Influence of adipose tissue on muscle oxygenation measurement with an NIRS instrument:
The DOI matches its Crossref record.
Abstract
The influence of the subcutaneous adipose tissue on near infra-red light propagation in leg muscle and on the sensitivity of NIR O2 monitor is investigated. The simulation model is half infinite medium consisting of skin, adipose and muscle layer. The optical properties of each layer are chosen from the reported data and the absorption coefficient of muscle is rectified by using experimental results. The thickness of adipose layer is varied from 0 - 15 mm and the partial optical pathlength in the muscle layer and the spatial sensitivity profile are predicted by Monte Carlo simulation. The spatial sensitivity profile tends to distribute in the adipose layer and the detected light only grazes the muscle layer. These results suggest that the sensitivity in oxygenation of muscle tissue is impaired by influence of the adipose tissue and NIR O2 monitor mainly detects the oxygenation change in shallow region of the muscle layer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Principles, Techniques, and Limitations of Near Infrared Spectroscopy
Ferrari, M., Mottola, L., & Quaresima, V. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-031 · Cited by 997
Van Beekvelt, M. C. P., Colier, W. N. J. M., Wevers, R. A., & Van Engelen, B. G. M. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.90.2.511 · Cited by 430
Grassi, B., Pogliaghi, S., Rampichini, S., Quaresima, V., Ferrari, M., Marconi, C., & Cerretelli, P. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00695.2002 · Cited by 429
Prefrontal cortex oxygenation and neuromuscular responses to exhaustive exercise
Thomas, R., & Stephane, P. (2007) · European Journal of Applied Physiology · doi:10.1007/s00421-007-0568-7 · Cited by 244
Muscle Deoxygenation and Neural Drive to the Muscle during Repeated Sprint Cycling
RACINAIS, S., BISHOP, D., DENIS, R., LATTIER, G., MENDEZ-VILLANEUVA, A., & PERREY, S. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000251775.46460.cb · Cited by 179
Muscle Oxygenation Trends During Dynamic Exercise Measured by Near Infrared Spectroscopy
Bhambhani, Y. N. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-033 · Cited by 149
“These findings have been supported by other researchers (Homma et al., 1996; Matsushita et al., 1998; Yamamoto et al., 1996; 1998) who have demonstrated reduced tissue absorbency with increasing levels of adipose tissue thickness.”
Result(2006) · PubMed · Cited by 89
Which common NIRS variable reflects muscle estimated lactate threshold most closely?
Wang, L., Yoshikawa, T., Hara, T., Nakao, H., Suzuki, T., & Fujimoto, S. (2006) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/h06-069 · Cited by 54
“5 cm (Matsushita et al. 1998).”
Quaresima, V., Ferrari, M., Franceschini, M. A., Hoimes, M. L., & Fantini, S. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1646417 · Cited by 45
Muscle deoxygenation of upper-limb muscles during progressive arm-cranking exercise
Lusina, S.-J. C., Warburton, D. E. R., Hatfield, N. G., & Sheel, A. W. (2008) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/h07-156 · Cited by 18
Metadata
- Authors
- Matsushita, K., Homma, S., & Okada, E.
- Venue
- SPIE Proceedings
- Publisher
- SPIE
- Published
- 1998-01-01
- Volume
- 3194
- Pages
- 159-165
- ISSN
- 0277-786X (ISSN-L)
- OpenAlex
- W2026212812
- Cited by
- 57
- References
- 0
- FWCI
- 6.35
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.