-Panah, Arya, Stankoff, Bruno, Colliot, Olivier·2024·Medical Imaging 2024: Image Processing

Abstract

The establishment of automated image segmentation methods in medical imaging allows the analysis of very large datasets. However, visual quality control (QC) of segmentation results is impractical in large datasets, hence the need for automatic QC. In this paper, we introduce a novel automatic approach for QC of segmentation results. We developed a QC deep learning model (referred to as QC model) that, for a given patient, predicts the accuracy of the corresponding automatic segmentation (in our work the Dice score) provided by a deep learning segmentation model (referred to as segmentation model) in the absence of a ground truth annotation. To train the QC model, we introduce data augmentation by using the early epochs of the segmentation model. These early epochs allow us to feed the training of the QC model with examples of poor segmentation. We applied our approach to the QC of automatic segmentation of the choroid plexuses of the brain from MRI in controls and patients with multiple sclerosis. However, the method is generic and could be used with any segmentation model. The experiments showed that the proposed approach is very effective for predicting the segmentation accuracy with a correlation coefficient of 0.92, an R2 of 0.763, a mean absolute error (MAE) of 0.078, and a mean squared error (MSE) of 0.009. Overall, this work shall provide a valuable tool for the automatic QC of segmentation results.

AI snapshot

Written from the paper’s full text.

TL;DR

The paper proposes an automatic quality-control model that predicts the Dice accuracy of a deep-learning segmentation without ground truth, using early-epoch segmentations from the segmentation model as data augmentation. Applied to choroid plexus MRI segmentation in multiple sclerosis, radiologically isolated syndrome, and controls, it achieved test correlation 0.92, R² 0.763, MAE 0.078, and MSE 0.009.

Key findings

  • On the validation set, the best model (conv7fc3 + L1 loss + data augmentation) reached MAE 0.052±0.001, MSE 0.005±0.000, ρ 0.941, and R² 0.885; MSE loss with augmentation was similar (MAE 0.059±0.001, MSE 0.005±0.000, ρ 0.94, R² 0.873).
  • On the independent test set, the proposed approach (conv7fc3 + L1 loss + data augmentation) achieved MAE 0.078±0.001, MSE 0.009±0.000, ρ 0.920, and R² 0.763.
  • Models trained without data augmentation performed poorly, even worse than the trivial model: for example, L1 loss without augmentation had MAE 0.190±0.005, MSE 0.063±0.003, ρ 0.056, and R² -0.594, while the trivial model had MAE 0.165±0.004, MSE 0.040±0.002, and R² 0.
  • MRAE loss with augmentation performed worse than L1 or MSE loss with augmentation on validation (MAE 0.106±0.002, MSE 0.015±0.000, ρ 0.9, R² 0.625).

Methods

  • The QC model is a convolutional neural network with 7 convolutional and 3 fully connected layers (conv7fc3), dropout 0.5, trained to predict the Dice score between automatic and manual segmentation from the image and automatic segmentation.
  • Data came from a previously published choroid plexus segmentation model: 168 scans from MS (N=97), RIS (N=27), and healthy controls (N=44), split at subject level into training (72 subjects, 3960 image-segmentation pairs), validation (19 subjects, 1045 pairs), and testing (77 subjects, 4235 pairs).
  • Training used 5-fold cross-validation, PyTorch, weighted Adam with initial learning rate 10⁻³, batch size 17, and two phases: 10 epochs with data augmentation and 100 epochs without. Data augmentation used early-epoch segmentations from the segmentation model; performance was assessed with MAE, MSE, R², and Pearson correlation, comparing with/without augmentation, different losses, and a trivial mean-prediction model.

Limitations

  • The paper states that test performance was slightly lower than validation performance and that this requires further investigation, as it may indicate slight overfitting of the validation set by trying different approaches and losses.
  • Evident from the text: Table 1 reports validation and testing results on one fold despite the stated use of 5-fold cross-validation, so fold-to-fold variability is not shown in the reported table.
  • Evident from the text: evaluation is limited to Dice score and choroid plexus segmentation, although the authors state the method is generic and could be applied to other segmentation models.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1117/12.3006580

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Claims the paper makes

2 of 2 cited sources checked · 1 supported · 0 flagged · accuracy not yet measured

  • Findingown data

    On the test set, the performances of the proposed approach were lower than on the validation set.

    “On the test set, the performances of the proposed approach remained very good (correlation of 0.92, MAE of 0.078) but were lower than on the validation set.”
    • Also stated in: § 4. DISCUSSION · plain
      “However, the performance was slightly lower than those obtained on the validation set.”
    Quote in the paperNot a substantial claim
    • Rests on an assumption: Manual segmentations used as ground truth are accurate.
  • Findingown data

    All models trained without data augmentation performed poorly, even worse than the trivial model.

    “All models trained without DA performed poorly, even worse than the trivial model.”
    Quote in the paperSubstantial claim
    • Rests on an assumption: Manual segmentations used as ground truth are accurate.
  • Findingown data

    On the test set, the proposed approach achieved an R2 of 0.763.

    “an R 2 of 0.763”
    • Also stated in: § 4. DISCUSSION · plain
      “coefficient of determination (R 2 = 0.763)”
    Quote in the paperSubstantial claim
    • Rests on an assumption: Manual segmentations used as ground truth are accurate.
  • Findingown data

    On the test set, the proposed approach achieved a correlation coefficient of 0.92.

    “with a correlation coefficient of 0.92”
    • Also stated in: § 3. EXPERIMENTS AND RESULTS · plain
      “On the test set, the performances of the proposed approach remained very good (correlation of 0.92, MAE of 0.078) but were lower than on the validation set.”
    Quote in the paperSubstantial claim
    • Rests on an assumption: Manual segmentations used as ground truth are accurate.
  • Findingown data

    On the test set, the proposed approach achieved a mean absolute error (MAE) of 0.078.

    “a mean absolute error (MAE) of 0.078”
    • Also stated in: § 3. EXPERIMENTS AND RESULTS · plain
      “MAE of 0.078”
    Quote in the paperSubstantial claim
    • Rests on an assumption: Manual segmentations used as ground truth are accurate.
  • Classified as probably not a substantial claim. 9
  • May combine two claims. 4
  • The quote only partly states this claim. 1
  • Classified as probably not a substantial claim.

    Premisecitation

    Auto-encoder-like QC methods may not be best-suited to objects of interest that present highly variable spatial conformation between subjects and even between visits for the same subject.

    “These types of methods may however not be best-suited to objects of interest that present highly variable spatial conformation between subjects and even between visits for the same subject.”
    Quote in the paperSubstantial claim1 of 1 sources checked
    • cites [21] Galati, 2021, Efficient model monitoring for quality control in cardiac image segmentation source

      The Introduction (p. 2) says the autoencoder models variability in cardiac segmentation masks, while its warning about major morphological deformations concerns an atlas-registration method, not autoencoder-based QC. The Discussion (p. 8) identifies poor sensitivity to small segmentation errors, but does not say these methods are ill-suited to variation between subjects or visits. Searches for spatial conformation and inter- or intra-subject variation found no passage making that claim. (LLM, conf=0.75)

      Experimental — accuracy not yet measured
  • Classified as probably not a substantial claim. May combine two claims.

    Premisecitation

    The segmentation model used in this study was previously published and segments the choroid plexuses of the brain from T1-weighted MRI.

    “For this study, we utilized a previously published segmentation model that segments the choroid plexuses of the brain T1-weighted (T1w) from magnetic resonance imaging (MRI) scans 22”
    Quote in the paperSubstantial claim1 of 1 sources checked
  • The quote only partly states this claim.

    Findingown data

    On the test set, the proposed approach achieved a mean squared error (MSE) of 0.009.

    “a mean squared error (MSE) of 0.009”
    Quote in the paperNot a substantial claim
    • Rests on an assumption: Manual segmentations used as ground truth are accurate.
  • May combine two claims.

    Findingown data

    On the validation set, the best performances are obtained with models trained with data augmentation, notably with L1loss and MSEloss, while MRAEloss showed poorer performances.

    “On the validation set, the best performances are obtained with the models trained with DA, notably with L1loss and MSEloss, while MRAEloss showed poorer performances.”
    Quote in the paperSubstantial claim
    • Rests on an assumption: Manual segmentations used as ground truth are accurate.
  • Probably not a substantial claim: may not pass S2 (checkable).

    Premisereasoning

    It is necessary to perform quality control of segmentation results to identify poor segmentations that can bias subsequent analyses.

    “Even though the performances of the automatic segmentation models are remarkable, it remains necessary to perform quality control (QC) of segmentation results in order to identify poor segmentations which can bias subsequent analyses.”
    Quote in the paperNot a substantial claim
  • Classified as probably not a substantial claim. May combine two claims.

    Premisenone given

    Manual annotation of segmentation quality requires manual labeling and suffers from possible subjectivity of the annotator.

    “This method requires manual labeling and suffers from a possible subjectivity of the annotator.”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Study design and conductreasoning

    Dropout with a 0.5 probability was implemented to avoid overfitting.

    “To avoid overfitting, we implemented dropout with a 0.5 probability.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S4 (based). May combine two claims.

    Premisenone given

    Visual quality control of segmentation results is time-consuming and may be impractical for very large datasets.

    “However, visual QC is time-consuming and may thus be impractical for very large datasets.”
    • Also stated in: § Abstract · plain
      “visual quality control (QC) of segmentation results is impractical in large datasets”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Study design and conductnone given

    All training procedures were carried out using 5-fold cross-validation.

    “All training procedures were carried out using 5-fold cross-validation.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing), S4 (based).

    Interpretationnone given

    The proposed QC method is generic and could be used with any segmentation model.

    “However, the method is generic and could be used with any segmentation model.”
    • Also stated in: § 1. INTRODUCTION · hedged
      “but this concept could be easily applied to other tasks.”
    Quote in the paperNot a substantial claim
  • Classified as probably not a substantial claim.

    Premisenone given

    Training a QC model to predict a segmentation accuracy metric requires a large and diverse set of segmentation outputs together with manual segmentation ground truth.

    “However, the training requires a large and diverse set of segmentation outputs together with manual segmentation ground truth.”
    Quote in the paperSubstantial claim
11 of 11
  • The paper relies on this without support.

    Manual segmentations used as ground truth are accurate.

    “S m the manual segmentation (ground-truth)”
    “manual segmentation ground truth”
1 of 1

Cites

Flagged first, then by citations

Research works printed but not linked: 2

  1. 10.1002/jmri.v50.4 · DOI
  2. Biewald, 2020, Experiment tracking with weights and biases, Software available from wandb. com, 2, 233

Cited by

Sorted by citations

Authors
Yazdan-Panah, A., Stankoff, B., & Colliot, O.
Affiliations
Centre National de la Recherche Scientifique (FR)
Venue
Medical Imaging 2024: Image Processing
Publisher
SPIE
Published
2024-04-02
Pages
44
OpenAlex
W4393408098
Cited by
1
References
25
Citations by year
2025: 1
FWCI
0.21
Type
conference paper
Language
en
Open access
Licence
cc-by
Locations
  • SPIE Medical Imaging: Image Processing (publishedVersion)
  • HAL (Le Centre pour la Communication Scientifique Directe) (submittedVersion, cc-by)
Funders
  • Agence Nationale de la Recherche (ANR-10-IAIHU06, ANR‐19, 10-IAIHU-06, ANR-19-P3IA-0001, ANR-10, ANR-10-IAHU-0006)
  • Grand Équipement National De Calcul Intensif
Topics
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
  • Life Sciences › Neuroscience › Neurology › Brain Tumor Detection and Classification
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Advanced Neural Network Applications
Keywords
automated quality control, segmentation quality assessment, multiple sclerosis, brain MRI, ground truth-free evaluation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Claims read by deepseek-v4.1-flash under definition version 3 (extract-v3) on 2026-10-22.

Classified by jev-1.13-20260917 (gold-guideline-v0.2) on 2026-10-22.

Cited sources are checked by gpt-6-sol.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review